• 제목/요약/키워드: CT subtraction technique

검색결과 9건 처리시간 0.027초

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • 제24권5호
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

CT 혈관 조영 영상에서 뼈 소거법 기반의 하지 혈관 자동 추출 (Automatic Lower Extremity Vessel Extraction based on Bone Elimination Technique in CT Angiography Images)

  • 김수경;홍헬렌
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권12호
    • /
    • pp.967-976
    • /
    • 2009
  • 본 논문에서는 CT 및 CT 혈관 조영 영상에서 강체 정합 및 뼈 소거법을 이용한 하지 혈관 자동 추출 방법을 제안한다. 첫째, 뼈의 부분적인 움직임을 반영하기 위하여 해부학 정보를 바탕으로 하지를 자동 구역화하고, 둘째, CT와 CTA 영상간 움직임을 산정하기 위하여 거리지도 기반의 강체 정합을 수행한다. 셋째, CTA 영상에서 복잡한 구조를 갖는 뼈를 제거하고 뼈에 인접한 혈관이 깎이는 것을 방지하기 위하여 뼈 소거법과 혈관 마스킹 기법을 제안한다. 넷째, 정합오차 및 연골 등의 잡음을 줄이기 위하여 혈관 추적 기반의 후 처리 과정을 통하여 보정한다. 제안 방법의 평가를 위해 육안 평가와 정확성 평가 그리고 수행시간을 측정하였다. 육안 평가를 위해 차감 기법, 정합 후 차감 기법, 제안 방법을 적용한 결과를 볼륨렌더링과 최대 강도 투영영상을 사용하여 비교하였다. 정확성 평가를 위해 CTA 영상과 차감 기반 기법 및 제안 방법을 적용한 결과의 밝기값 분포도를 분석하였다. 실험 결과 뼈는 제거되고 가는 혈관 및 다른 조직의 손실 없이 혈관이 정확하게 추출되었음을 볼 수 있었고, 13명의 환자 데이터 전채에 대한 전체 수행시간은 약 40포 정도로 측정되었다.

자발두개내압저하의 척추 자기공명영상 소견 (Spinal Presentation of Spontaneous Intracranial Hypotension)

  • 류혜진
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.24-35
    • /
    • 2024
  • 자발두개내압저하(spontaneous intracranial hypotension)은 기립성 두통을 특징으로 하는 질환이며, 영상기법의 발달과 질환에 대한 인식이 높아짐에 따라 발견 빈도가 점차 증가하고 있는 추세이다. 이전에는 이 질환에서의 특징적인 뇌 자기공명영상 소견들이 많이 알려져 있었다. 그러나 최근에는 척추에서의 뇌척수액 누출이 원인으로 알려짐에 따라 척추 자기공명영상 소견이 주목받고 있다. 또한 뇌척수액 누출 부위를 정확히 확인할 수 있는 초고속 CT 척수조영술(ultrafast CT myelography), 디지털 감산 척수조영술(digital subtraction myelography) 등이 개발되었다. 이 종설에서는 자발두개내압저하의 진단, 척추 자기공명영상 소견, 최신 영상검사법과 치료에 대해 다루고자 한다.

뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식 (Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.961-968
    • /
    • 2019
  • 본 연구는 CT를 이용한 뇌혈관 추출 검사에서 이중에너지 기법을 활용하여 각 에너지 준위별 뇌혈관 조영술의 유용성을 평가하였다. 방법은 CT 뇌혈관 조영술을 시행한 환자 15명의 DE 영상과 SE 영상을 대상으로 하였다. 영상의 분석은 MCA, 뇌실직 조직, Background에 ROI를 설정하여 평균값, 표준편차 및 SNR, CNR 값을 구하고, SE영상과 비슷하게 구현되는 에너지 영역을 알아보았다. Likert 5점 척도 육안평가를 병행한 결과 DE 40 keV와 SE 120 kVp에서 가장 선명한 MCA 영상을 확인 하였다(p>0.05). SE영상의 SNR 값은 DE영상의 40 keV에너지 준위값과 비슷하게 측정되었고, 40 keV와 50 keV의 저에너지 준위의 영상이 SNR이 높게 측정되어 고에너지 준위의 영상에 비해 대조도가 높아 뇌혈관질환을 유용하게 관찰할 수 있을 것으로 사료된다.

Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction

  • Kyungsoo Bae;Dong Yul Oh;Il Dong Yun;Kyung Nyeo Jeon
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.139-149
    • /
    • 2022
  • Objective: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists' performance for pulmonary nodule detection on chest radiographs (CXRs). Materials and Methods: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed. Results: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules. Conclusion: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists' performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required.

높은 칼슘 점수를 가진 환자에서 관상동맥 CT 조영술을 이용한 협착 평가의 한계와 전망 (Assessment of Coronary Stenosis Using Coronary CT Angiography in Patients with High Calcium Scores: Current Limitations and Future Perspectives)

  • 강두경
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.270-296
    • /
    • 2024
  • 관상동맥 CT 조영술은 높은 정확도로 유의한 관상동맥 협착을 발견할 수 있어 관상동맥 질환이 의심되는 환자들에서 침습적 관상동맥 조영술의 문지기로서의 역할을 인정받고 있다. 그러나 관상동맥에 과도한 석회화 경화반이 있으면 내강을 시각화하기 어려워 영상의 해석에 오류를 초래할 수 있다. 이는 주로 CT 스캐너의 제한적인 공간 해상도로 인해 석회화 경화반에 의한 번짐허상이 발생하기 때문이다. 그럼에도 불구하고, 높은 칼슘 점수를 보이는 CT 영상에서 관상동맥 협착을 평가해야 하는 상황을 종종 마주한다. 이러한 한계를 극복하기 위한 기술적인 방법으로 고해상도 CT 스캐너의 도입, 새로운 재구성 기법 및 후처리 기술의 개발, 감산기법 등이 있으며, 판독에 도움이 되는 방법으로 적절한 창너비 및 창높이의 설정, 혈관의 단면 영상에서 석회화 경화반의 범위 및 내강의 잔류 가시성 평가 등이 권고된다.

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단 (Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9)

  • 장대환;최덕주;이범우;박원;한창순;김학산;김종순
    • 대한핵의학회지
    • /
    • 제22권1호
    • /
    • pp.83-92
    • /
    • 1988
  • The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  • PDF

IMACIS-1을 이용한 위장관 종양의 방사면역신티그램 (Radioimmunoscintigraphy Using IMACIS-1 in Gastrointestinal Cancer)

  • 손형선;김춘열;박용휘
    • 대한핵의학회지
    • /
    • 제24권1호
    • /
    • pp.29-36
    • /
    • 1990
  • Most of the diagnostic methods currently used for the detection of neoplastic masses provide indirect evidence. To obtain greater specificity in the interpretation of neoplasias by in vivo methods, the immunological approach appears to be most promising. Two problems that interfered with progress in this field were the lack of tumor specific antigen and the lack of well-defined and reproducible antibodies. To improve the sensitivity and specificity of radioimmunoscintigraphy as a technique for tumor localization, the use of monoclonal antibodies, fragments of antibodies and single photon emission computerized tomography (SPECT) are reasonable. The obvious advantages of monoclonal antibodies are their homogeneity, their specificity for the immunizing antigen and the reaction with a single determinant-thus no large immunecomplexes with antigen are formed. Monoclonal antibody technique has recently provided an opportunity to reevaluate the role of nuclear medicine for the diagnosis of malignant diseases by using the immunological approach. Out first results by means of radioimmunoscintigraphy of CEA and CA 19-9 producing tumors using a cocktail of fragments F $(ab')_2$, of mocolonal antibodies to CA 19-9 and CEA labeled with $^{131}I$ (IMACIS-1) are reported. The aims of this investigation was to evaluate the role of immunoscintigraphy in patients with colorectal and other cancers for diagnosis of local recurrences and metastasis. This report contains results of the first 8 colorectal and pancreas cancer patients with the elevation of the level of serum CEA and/or CA 19-9. IMACIS-1 was injected intravenously during 30 minutes in 100 ml saline solution after skin test. Planar scintigrams were recorded 3, 5 and 7 days after the injection of the IMACIS-1. Anterior, lateral and posterior views of the liver as well as anterior and posterior views of the pelvis were obtained in each patients as an $^{131}I-antibody$ image. We were able to localize exactly the malignant process with the double-nuclide double-compound $^{99m}Tc\;^{131}I$ (Tc+l) scintigrams. In Tc & I double-nuclide scintigraphy, computer subtraction display provided more clear localization of the tumor. We compared the results of radioimmunoscintigraphy with CT, ultrasonograms, conventional scintigrams. The results were as follows: 1) The sensitivity and specificity of radioimmunoscintigraphy using the fragments $F(ab')_2$ of the cocktails of CEA and CA 19-9 monoclonal antibodies were 80% and 100% respectively. 2) Tumor detection rate was not proportionated to the level of serum tumor markets. 3) Second tracer technique was essential for tumor localization as an anatomic landmark using double-nuclide scintigraphy. 4) A slow infusion of the antibodies was necessary to prevent the formation of large immune complexes. 5) Tumor/non-tumor radioactivity was most elevated at 7 days delayed imaging. 6) Using planar scintigraphic technique of $^{131}I$ labeled monoclonal antibodies are possible for imaging most of the tumors.

  • PDF