Artificial joints are used when joints lose their function because of either the destruction or damage of the composing bones of the joints. To evaluate the primary stability of a femur-implant system, the relative displacement caused by a repeated load is measured immediately after the insertion of the artificial joint. For more accurate stability evaluation, the accurate measurement of the penetration displacement of the artificial joint to the bone and the rotation angle of the artificial joint is essential. In this study, to evaluate the primary stability of the femur-implant system, we propose a new relative displacement measurement method. By using this new method, we comparatively evaluate the primary stability for various surgical methods and the varying stiffness of the cadaver femur-implant itself.
Keywords
Implant; Stability Test; Artificial Joint;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Tschegg, E. K., Herndler, S., Weninger, P., Jamek, M., Stanzl-Tschegg, S. and Redl, H., 2008, "Stiffness Analysis of Tibia-Implant System Under Cyclic Loading," Materials Science And Engineering(C), Vol. 28, pp. 1203-1208.   DOI   ScienceOn
2 Gotze, C., Steens, W., Vieth, V., Poremba, C., Claes, L. and Steinbeck, J., 2002, "Primary Stability in Cementless Femoral Stems: Custom-Made Versus Conventional Femoral Prosthesis," Clinical Biomechanics, Vol. 17, pp. 267-273.   DOI   ScienceOn
3 Speirs, A. D., Slomczykowski, M. A., Orr, T. E., Siebenrock, K. and Nolte, L. P., 2000, "Three-Dimensional Measurement Of Cemented Femoral Stem Stability: An in Vitro Cadaver Study," Clinical Biomechanics, Vol. 15, pp. 248-255.   DOI   ScienceOn
4 Stea, S., Bordini, B., Sudanese, A. and Toni, A., 2002, "Registration of Hip Prostheses at the Rizzoli Institute 11 Years' Experience," Acta Orthopaedica Scandinavica, Vol. 73 (Suppl.), pp. 40-44.
5 Marco, V., Giovanni, B., Alberto, P. and Luca, C., 2005, "Primary Stability of an Anatomical Cementless Hip Stem: Astatistical Analysis," Journal of Biomechanics, Vol. 39, pp. 1169-1179.
6 ASTM F1440-92, 2002, "Standard Practice for Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components Without Torsion," Annual Book of ASTM Standards, Vol. 13. 01, pp. 591-596.
7 ASTM F1814-97a, 2003, "Standard Guide for Evaluating Modular Hip and Knee Joint Components," Annual Book of ASTM Standards, Vol. 13. 01, pp. 868-872.
8 ISO 7206, "Implants for Surgery-Partial and Total Hip Joint Prosthesis," Part 4, Part 6, Part 8.