• 제목/요약/키워드: Cad1-3

검색결과 872건 처리시간 0.028초

효율적인 복합다양체 CAD 시스템 위상 작업자 구현 (Implementation of Topological Operators for the Effective Non-manifold CAD System)

  • 최국헌
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.382-387
    • /
    • 2004
  • As the increasing needs in the industrial filed, many studies for the 3D CAD system are carried out. There are two types of 3D CAD system. One is manifold modeler, the other is non-manifold modeler. In the manifold modeler only 3D objects can be modeled. In the non-manifold modeler 3D, 2D, 1D, and 0D objects can be modeled in a unified data structure. Recently there are many studies on the non-manifold modeler. Most of them are focused on finding unknown topological entities and representing all kinds of topological entities found. In this paper, efficient data structure is selected. The boundary information on a face and an edge is included in this data structure. The boundary information on a vertex is excluded considering the frequency of usage. Because the disk cycle information is not required in most case of modeling. It is compact. It stores essential non-manifold information such as loop cycle and radial cycle. A suitable Euler-Poincare equation is studied and selected. Using the efficient data structure and the selected Euler-Poincare equation, 18 basic Euler operators are implemented. Several 3D models are created using the implemented modeler. A non-manifold modeling can be carried out using the implemented 3D CAD system. The results of this paper could be used in the further studies such as an implementation of Boolean operators, and a translation of 2D CAD drawings to 3D models.

  • PDF

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

  • Goracci, Cecilia;Ozcan, Mutlu;Franchi, Lorenzo;Di Bello, Giuseppe;Louca, Chris;Vichi, Alessandro
    • 대한치과교정학회지
    • /
    • 제49권6호
    • /
    • pp.404-412
    • /
    • 2019
  • Objective: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods: Two types of PMMA blocks were tested: $CAD-Temp^{(R)}$ (VITA) and $Telio^{(R)}$ CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) $CAD-Temp^{(R)}/SU$; (2) $CAD-Temp^{(R)}/AP$; (3) $CAD-Temp^{(R)}/XTP$; (4) $Telio^{(R)}$ CAD/SU; (5) $Telio^{(R)}$ CAD/AP; (6) $Telio^{(R)}$ CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit ($100{\mu}m$) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results: On $CAD-Temp^{(R)}$ significantly higher bracket bond strengths than on $Telio^{(R)}$ CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.

3D Model Compression For Collaborative Design

  • Liu, Jun;Wang, Qifu;Huang, Zhengdong;Chen, Liping;Liu, Yunhua
    • International Journal of CAD/CAM
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 2007
  • The compression of CAD models is a key technology for realizing Internet-based collaborative product development because big model sizes often prohibit us to achieve a rapid product information transmission. Although there exist some algorithms for compressing discrete CAD models, original precise CAD models are focused on in this paper. Here, the characteristics of hierarchical structures in CAD models and the distribution of their redundant data are exploited for developing a novel data encoding method. In the method, different encoding rules are applied to different types of data. Geometric data is a major concern for reducing model sizes. For geometric data, the control points of B-spline curves and surfaces are compressed with the second-order predictions in a local coordinate system. Based on analysis to the distortion induced by quantization, an efficient method for computation of the distortion is provided. The results indicate that the data size of CAD models can be decreased efficiently after compressed with the proposed method.

3D CAD System에 의한 안동포의류제품 패턴설계 (Andongpo Apparel Pattern Design Connected with the 3D Apparel CAD System)

  • 김희숙
    • 한국의류산업학회지
    • /
    • 제11권1호
    • /
    • pp.112-120
    • /
    • 2009
  • The purpose of this study is to develop Andongpo apparel pattern design connected with the Apparel CAD system. It includes pattern making, grading, marking program. In this study, it will be able to make apparel pattern quickly and accurately by using Apparel CAD system. The results were as following : Computerization of the pattern making process is expected to provide higher accuracy and efficiency in apparel pattern making for narrow and expensive Andongpo. ESMOD pattern making method was selected as basic pattern. Tailored jacket patterns were developed for Andongpo. Refer to and . The jacket patterns developed is automatically depicted by inputting consumer's body size. Tailored jacket patterns for Andongpo were marked by using marking program in Apparel CAD system. The efficiency of marking appeared of 70% or more in Andongpo jacket patterns. This results is showed it has an effect on narrow and expensive Andongpo. 3tailored jacket patterns will be able to make a simulation by 3D Apparel CAD system. The results of this study is expected to provide higher consumer's satisfaction and internet brand launching. In addition, encouraging majority of the young to participate in using CAD program for Andongpo is regarded as beneficial for the reinforcement of competitiveness of traditional clothing business.

Repair bond strength of resin composite to three aged CAD/CAM blocks using different repair systems

  • Gul, Pinar;Altinok-Uygun, Latife
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.131-139
    • /
    • 2020
  • PURPOSE. The purpose of this study is to evaluate the repair bond strength of a nanohybrid resin composite to three CAD/CAM blocks using different intraoral ceramic repair systems. MATERIALS AND METHODS. Three CAD/CAM blocks (Lava Ultimate, Cerasmart, and Vitablocks Mark II) were selected for the study. Thirty-two specimens were fabricated from each block. Specimens were randomly divided into eight groups for the following different intraoral repair systems: Group 1: control group (no treatment); Group 2: 34.5% phosphoric acid etching; Group 3: CoJet System; Group 4: Z-Prime Plus System; Group 5: GC Repair System; Group 6: Cimara System; Group 7: Porcelain Repair System; and Group 8: Clearfil Repair System. Then, nanohybrid resin composite (Tetric Evo Ceram) was packed onto treated blocks surfaces. The specimens were thermocycled before application of repair systems and after application of composite resin. After second thermal cycling, blocks were cut into bars (1 × 1 × 12 ㎣) for microtensile bond strength tests. Data were analyzed using two-way ANOVA and Tukey's HSD test (α=.05). RESULTS. Cimara System, Porcelain Repair, and Clearfil Repair systems significantly increased the bond strength of nanohybrid resin composite to all CAD/CAM blocks when compared with the other tested repair systems (P<.05). In terms of CAD/CAM blocks, the lowest values were observed in Vitablocks Mark II groups (P<.05). CONCLUSION. All repair systems used in the study exhibited clinically acceptable bond strength and can be recommended for clinical use.

Positive Predictive Values of Abnormality Scores From a Commercial Artificial Intelligence-Based Computer-Aided Diagnosis for Mammography

  • Si Eun Lee;Hanpyo Hong;Eun-Kyung Kim
    • Korean Journal of Radiology
    • /
    • 제25권4호
    • /
    • pp.343-350
    • /
    • 2024
  • Objective: Artificial intelligence-based computer-aided diagnosis (AI-CAD) is increasingly used in mammography. While the continuous scores of AI-CAD have been related to malignancy risk, the understanding of how to interpret and apply these scores remains limited. We investigated the positive predictive values (PPVs) of the abnormality scores generated by a deep learning-based commercial AI-CAD system and analyzed them in relation to clinical and radiological findings. Materials and Methods: From March 2020 to May 2022, 656 breasts from 599 women (mean age 52.6 ± 11.5 years, including 0.6% [4/599] high-risk women) who underwent mammography and received positive AI-CAD results (Lunit Insight MMG, abnormality score ≥ 10) were retrospectively included in this study. Univariable and multivariable analyses were performed to evaluate the associations between the AI-CAD abnormality scores and clinical and radiological factors. The breasts were subdivided according to the abnormality scores into groups 1 (10-49), 2 (50-69), 3 (70-89), and 4 (90-100) using the optimal binning method. The PPVs were calculated for all breasts and subgroups. Results: Diagnostic indications and positive imaging findings by radiologists were associated with higher abnormality scores in the multivariable regression analysis. The overall PPV of AI-CAD was 32.5% (213/656) for all breasts, including 213 breast cancers, 129 breasts with benign biopsy results, and 314 breasts with benign outcomes in the follow-up or diagnostic studies. In the screening mammography subgroup, the PPVs were 18.6% (58/312) overall and 5.1% (12/235), 29.0% (9/31), 57.9% (11/19), and 96.3% (26/27) for score groups 1, 2, 3, and 4, respectively. The PPVs were significantly higher in women with diagnostic indications (45.1% [155/344]), palpability (51.9% [149/287]), fatty breasts (61.2% [60/98]), and certain imaging findings (masses with or without calcifications and distortion). Conclusion: PPV increased with increasing AI-CAD abnormality scores. The PPVs of AI-CAD satisfied the acceptable PPV range according to Breast Imaging-Reporting and Data System for screening mammography and were higher for diagnostic mammography.

임상가를 위한 특집 1 - 턱교정수술에서3D simulation과 CAD/CAM의 활용 (3D simulation and CAD/CAM in orthognathic surgery)

  • 진임건;양훈주;김대승;이원진;황순정
    • 대한치과의사협회지
    • /
    • 제50권11호
    • /
    • pp.660-669
    • /
    • 2012
  • We describes the process of 3D virtual treatment planning and of CAD/CAM for surgical splint in orthognathic surgery. The potential benefits and disadvantages of 3D virtual approach and the use of CAD/CAM system for the treatment of the patient with a maxillofacial deformity are discussed. For the more convenient applications,3D software should be improved.

CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교 (Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins)

  • 이동형;이준석
    • 구강회복응용과학지
    • /
    • 제36권3호
    • /
    • pp.183-195
    • /
    • 2020
  • 목적: 이 논문의 목적은 CAD/CAM 의치상 레진과 열중합 의치상 레진의 굴곡 강도를 비교해보고, 두께에 따른 굴곡 강도 변화도 비교해보는 것이다. 연구 재료 및 방법: 열중합 의치상 레진은 Lucitone 199® (C-LC)을 사용하였다. 3D printing 의치상 레진으로는 DIOnavi - Denture (P-DO)와 DENTCA - Denture Base II (P-DC)를 사용하였다. 밀링 PMMA 블록으로는 Vipi Block Gum (M-VP)과 M-IVoBase® CAD (M-IV)를 사용하였다. 시편의 최종 규격은 65.0 mm × 12.7 mm × 1.6 mm / 2.0 mm / 2.5 mm였다. 굴곡 강도와 굴곡 탄성율을 측정하기 위해 3점 굽힘 시험을 실시하였다. 그리고 파절된 시편의 단면을 주사전자현미경 (SEM) 을 사용하여 분석하였다. 데이터의 정규성을 확인한 뒤 일원분산분석(one-way ANOVA)을 사용하여 유의 수준 P = 0.05로 설정하여 그룹 간의 차이를 평가한 뒤, 사후 분석을 위해 Tukey HSD test를 시행하였다. 결과: 동일 두께 내에서, P-DO를 제외한 나머지 CAD/CAM 의치상 레진들과 열중합 의치상 레진의 굴곡 강도는 유의한 차이를 나타내었다. M-VP는 열중합 의치상 레진 보다 굴곡 강도가 높게 나타났고, P-DC와 M-IV는 낮은 굴곡 강도를 보였다. 굴곡 탄성률은 M-VP에서 제일 높게 나타났고 C-LC, P-DO, P-DC, M-IV 순으로 낮아졌으며 재료간에 모두 유의한 차이가 나타났다. 두께에 따른 굴곡 강도는, C-LC에서는 2.5 mm가 1.6 mm보다 유의하게 높은 굴곡 강도를 보였고, P-DC, M-VP는 2.5 mm와 2.0 mm에서 1.6 mm보다 유의하게 높은 굴곡 강도가 나타났다. M-IV에서는 두께가 증가할수록 유의한 굴곡 강도 증가가 나타났다. SEM 분석 결과 서로 다른 재료들의 파절된 단면은 각기 다른 양상을 띄었다. 결론: 본 연구에서 사용된 CAD/CAM 의치상 레진의 굴곡 강도는 각 재료의 성분 및 특성에 따라 다양하게 나타났다. CAD/CAM 의치상 레진의 굴곡 강도는 두께가 감소하여도 1.6 mm 이상의 두께에서는 ISO 20795-1:2013에서 제시하는 굴곡 강도보다 높게 나타났다. 하지만 보다 얇은 두께의 의치를 임상적으로 사용하기 위해서는, 더 낮은 두께의 의치상 레진의 다른 특성들에 관한 추가적인 연구가 필요하다.

CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교 (Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth)

  • 옹승환;김종수;김종빈;신지선;유승훈
    • 대한소아치과학회지
    • /
    • 제47권2호
    • /
    • pp.205-212
    • /
    • 2020
  • 이 연구의 목적은 파절강도와 반투명도 측정을 통해 Computer Aided Design/Computer Aided Manufacturing (CAD/CAM)으로 제작한 유전치 지르코니아 전장관의 임상적 적용 가능성을 확인하는 것이다. 기성 유전치 모형 중 #61을 스캔하여 얻은 3차원 형상 데이터로 CAD 디자인 프로그램을 이용하여 전장관을 디자인하고, 지르코니아 블록으로 CAM 밀링 기계를 이용하여 전장관을 제작하였다. 지르코니아 전장관은 두께에 따라 0.3, 0.5, 그리고 0.7 mm의 3군으로 나누어 1.0 mm 두께의 레진 전장관과 파절강도를 비교하였다. 파절강도는 만능시험기를 이용하여 30° 각도에서 1 mm/min 속도로 절단면에 하중을 가하여 측정하였다. 반투명도는 가로와 세로가 7.0 mm, 그리고 두께가 각각 0.3, 0.5, 0.7 mm 인 사각형 지르코니아 시편을 제작하여 분광측색장치로 측정하였다. 파절강도 측정 결과 지르코니아 전장관은 두께가 증가할수록 파절강도가 높아졌으며 모든 두께의 지르코니아 군에서 대조군인 레진 전장관보다 파절강도가 높았다(p < 0.05). 반투명도는 0.3 mm 군에서 가장 높았으며 0.5, 0.7 mm로 두께가 증가할수록 감소하였다(p < 0.05). CAD/CAM으로 제작한 지르코니아 전장관은 개별 치아에 맞추어 얇게 디자인 및 제작 가능하며, 얇은 전장관을 이용한 수복은 임상적으로 치아 삭제량과 치수노출 위험성 감소 뿐만 아니라, 더 심미적인 수복을 가능하게 해줄 것이다.

이 기종 시스템간의 CAD 데이터 교환 (CAD Data Exchange among Different Commercial Packages)

  • 김태욱;황병억
    • 한국산업융합학회 논문집
    • /
    • 제7권4호
    • /
    • pp.377-382
    • /
    • 2004
  • This research was about implementing STEP for data exchange among different commercial package(CAD system). STEP was used to share CAD data as follows. ST-Developer implement Solid model was used with a physical file of STEP and represented in a CAD system. And then STEP conversion utility was used to make a neutrality format form in a component modeling. Analysis of Solid model was made possible for CAD system to read in and analyzed Solid model. This research are summarized as follows 1. A basis Model development used Visual C++ for a neutrality data of a programming interface general-use CAD system, and produced Box and Cylinder to a physical file, the result was implemented this in a programming interface to general-use CAD system, it is represented in CAD system as identical one modeling object. 2. STEP was used in different CAD system to utilize to its of each CAD system maximum, CATIA V5R9 user was able to analyze MDT 6 Modeling Arm. 3. STEP was used able to interpret and remodel the existing Solid model.

  • PDF