Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

Effect of Matrigel for Bone Graft using Hydroxyapatite/Poly $\varepsilon$-caprolactone Scaffold in a Rat Calvarial Defect Model (랫드의 두개골결손부 모델에서 HA/PCL 지지체를 사용한 골이식 시 Matrigel의 효과)

  • Kim, Se-Eun; Shim, Kyung-Mi;Kim, Seung-Eon;Choi, Seok-Hwa;Bae, Chun-Sik;Han, Ho-Jae;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.325-329
    • /
    • 2010
  • The osteogenic potential of hydroxyapatite/poly $\varepsilon$-caprolactone composite (HA/PCL) scaffolds with matrigel was evaluated in a rat calvarial defect model. Calvarial defect formation was surgically created in Sprague Dawley rats (n = 18). HA/PCL scaffold was grafted with matrigel (M-HA/PCL group, n = 6) or without matrigel (HA/PCL group, n = 6). A critical defect group (CD group, n = 6) did not received a graft. Four weeks after surgery, bone formation was evaluated with radiography, micro computed tomography (micro CT) scanning, and histologically. No bone tissue formation was radiographically evident in the CD group. Bone tissue was radiographically evident in the HA/PCL and M-HA/PCL groups, however, there was more bone-similar opacity in the M-HA/PCL group. Micro CT analysis revealed that the bone volume of the M-HA/PCL group was higher than the HA/PCL group, however, no significant difference was found between the HA/PCL and M-HA/PCL groups. Bone mineral density in the M-HA/ PCL group was significantly higher than in the HA/PCL group (p < 0.05). Histologically, new bone was formed only from existing bone in the CD group, showing concavity without bone formation in the defect. In the HA/PCL group, new bone formation was only derived from existing bone, while in the M-HA/PCL group the largest bone formation was observed, with new bone tissue forming at the periphery of existing bone and around the HA/PCL scaffold with matrigel. The results indicate that the combination of HA/PCL scaffold with matrigel may be an effective means of enhancing bone formation in critical-sized bone defects.

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Analysis of the Manufacturing Techniques for the KwangDahoe Tying on the Sword in Joseon Dynasty (조선시대 도검 패용 광다회의 제작기법 분석)

  • Baek, Je-Sun;Chung, Kwang-Young
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.3
    • /
    • pp.64-87
    • /
    • 2017
  • Dahoe is a traditional braid in Joseon Dynasty. There are many Dahoe artifacts, which can give us a glimpse of the costume, culture, and life of that era. The study of Dahoe is necessary in various fields, but it is difficult because this manufacturing technique has been passed down from hand to hand. Few studies have been done so far. This research examines the manufacturing technique of KwangDahoe which is passed down by Maedeupjang (Decorative Knotting) and is generally used for knotting and/or tying objects. The main characteristic of TieKwangDahoe, made through the same method as WonDahoe, is the square hole in the middle. It was impossibile to remake the original braid because there is no confirmed number of the strand. Especially it is very difficult to do conservation and restoration on serious degradation state of the fiber. Therefore, it is necessary to analyze the non-destructive manufacturing techniques method for Dahoe and assess their applicability. First, we analyzed the artifacts' manufacturing technique based on the database of the Dahoe's manufacturing technique. In order to do that, we undertook schematization, restoration, morphological analyzation of the Dahoe. And then, X-ray CT scans were performed to improve the reliability of the DB. These results of scanning were interpreted based on the manufacturing technique. The selected Tie-KwangDahoe on the sword for the study are artifacts including artistic value and symbolism in Joseon Dynasty. Based on the analysis of the manufacturing technique, we found that both artifacts were made of 20-strand braid of single cross according to the length-scale measure. It was manufactured using 8-strand on left-right side, 12-strand on front-back side by the braiding manufacturing technique method Finally, this research suggests non-destructive analysis method of Dahoe's manufacturing technique is based on the database and the analysis results. I hope this research can be useful in various professional fields of Dahoe in the future. Moreover, I hope this can be of any help in preserving Korean cultural heritage.

Comparison Study on Projection and Backprojection Methods for CT Simulation (투사 및 역투사 방법에 따른 컴퓨터단층촬영 영상 비교)

  • Oh, Ohsung;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.323-330
    • /
    • 2014
  • Image reconstruction is one of the most important processes in CT (Computed tomography) technology. For fast scanning and low dose to the objects, iterative reconstruction is becoming more and more important. In the implementation of iterative reconstruction, projection and backprojection processes are considered to be indispensable parts. However, many approaches for projection and backprojection may result severe image artifacts due to their discrete characteristics and affects the reconstructed image quality. Thus, new approaches for projection and backprojection are highly demanded these days. In this paper, distance-driven approach was evaluated and compared with other conventional methods. The numerical simulator was developed to make the phantoms, and projection and backprojection images were compared using these approaches. As a result, it turned out that there are less artifacts during projection and backprojection in parallel and fan beam geometry.

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.

Comparison of Hounsfield Units by Changing in Size of Physical Area and Setting Size o f Region o f Interest b y Using the CT Phantom Made with a 3D Printer (3D 프린터로 제작된 CT 팬톰을 이용한 물리적 관심영역과 설정 관심영역의 크기에 따른 하운스필드의 비교)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In this study, we have observed the change of the Hounsfield (HU) in the alteration of by changing in size of physical area and setting size of region of interest (ROI) at focus on kVp and mAs. Four-channel multi-detector computed tomography was used to get transverse axial scanning images and HU. Three dimensional printer which is type of fused deposition modeling (FDM) was used to produce the Phantom. The structure of the phantom was designed to be a type of cylinder that contains 33 mm, 24 mm, 19 mm, 16 mm, 9 mm size of circle holes that are symmetrically located. It was charged with mixing iodine contrast agent and distilled water in the holes. The images were gained with changing by 90 kVp, 120 kVp, 140 kVp and 50 mAs, 100 mAs, 150 mAs, respectively. The 'image J' was used to get the HU measurement of gained images of ROI. As a result, it was confirmed that kVp affects to HU more than mAs. And it is suggested that the smaller size of physical area, the more decreasing HU even in material of a uniform density and the smaller setting size of ROI, the more increasing HU. Therefore, it is reason that to set maximum ROI within 5 HU is the best way to minimize in the alteration of by changing in size of physical area and setting size of region of interest.

The validation of Periotest values for the evaluation of orthodontic mini-implants' stability (즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest$^{(R)}$의 유효성)

  • Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.167-175
    • /
    • 2010
  • Objective: The aim of this study was to validate the Periotest values for the prediction of orthodontic mini-implants' stability. Methods: Sixty orthodontic mini-implants (7.0 mm $\times$ $\emptyset1.45$ mm; ACR, Biomaterials Korea, Seoul, Korea) were inserted into the buccal alveolar bone of 5 twelve month-old beagle dogs. Insertion torque (IT) and Periotest values (PTV) were measured at the installation procedure, and removal torque (RT) and PTV were recorded after 12 weeks of orthodontic loading. To correlate PTV with variables, the cortical bone thickness (mm) and bone mineral density (BMD) within the cortical bone and total bone area were calculated with the help of CT scanning. Results: The BMD and cortical bone thickness in mandibular alveolus were significantly higher than those of the maxilla (p < 0.05). The PTV values ranged from -3.2 to 4.8 for 12 weeks of loading showing clinically stable mini-implants. PTV at insertion was significantly correlated with IT (-0.51), bone density (-0.48), cortical bone thickness (-0.42) (p < 0.05) in the mandible, but showed no correlation in the maxilla. PTV before removal was significantly correlated with RT (-0.66) (p < 0.01) in the mandible. Conclusions: These results show that the periotest is a useful method for the evaluation of mini-implant stability, but it can only be applied to limited areas with thick cortical and high density bone such as the mandible.

Reliability Assessment and Prediction of Solder Joints in High Temperature Heaters (고온히터 솔더접합부의 신뢰성 평가 및 예측)

  • Park, Eunju;Kwon, Daeil;Sa, Yoonki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.23-27
    • /
    • 2017
  • This paper proposes an approach to predict the reliability of high temperature heaters by identifying their primary failure modes and mechanisms in the field. Test specimens were designed to have the equivalent stress conditions with the high temperature heaters in the field in order to examine the effect of stress conditions on the solder joint failures. There failures often result from cracking due to intermetallic compound (IMC) or void formation within a solder joint. Aging tests have been performed by exposing the test specimens to a temperature of $170^{\circ}C$ in order to reproduce solder joint failures in the field. During the test, changes in IMC formation were investigated by scanning electron microscopy (SEM) on the cross-sections of the test specimens, while changes in void formation were monitored both by resistance spectroscopy and by micro-computed tomography (microCT), alternately. The test results demonstrated the void volume within the solder increased as the time at the high temperature increased. Also, the phase shift of high frequency resistance was found to have high correlation with the void volume. These results implied the failure of high temperature heaters can be non-destructively predicted based on the correlation.