• 제목/요약/키워드: CT-scan

검색결과 1,344건 처리시간 0.025초

두경부 악성종양에서 경부임파절전이에 대한 CT Scan의 진단적 의의 (The Correlation between CT Images and Pathological Findings in Metastatic Cervical Lymph Nodes)

  • 이원상;김광문;정광현;장훈상;김지우;김동익
    • 대한두경부종양학회지
    • /
    • 제4권1호
    • /
    • pp.5-11
    • /
    • 1988
  • CT examination has been used in the preoperative examination of patients with head and neck cancer. The accuracy of CT in detecting nodal metastases has not been well established. We studied 35 patients (41 neck specimens) with head and neck cancer who underwent neck dissection. Surgical pathologic findings were compared with preoperative CT scan to establish the diagnostic accuracy for cervical lymph node metastases. The results of physical examination, CT scans of neck and histologic examinations were compared each other. The overall diagnostic accuracy of CT was 83.3%. Comparison with clinical accuracy shows the CT scan to be superior to the clinical examination in spite of careful physical examination, particularly in detecting occult metastases.

  • PDF

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

Lumbar Spine CT 촬영한 요각통 환자 32례의 치료경과 분석 (The Clinical Analysis on 32 Cases of Herniated Lumbar Disc Patients according to Lumbar CT scan.)

  • 김정호;이정환;김영일
    • 대한약침학회지
    • /
    • 제13권2호
    • /
    • pp.111-120
    • /
    • 2010
  • Objective: This study is to evaluate the effectiveness of the oriental medicine treatment on lumbar disc herniation. Subjects and Methods : The clinical analysis was done on 32 cases of patients with lumbar disc herniation diagnosed by lumbar CT scan. Patients who admitted In Cheongju Oriental Medicine Hospital from April 2007 to April 2008 were analyzed according to the distribution of sex, age, the period of disease, condition on admission, the symptom on admission, Admission day, the treatment efficacy at discharge day. Results : 1. The forties was the most, the acutest phase the most, the day of 8-14 days the most. 2. Multiple bulging disc in 37.5% of CT scan was the most common, followed by a single HNP was 28.1%. 3. Almost 81 % patients showed effective efficacy under VAS 3 at discharge day. 4. Single bulging and herniated disc were more short admission days than multiple bulging and herniated disc.

L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성 (Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT)

  • 고현수;박순기;김은혜;최종숙;정우영;이동윤
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究) (Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques)

  • 이주혁;고경환;하성환;한만청
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로 (Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital)

  • 이재승;김현진;임인철
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.290-296
    • /
    • 2015
  • 본 연구는 일개병원에서 시행된 년간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고 준위와 비교하여 분석함으로써 제안점을 도출하고 피폭 방사선량 저감화 방안을 제시하고자 하였다. 이를 위하여 2014년 1월부터 12월까지 두부 손상으로 소아 두부 CT 검사를 의뢰 받은 10세 미만의 소아 231명을 후향적으로 조사하였다. 조사 방법은 선량 보고서와 의료전자차트를 참조하여 일반적 특성, 관전압(kVp), 관전류(mA), 검사 범위, $CTDI_{vol}$, DLP를 조사하여 분석하였다. 결과적으로 $CTDI_{vol}$은 전체 연구대상자의 7.4%(17명)가 국내 진단참고준위를 초과한 것으로 나타났으며 DLP의 경우 41.6%(96명)가 초과 되어 $CTDI_{vol}$ 보다 비교적 높게 나타났다. DLP는 한국식품의약품안전처에서 제시한 CT 선량 지표보다 대부분 약 60% 이상 초과되었으며 건강보험심사평가원에서 제시한 기준 검사 범위보다 약 30%이상 증가된 검사 범위가 DLP가 높게 나타난 원인으로 분석되었다. 결론적으로 임상에서 CT 검사 시 건강보험심사 평가원에서 제시하는 소아 두부 CT 검사의 기준 검사 범위를 준수하여 검사하고 프로토콜을 적절히 조절한다면 피폭선량을 상당히 낮출 수 있을 것으로 판단된다.

두경부악성종양(頭頸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관(關)한 연구(硏究) (Efficacy of CT-aided Radiotherapy Planning of Head and Neck Tumor)

  • 조철구;고경환;장기현;박찬일
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1983
  • CT scans obtained on 15 patients of head and neck malignant tumors were evaluated for their utility in ratiotherapy treatment planning. To evaluate the advantage of incorporating CT scans in radiotherapy treatment planning of head and neck malignant tumors, the dose distributions of treatment plan with and without CT scan were compared in 15 patients. And then the dose distributions of the first and second treatment plan were compared. 1. Tumor extend and localization were clearly delineated on CT scan in 12 of 15 cases (80%), suggestive in 2 (13.3%), and not seen in only one (6.7%) which had been in the postoperative state. 2. Tumor coverage after CT scan was adequate in 14 of 15 cases (93.3%) and not in only one. In one case of inadequate tumor coverage the target volume lay inside the field but reached within 0.5cm of the field margin (marginal miss). 3. The volume of normal tissue irradiated was reduced after CT scan in 12 of 15 cases (80%), increased in 1 (6.7%) and not changed in 2 (13.3%). 4. We could maximize the local control of disease and minimize unnecessary morbidity by delineating the location and extent of tumor and normal tissue with CT for treatment plannings.

  • PDF

개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합 (Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis)

  • 박용휘
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구 (Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT)

  • 강은보
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.47-52
    • /
    • 2018
  • Brain Perfusion CT는 시간적 제약을 많이 받는 허혈성 급성뇌경색 환자의 관류 상태에 대한 정보를 정확하고 신속하게 제공함으로써 적절한 치료를 하는데 유용한 촬영 기법으로 임상에서 많이 촬영되고 있다. 그러나 이런 장점에도 불구하고 수정체의 피폭선량이 아주 많다는 단점이 있다. 본 연구에서는 Brain Perfusion CT 검사 시 수정체 피폭선량을 최대한 감소시키기 위한 방법으로 Bismuth 차폐체와 Position의 변화를 통하여 수정체 피폭선량의 최소화 방안을 알아보기 위한 목적으로 본 실험을 진행하였다. 팬텀(PBU-50)을 사용하여 양쪽 수정체에 TLD(TLD-100)를 올려두고 IOML에 평행, IOML에 평행(Bismuth 차폐), SOML에 평행, SOML에 평행(Bismuth 차폐)의 총 4가지 Position으로 각각 5회씩 Brain Perfusion scan을 실시하여 수정체의 선량을 측정하였다. 그리고 각각의 Position에 따른 화질 변화를 측정하기 위해 4군데에 관심영역을 정하여 CT Number와 Noise의 변화를 측정하여 비교하였다. 측정된 선량을 일원배치 분산분석한 결과 유의확률 0.000으로 Position에 따라 수정체의 피폭선량에 차이가 있다고 나타났으며, Duncan 사후검정결과에서 IOML에 평행 scan을 기준으로 SOML에 평행 scan과 SOML에 평행 scan(Bismuth 차폐)에서 각각 89.16%, 89.66%로 수정체 선량이 많이 감소하였으며, IOML에 평행 scan(Bismuth 차폐) 에서 37.12%순으로 감소하여 나타났다. 연구 결과 피폭선량은 SOML에 평행한 scan과 Bismuth를 차폐하여 SOML에 평행한 scan이 동일하게 감쇠효과가 가장 크게 나타났다. 수정체의 등가선량 선량한도와 비교하여 IOML에 평행한 scan에서 종사자와 공중의 선량을 기준으로 비교하면 각각 39.47%, 394.73%로 나타났으나, Bismuth를 차폐하여 SOML에 평행한 scan에서 각각 4.08%, 40.8%로 현저하게 줄어 들었다. 화질평가에서 모든 영상의 CT Number와 Noise측정에서 팬텀 영상검사 평가기준에 적합하게 나타났다. Brain Perfusion CT 촬영 시 차폐체를 사용하고 수정체가 조사야에 들어오지 않도록 환자의 position을 조절하는 것이 수정체 피폭을 줄이는 가장 유용한 방법이라 사료된다.