• Title/Summary/Keyword: CTA

Search Result 214, Processing Time 0.037 seconds

Preparation of Acryl Binder with Silane Type Chain Transfer Agent (실란계 사슬 이동제를 사용한 아크릴 바인더의 제조)

  • Kim, Jin-Gon;Shin, Min-Jae;Shin, Jae-Sup
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.351-356
    • /
    • 2012
  • Acryl binder is a representative organic additive for the manufacture of the display electronic equipment. Acryl binder is usually synthesized by radical copolymerization. Glycidyl methacrylate (GMA), methyl methacrylate (MMA), and methacrylic acid (MAA) were used in this copolymerization of acryl binder. In this study the silane type mercaptane compound was used as a chain transfer agent (CTA) to enhance the adhesion property of the acrylic binder. The CTA used in this experiment was (3-mercaptopropyl) trimethoxysilane (MPTMS). Molecular weight of the copolymer, thickness of the coating, transmittance, and adhesion property were measured. The molecular weight was controlled and the adhesion property was improved by using this silane type chain transfer agent.

A Rotating Chamber Mechanism and Its Controller for CTA Guns (CTA 자동포용 회전 약실 기구 및 제어기)

  • Lim, S.;Kim, K.K.;Shim, J.S.;Kil, S.J.;Lee, G.H.;Cha, G.U.;Cho, C.K.;Hong, S.K.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.50-59
    • /
    • 2006
  • Lately, there exist growing demands for the use of CTAs(Cased Telescoped Ammunitions) to increase the firepower of mid-calibre automatic guns despite spatial limitations of armament. In this paper, for automatic CTA guns a rotating chamber mechanism is designed based on parallel index concept. Via dynamic simulations it proves capable of smooth operation even at as high a firing rate as 200spm. Subsequently, motor controllers are synthesized to drive the chamber at any constant speed and also to control positions in the presence of large disturbances caused by the intermittently-rotating load. It is remarkable that we successfully adopted a disturbance observer to treat disturbances only with a moderate bandwidth of the closed-loop system.

Unscented Kalman Snake for 3D Vessel Tracking

  • Lee, Sang-Hoon;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose In this paper, we propose a robust 3D vessel tracking algorithm by utilizing an active contour model and unscented Kalman filter which are the two representative algorithms on segmentation and tracking. Materials and Methods The proposed algorithm firstly accepts user input to produce an initial estimate of vessel boundary segmentation. On each Computed Tomography Angiography (CTA) slice, the active contour is applied to segment the vessel boundary. After that, the estimation process of the unscented Kalman filter is applied to track the vessel boundary of the current slice to estimate the inter-slice vessel position translation and shape deformation. Finally both active contour and unscented Kalman filter are inter-operated for vessel segmentation of the next slice. Results The arbitrarily shaped blood vessel boundary on each slice is segmented by using the active contour model, and the Kalman filter is employed to track the translation and shape deformation between CTA slices. The proposed algorithm is applied to the 3D visualization of chest CTA images using graphics hardware. Conclusion Through this algorithm, more opportunities, giving quick and brief diagnosis, could be provided for the radiologist before detailed diagnosis using 2D CTA slices, Also, for the surgeon, the algorithm could be used for surgical planning, simulation, navigation and rehearsal, and is expected to be applied to highly valuable applications for more accurate 3D vessel tracking and rendering.

Protective effects of Opuntia ficus-indica on Glutathione and Antioxidative Enzyme (Opuntia ficus-indica가 Glutathione 및 항산화 효소에 미치는 보호효과)

  • 전홍기;정영기;하배진
    • Journal of Life Science
    • /
    • v.13 no.6
    • /
    • pp.911-916
    • /
    • 2003
  • The effects of Opuntia ficus-indica (OF) administration on the biochemical parameters of function in liver tissue and serum of $CCl_4$ treated rats were investigated. Opuntia ficus-indica (200 mg/kg) was administered into rats intraperitoneally for two weeks. $3.3m\ell$ of $CCl_4$$_4$ (50% $CCl_4$ : Olive oil = 1 : 1) was treated to rats on the 14th day and 15th day and they were operated on 15th day. We examined the antioxidative enzymatic activity by measuring the level of AST (Aspartate aminotransferase), ALT (Alanine aminotransferase), GSH (Glutathione reduced form), GSSG (Glutathione oxidezed form), GPx (GSH-peroxidase), SOD (Superoxide dismutase) and CAT (Catalase) in serum and liver tissue of rats. OFC administered group showed 24.8% of inhibitory effect in AST activity compared to $CCl_4$ -treated abnormal group (CTA). ALT level of OF administered group was decreased by 60.7% to the level of CTA. GSH, GSSG and GPx of OFC administered group were significantly higher than those of CTA group. SOD and CAT in OFC administered group were increased by 28.3% and by 16.9% respectively compared to those of CTA group.

Microwave Annealing을 이용한 MOS Capacitor의 특성 개선

  • Jo, Gwang-Won;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.241.1-241.1
    • /
    • 2013
  • 최근 고집적화된 금속-산화막 반도체 metal oxide semiconductor (MOS) 소자는 크기가 점점 작아짐에 따라 얇은 산화막과 다양한 High-K 물질과 전극에 대하여 연구되고 있다. 이러한 소자의 열적 안정성과 균일성을 얻기 위해 다양한 열처리 방법이 사용되고 있으며, 일반적인 열처리 방법으로는 conventional thermal annealing (CTA)과 rapid thermal annealing (RTA)이 많이 이용되고 있다. 본 실험에서는 microwave radiation에 의한 열처리로 소자의 특성을 개선시킬 수 있다는 사실을 확인하였고, 상대적으로 $100^{\circ}C$ 이하의 저온에서도 공정이 이루어지기 때문에 열에 의한 소자 특성의 열화를 억제할 수 있으며, 또한 짧은 처리 시간 및 공정의 단순화로 비용을 효과적으로 절감할 수 있다. 본 실험에서는 metal-oxide-silicon (MOS) 구조의 capacitor를 제작한 다음, 기존의 CTA나 RTA 처리가 아닌 microwave radiation을 실시하여 MOS capacitor의 전기적인 특성에 미치는 microwave radiation 효과를 평가하였다. 본 실험은 p-type Si 기판에 wet oxidation으로 300 nm 성장된 SiO2 산화막 위에 titanium/aluminium (Ti/Al) 금속 전극을 E-beam evaporator로 형성하여 capacitance-voltage (C-V) 특성 및 current-voltage (I-V) 특성을 평가하였다. 그 결과, microwave 처리를 통해 flat band voltage와 hysteresis 등이 개선되는 것을 확인하였고, microwave radiation 파워와 처리 시간을 최적화하였다. 또한 일반적인 CTA 열처리 소자와 비교하여 유사한 전기적 특성을 확인하였다. 이와 같은 microwave radiation 처리는 매우 낮은 온도에서 공정이 이루어짐에도 불구하고 시료 내에서의 microwave 에너지의 흡수가 CTA나 RTA 공정에서의 열에너지 흡수보다 훨씬 효율적으로 이루어지며, 결과적으로 산화막과 실리콘 기판의 계면 특성 개선에 매우 효과적이라는 것을 나타낸다. 따라서, microwave radiation 처리는 향후 저온공정을 요구하는 nano-scale MOSFET의 제작 및 저온 공정이 필수적인 display 소자 제작의 해결책으로 기대한다.

  • PDF

Microwave와 Solution ZrO2를 이용한 Metal-Oxide-Semiconductor-Capacitor 제작

  • Lee, Seong-Yeong;Kim, Seung-Tae;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.206.1-206.1
    • /
    • 2015
  • 최근에 금속산화물을 증착하는 방법으로 용액공정이 주목 받고 있다. 용액 공정은 대기압에서 매우 간단한 방법으로 복잡한 공정과정을 요구하지 않기 때문에 박막을 경제적으로 간단하게 형성할 수 있다. 하지만 용액공정을 통해 형성한 박막에는 소자의 특성을 열화 시키는 solvent와 탄소계열의 불순물을 많이 포함하고 있어 고온의 열처리가 필수적이다. 박막의 품질을 향상시키기 위해서 다양한 열처리 방법들이 이용되고 있으며, 일반적인 열처리 방법으로는 furnace를 이용한 conventional thermal annealing (CTA)이 많이 이용되고 있다. 하지만, 최근에는 microwave를 이용한 공정이 주목 받고 있다. Microwave energy는 CTA보다 효과적으로 비교적 낮은 온도에서 높은 열처리 효과를 나타낸다. 본 실험은 n-type Silicon 기판에 solution-ZrO2 산화막을 형성 후, oven baking을 한 뒤, CTA와 microwave를 이용하여 solvent와 불순물을 제거 하였다. 전기적 특성을 확인하기 위해 solution ZrO2 산화막 위에 E-beam evaporator를 이용해 Ti 금속 전극을 증착하여 Metal-Oxide-Semiconductor (MOS) capacitor를 제작하였다. 다음으로, PRECISION SEMICONDUCTOR PARAMETER ANALYZER (4156B)를 이용하여, capacitance-voltage (C-V) 특성 및 current-voltage (I-V) 특성을 비교하였다. 다음으로, CTA를 통하여 제작한 소자와 전기적 특성을 비교하였다. 그 결과, Microwave irradiation으로 열처리한 MOS capacitor 소자에서 capacitance 값과 flat band voltage, hysteresis 등이 개선되는 효과를 확인하였다. Microwave irradiation 열처리는 100oC 미만의 온도에서 공정이 이루어짐에도 불구하고 시료 내에서의 microwave 에너지의 흡수가 CTA 공정에서의 열에너지 흡수보다 훨씬 효율적으로 이루어지며, 결과적으로 ZrO2 용액의 불순물과 solvent를 낮은 온도에서 제거하여 고품질 박막 형성에 매우 효과적이라는 것을 나타낸다. 따라서, microwave irradiation 열처리 방법은 비정질 산화막이 포함되는 박막 transistor 소자 제작에 대하여 결정적인 열처리 방법이 될 것으로 기대한다.

  • PDF

Which Emphasizing Factors Are Most Predictive of Hematoma Expansion in Spot Sign Positive Intracerebral Hemorrhage?

  • Kim, So Hyun;Jung, Hyun Ho;Whang, Kum;Kim, Jong Yun;Pyen, Jin Su;Oh, Ji Woong
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.86-90
    • /
    • 2014
  • Objective : The spot sign is related with the risk of hematoma expansion in spontaneous intracerebral hemorrhage (ICH). However, not all spot sign positive patients undergo hematoma expansion. Thus, the present study investigates the specific factors enhancing the spot sign positivity in predicting hematoma expansion. Methods : We retrospectively studied 316 consecutive patients who presented between March 2009 to March 2011 with primary ICH and whose initial computed tomography brain angiography (CTA) was performed at our Emergency Department. Of these patients, 47 primary ICH patients presented spot signs in their CTA. We classified these 47 patients into two groups based on the presence of hematoma expansion then analyzed them with the following factors : gender, age, initial systolic blood pressure, history of anti-platelet therapy, volume and location of hematoma, time interval from symptom onset to initial CTA, spot sign number, axial dimension, and Hounsfield Unit (HU) of spot signs. Results : Of the 47 spot sign positive patients, hematoma expansion occurred in 26 patients (55.3%) while the remaining 21 (44.7%) showed no expansion. The time intervals from symptom onset to initial CTA were $2.42{\pm}1.24$ hours and $3.69{\pm}2.57$ hours for expansion and no expansion, respectively (p=0.031). The HU of spot signs were $192.12{\pm}45.97$ and $151.10{\pm}25.14$ for expansion and no expansion, respectively (p=0.001). Conclusions : The conditions of shorter time from symptom onset to initial CTA and higher HU of spot signs are the emphasizing factors for predicting hematoma expansion in spot sign positive patients.

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

Rapid Rigid Registration Method Between Intra-Operative 2D XA and Pre-operative 3D CTA Images (수술 중 촬영된 2D XA 영상과 수술 전 촬영된 3D CTA 영상의 고속 강체 정합 기법)

  • Park, Taeyong;Shin, Yongbin;Lim, Sunhye;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1454-1464
    • /
    • 2013
  • In this paper, we propose a rapid rigid registration method for the fusion visualization of intra-operative 2D XA and pre-operative 3D CTA images. In this paper, we propose a global movement estimation based on a trilateration for the fast and robust initial registration. In addition, the principal axis of each image is generated and aligned, and the bounding box of the vascular shape is compared for more accurate initial registration. For the fine registration, two images are registered where the distance between two vascular structures is minimized by selective distance measure. In the experiment, we evaluate a speed, accuracy and robustness using five patients' data by comparing the previous registration method. Our proposed method shows that two volumes can be registered at optimal location rapidly, and robustly comparing with the previous method.

Can Computed Tomographic Angiography Be Used to Predict Who Will Not Benefit from Endovascular Treatment in Patients with Acute Ischemic Stroke? The CTA-ABC Score

  • Kwak, Hyo-Sung;Park, Jung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.4
    • /
    • pp.470-476
    • /
    • 2020
  • Objective : The objective of this study was to develop a score to predict patients with acute ischemic stroke (AIS) who will not benefit from endovascular treatment (EVT) using computed tomographic angiography (CTA) parameters. Methods : The CTA-ABC score was developed from 3 scales previously described in the literature: the Alberta Stroke Program Early CT Score (0-5 points, 3; 6-10 points, 0), the clot burden score (0-3 points, 1; 4-10 points, 0), and the leptomeningeal Collateral score (0-1 points, 2; 2-3 points, 0). We evaluated the predictive value of CTA parameters associated with symptomatic intracranial hemorrhage (sICH) or malignant middle cerebral artery infarction (MMCAI) after EVT and developed the score using logistic regression coefficients. The score was then validated. Performance of the score was tested with an area under the receiver operating characteristic curve (AUC-ROC). Results : The derivation cohort consisted of 115 and the validation cohort consisted of 40 AIS patients. The AUC-ROC was 0.97 (95% confidence interval [CI], 0.94-0.99; p<0.001) in the derivation cohort. The proportions of patients with sICH and/or MMCAI in the derivation cohort were 96%, 73%, 6%, and 0% for scores of 6, 5, 1, and 0 points, respectively. In the validation group, the proportions were similar (90%, 100%, 0%, and 0%, respectively) with an AUC-ROC of 0.96 (95% CI, 0.90-1.00; p<0.001). Conclusion : Our CTA-ABC score reliably assessed risk for sICH and/or MMCAI in patients with AIS who underwent EVT. It can support clinical decision-making, especially when the need for EVT is uncertain.