• Title/Summary/Keyword: CT contrast media

Search Result 84, Processing Time 0.023 seconds

THE DIAGNOSIS OF IMPACTED MAXILLARY MESIODENS USING 3-DIMENSIONAL COMPUTED TOMOGRAPHY : A CASE REPORT (3차원 전산화 단층촬영을 이용한 상악 정중 과잉치의 진단)

  • Hong, Young-Woo;Kim, Seong-Oh;Sohn, Hyung-Kyu;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.549-554
    • /
    • 1998
  • The prevalence of the supernumerary tooth is $1{\sim}4%$. It usually occurs in the permanent dentition. It frequently occurs in the maxillary mid palatal area. The presence of the supernumerary tooth causes the following problems ; (1) interfering the eruption of successional tooth, (2) displacing the neighboring teeth, (3) resulting large diastema, (4) forming cystic change. So the supernumerary tooth should be removed as soon as possible. To extract the supernumerary tooth, the exact position must be noticed first. Radiographic techniques that were used in the past are tube shift technique, right angle technique, sterioradiography, using radiopaque contrast media and conventional tomography. But these methods include the subjective opinion of the operator. So, a technique eliminating the operator's opinion and showing the position 3-dimentionally can be used. 3-dimentional computed tomography equipped with dental softwares can show the position of the impacted supernumerally tooth in 3-dimentional position. It has an advantage to eliminate the subjective opinion of the operator. With a fast computer this techenique is done in a relatively short period of time. The rationale of this methods is relatively simple. After tacking X-ray and reconstructing the data 3-dimentionally, sequential removal of the soft tissue and hard tissue(bone) CT number leaves the teeth alone in 3-dimentional position. The image can be seen from anywhere, so the operator can see the image in front, rear, upper, and lower positions. In both cases 1 and 2, the position of the impacted supernumerary tooth is viewed by the 3-dimensional computed tomography. And it made the operator easy to figureout the exact position.

  • PDF

Current Status of MRI Distribution, Prevailing Charges and Analysis of Its Performance (MRI 분포와 관행수가 현황 및 촬영실적 분석)

  • 문옥륜;장원기;이상이;김철웅;최경혜
    • Health Policy and Management
    • /
    • v.8 no.1
    • /
    • pp.155-182
    • /
    • 1998
  • There exists a remarkable differences in use of MRI scanning among income classes. The poor can hardly utilize it. This is because, among high cost technnologies, MRI is the only equipment not covered under health insurance benefits in Korea. This study was designed 1) to reveal the status of nation-wide MRI installation, customary charges and per unit annual scanning performance, and 2) to analyse factors influencing the above variables. The data for this study came from "MRI Prevalence Survey" conducted by the National Federation of Medcial Insurance(NFMI) in 1997, and were analyzed through SAS packages for T-test, analysis of variance and stepwise multiple regression. Data were collected from 188 hospitals equipped with MRI scanners. Major findings are summarized as follows : The number of MRI scanners has increased from 69 in 994 to 158 in 1996(2.3 times) while per unit annual scanning performance has risen by 11.2% from 2,173 cases in 1994 to 2,417 cases in 1996. Such a rapid increase was made possible mainly due to the inclusion of CT scanning under the health insurance benefit package. The customary charges for MRI scanning with or without contrast media, on average, amounted to 484,000 Won and 402,000 Won, respectively, with the percentile increase of 17.8% and 8.1% each during the same time. Korea ranks the third worldwidely in terms of number of MRI installations, 4.8 scanners per one million persons, only next to Japan and United States. Geographical variation of MRI, however, was rather high, 7.91 unit, in Cheju area compared to 1.82 in Kyongnam area. Variations of customary charges of MRI scanning can be explained as much as by 44.8% by both the total amount of claims to NFMI and geographical variable. The charges were more likely to be higher in metropolitan areas like Seoul and in hospitals with a bigger amount of claims. While those of per unit annual scanning performance can be explained as much as by 30.7% by both MRI installation cost and level of MRI-installed organizations. Per capital scannig performance was higher in tertiary hospitals and hospitals equipped with more expensive scanners than hospitals with less expensive scanners. Two measures are called for the remedying the existing excessive abundance in MRI units in korea : One is to set a ceiling of MRI units in an area like a province or a metropolitan district. The other is to establish a committee on introduction of high cost technologies for reviewing its effective use.ctive use.

  • PDF

Ultrasmall Polyethyleneimine-Gold Nanoparticles with High Stability (높은 안정성을 갖는 초미립 폴리에틸렌이민-금 나노입자)

  • Kim, Eun-Jung;Yeum, Jeong-Hyun;Ghim, Han-Do;Lee, Se-Guen;Lee, Ga-Hyun;Lee, Hyun-Ju;Han, Sang-Ik;Choi, Jin-Hyun
    • Polymer(Korea)
    • /
    • v.35 no.2
    • /
    • pp.161-165
    • /
    • 2011
  • This study is related to the preparation of biocompatible gold nanoparticles (AuNPs) which are stable in aqueous solutions for a long time. Ultrasmall polyethyleneimine (PEI)-capped AuNPs (PEI-AuNPs) with limited agglomeration were prepared in aqueous solutions at room temperature, which were based on the roles of PEI as a reductant and a stabilizer. PEI-AuNPs with an average size of 8~12 nm formed highly stable nanocolloids with an average hydrodynamic cluster size of around 50 nm in aqueous media. At a low concentration of metal precursor hydrogen tetrachloroaurate (III), the particle size was reduced noticeably. The typical peaks of gold were observed in the X-ray diffraction pattern of AuNPs. The cell viability of 98% was obtained in the case of PEI-AuNPs, while PEI was cytotoxic. The PEI-AuNP is considered to be a potential candidate as a contrast agent for computed tomography.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.