• Title/Summary/Keyword: Cad1-3

Search Result 872, Processing Time 0.034 seconds

Studies on immobilization and application of beta-galactosidase II. Preparation and properties of the immobilized enzyme from Aspergillus niger CAD 1 (beta-Galaetosidase의 고정화 및 응용에 관한 연구 제2보: Aspergillus niger CAD 1의 효소 교정화 조건 및 고정화 효소의 성질)

  • Lee, Yong-Kyu;Cuun, Soon-Bae;Choi, Won-Ki;Chung, Ki-Chul;Bae, Suk;Kim, Kwan-Chun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.4
    • /
    • pp.40-46
    • /
    • 1986
  • The beta-galactosidase of Aspergillus niger CAD 1 described in previous report was immobilized to cellulose triacetate. The optimal conditions for immobilization of the enzyme were obtained when 13%(v/v) of the soluble enzyme (349 unit/ml) was entrapped in fiber prepared from 10%(w/v) cellulose triacetate in methylene chloride. The optimal temperature and pH for the activity of the immobilized enzyme were $45^{\circ}C$ and 4.5, respectively, which stowed the same values as those of the soluble enzyme. It was found that Km of the immobilized enzyme for lacotse exhibited high value compared with that of the soluble enzyme. The immobilized enzyme showed good storage stability, reusability, and also hydrolysis of lactose when introduced into skim milk and acidic whey.

  • PDF

A Protocol Analysis on the Characteristics of CAD Modeler to Aid Architectural Massing Education (건축형태구상교육을 위한 3차원 CAD모델러의 특성에 따른 프로토를 분석연구)

  • Hong S.-W.;Lee K.-H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.4
    • /
    • pp.293-302
    • /
    • 2005
  • The research focused quantitative comparisons of protocols occurring in the architectural massing process using two different tools, three-dimensional(3D) modeler and traditional design tools, to aid architectural massing education. Through the protocol analysis from some experiments, the research identified the following conclusions: 1) Usage of traditional tools produced much higher protocol rate in proposing solution, evaluating proposed solution, explicitness of strategies. This result seemed to be from convenience of traditional tools causing faster visual cognitive cycle. 2) Usage of 3D modeler produced much higher protocol rate concerning attempts of making design vocabulary. The result indicated 3D modeler has relatively effective functions for mass generation and orientation, however it still has some weaknesses on display interface which cause designer's lower idea generations compared to traditional design tools.

Group Action Recognition through Grid search and Transformer (Grid search와 Transformer를 통한 그룹 행동 인식)

  • Gi-Duk Kim;Geun-Hoo Lee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.513-515
    • /
    • 2023
  • 본 논문에서는 그리드 탐색과 트랜스포머를 사용한 그룹 행동 인식 모델을 제안한다. 추출된 여러 사람의 스켈레톤 정보를 차분 벡터, 변위 벡터, 관계 벡터로 변환하고 사람별로 묶어 이를 TimeDistributed 함수에 넣고 풀링을 한다. 이를 트랜스포머 모델의 입력으로 넣고 그룹 행동 인식 분류를 출력하였다. 논문에서 3가지 벡터를 입력으로 하여 합치고 트랜스포머 계층을 거친 모델과 3가지 벡터를 입력으로 하고 계층적으로 트랜스포머 모델을 거쳐 행동 인식 분류를 출력하는 두 가지 모델을 제안한다. 3가지 벡터를 합친 모델에서 클래스 분류 정확도는 CAD 데이터 세트 96.6%, Volleyball 데이터 세트 91.4%, 계층적 트랜스포머 모델은 CAD 데이터 세트 96.8%, Volleyball 데이터 세트 91.1%를 얻었다

  • PDF

Comparison of the Marginal and Internal Fit on the Cast and CAD-CAM Cores (주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가)

  • Han, Man-So;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.368-374
    • /
    • 2012
  • Dental CAD (computer-aided design)/CAM (computer-aided manufacturing) systems facilitate the use of zirconia core for all-ceramic crown. The purpose of this study was to evaluate the marginal and internal fit of zirconia core fabricated using a dental CAD/CAM system and to compare the fit of metal cores by a conventional method. Ten identical cases of single coping study models (abutment of teeth 11) were manufactured and scanned. Ten zirconia cores were fabricated using dental CAD/CAM system. An experienced dental technician fabricated 10 samples of metal cores for the control group using the lost wax technique. Marginal and internal fit was measured by the silicone replica technique. Fit was measured with magnification of 160 using a digital Microscope. Margin, rounded chamfer, axial wall and incisal fits were measured for comparison. T-test of independent sample for statistical analysis was executed with SPSS 12.0 for Windows (SPSS Inc., Chicago, IL, USA) (${\alpha}$=0.05). The mean (SD) for marginal, rounded chamfer, axial wall and incisal were: $97.0\;(25.3){\mu}m$, $104.0\;(22.0){\mu}m$, $59.6\;(21.4){\mu}m$ and $124.8\;(33.3){\mu}m$ for the zirconia core group, and $785.2\;(18.4){\mu}m$, $83.8\;(15.1){\mu}m$, $42.7\;(9.6){\mu}m$ and $83.4\;(14.4){\mu}m$ for the metal core group. T-test showed significant differences between groups for margin (p<.001), rounded chamfer (p<.001), axial wall (p<.001) and incisal (p<.001). But zirconia core group observed that the marginal and internal fit values in the present study were within clinically acceptable range.

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

A CAD/CAM-based strategy for concurrent endodontic and restorative treatment

  • Escobar, Patricia Maria;Kishen, Anil;Lopes, Fabiane Carneiro;Borges, Caroline Cristina;Kegler, Eugenio Gabriel;Sousa-Neto, Manoel Damiao
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.27.1-27.12
    • /
    • 2019
  • This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.

Factors Associated with Sleep Quality in Patients with Coronary Artery Disease (관상동맥질환자의 수면의 질과 관련요인)

  • Lee, Su-Jin;Hwang, Sun-Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.15-27
    • /
    • 2023
  • Purpose : This study aimed to examine the relationship between sleep quality and its influencing factors in patients with coronary artery disease (CAD). Methods : This descriptive correlational study included 130 patients with CAD admitted to the cardiology department of a general hospital in B City between September 2019 and February 2020. Data were collected using structured questionnaires and research instruments to measure sleep quality, anxiety, depression, chronotype, and daytime sleepiness. Results : The mean scores for sleep quality, daytime sleepiness, anxiety, and depression were 7.59±3.45, 6.45±3.46, 6.58±3.88, and 7.74±4.05, respectively. In terms of chronotypes, 10.8%, 48.5%, and 40.7% of the participants had evening-, intermediate-, and morning-type patterns, respectively. Sleep quality was significantly correlated with anxiety (r=0.38, p<.001), depression (r=.37, p<.001), and daytime sleepiness (r=.26, p =.002). Factors associated with sleep quality in patients with CAD included anxiety (β=.29), heart failure (β=.22), daytime sleepiness(β=.21), and sleeping alone (β=.19). Collectively, these factors had an explanatory power of 23.1% for sleep quality variance. Conclusion: Patients with CAD often experience poor sleep quality owing to various factors such as anxiety, daytime sleepiness, heart failure, and sleeping alone. It is recommended that healthcare providers objectively evaluate sleep and identify factors that influence sleep quality. This will enable the development of effective methods for sleep management as part of nursing care.

Structure of Tetra-ter-butyl-tetrapropionyloxycalix[4]arene (Tetra-tert-butyl-tstrapropionyloxycalix [4] arene의 구조)

  • 김회진;노광현
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • Tetra-tert-butyl-tetrapropionycalix (4) arena (C56H7208) is Triclinic, space group Pl, with a=13.664(5), b=17.585(5), c=12.863(2)A, a=109.33(2), B=111.97(2), γ=76.45(3) ˚, Z=2, V=2684.08A3, D, =1.152g/cm3, Dm=1.15g/cm3. The intensity data were collected on an Enraf-Nonius CAD-4 Diffractometer with a graphite monochromated Mo-Ka radiation. The structure was solved by direct methods and refined by leastsquares methods. The final R factor was 0.084 for 2561 observed reflections. The configuration of the molecule from the X-ray crystallographic investigation has the partial cone conformation, three tort-butylphenyls are down and a tort-butylphenyl is up. Three propionyloxy groups direct toward the exterior of the macrocycle cavity.

  • PDF

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.