• Title/Summary/Keyword: CT contrast media

Search Result 81, Processing Time 0.032 seconds

External Auditory Canal Atresia with Otitis Media in a Dog

  • Kim, Ah Reum;Han, Changhee;Hwang, Gunha;Kim, Rakhoon;Go, Woohyun;Lee, Ji Yeong;Lee, Jongbong;An, Soyon;Hwang, Tae Sung;Lee, Dongbin;Lee, Jae-Hoon;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.159-162
    • /
    • 2021
  • A 5-year-old, intact male, poodle dog with right external auditory canal obstruction and subaural mass was presented. Physical examination revealed that right external auditory canal opening was absent and right head tilt was identified. Aspiration in right subaural mass revealed a small amount of dark brown exudate. Streptococcus canis and Staphylococcus spp. were identified on the microbial culture. Radiography of the skull was revealed absence of air-filled ear canal at the right external ear canal (EEC) level. Computed tomography (CT) revealed well capsulated, hypoattenuated mass in the right EEC region. On the contrast enhanced CT images, rim enhancement around the mass and ear canal obstruction were identified. Fluid attenuated material filled with right bulla. Mild thickening of the right tympanic bulla wall with mild lytic lesion of the ventral wall were found. Based on the images findings, the case was tentatively diagnosed as right external auditory canal atresia with otitis media. Total ear canal ablation and lateral bulla osteotomy was performed. The entire ear canal was removed, numerous hair in the canal and the thickening wall were founded. Right ear canal was sent for histopathological evaluation and found to otitis externa. The patient was followed up for two weeks and there were no complications. This report described the CT diagnosis of right EEC atresia with otitis media rarely reported in small breed dogs.

Effect on Alzheimer's Disease by Sesim-tang in CT105-overexpressed SK-N-SH Cell Lines (CT105로 유도된 신경모세포종 세포주에서 세심탕의 항치매 효과)

  • 권형수;박치상;박창국
    • The Journal of Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.138-150
    • /
    • 2004
  • Objectives : Alzheimer's disease (AD) is a geriatric dementia that is widespread in old age. In the near future AD will be the biggest problem in public health service. Although a variety of oriental prescriptions, including Sesim-tang, have been traditionally utilized for the treatment of AD, their pharmacological effects and action mechanisms have not yet been fully elucidated. The present study investigated the effects of Sesim-tang on apoptotic cell death induced by CT105 (carboxy terminal 105 amino acid peptide fragment of APP) overexpression in SK-N-SH neuroblastoma cell lines. Methods: We studied the regenerative and inhibitory effects on Alzheimer's disease in CT105-induced SK-N-SH cell lines by Sesim-tang water extract. We examined for cell morphological pattern, DNA fragmentation, LDH activity assay, zymography assay, and immunohistochemistric analysis. Additionally, we investigated the association between the CT105 and neurite degeneration caused by CT105-induced apoptotic response in neurone cells. Results: Findings from our experiments have shown that Sesim-tang inhibits the synthesis or activities of CT105, which has neurotoxicities and apoptotic activities in the cell line. In addition, pretreatment with Sesim-tang ($>50\mu\textrm{g}/ml$ for 12 hours) partially prevented CT105-induced cytotoxicity in SK-N-SH cell lines. SK-N-SH cell lines overexpressed with CT105 exhibited remarkable apoptotic cell damage. Based on morphological observations by phase-contrast microscope and LDH activity measurements in the culture media, the CT105-induced cell death was significantly inhibited by Sesim-tang water extract. Sesim-tang was found to reduce the expression of APP and caspase-3 induced by CT105 in SK-N-SH cell lines and in rat hippocampus. Conclusions: As the result of this study, in the Sesim-tang group, apoptosis in the nervous system is inhibited, the repair against the degeneration of SK-N-SH cell lines by CT105 expression is promoted. Hence, Sesim-tang may be beneficial for the treatment of AD.

  • PDF

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Renal Safety of Repeated Intravascular Administrations of Iodinated or Gadolinium-Based Contrast Media within a Short Interval

  • Chiheon Kwon;Koung Mi Kang;Young Hun Choi;Roh-Eul Yoo;Chul-Ho Sohn;Seung Seok Han;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1547-1554
    • /
    • 2021
  • Objective: We aimed to investigate whether repeated intravascular administration of iodinated contrast media (ICM) or gadolinium-based contrast agents (GBCAs) within a short interval was associated with an increased risk of post-contrast acute kidney injury (PC-AKI). Materials and Methods: This retrospective study included 300 patients (mean age ± standard deviation, 68.5 ± 8.1 years; 131 male and 169 female) who had undergone at least one ICM-enhanced perfusion brain CT scan, had their baseline and follow-up serum creatinine levels available, and had not undergone additional contrast-enhanced examinations 72 hours before and after a time window of interest were included. The study population was divided into three groups: single-dose group and groups of patients who had received multiple contrast administrations in the time window of interest with the minimum contrast repeat interval either within 4 hours (0-4-hour group) or between 4 to 48 hours (4-48-hour group). Multivariable logistic regression analysis was conducted to evaluate the association between AKI and repeated ICM administrations. A similar supplementary analysis was performed including both ICM and GBCA. Results: When ICM was only considered ignoring GBCA, among 300 patients, 207 patients received a single dose of ICM, 58 had repeated doses within 4 hours (0-4-hour group), and 35 patients had repeated doses between 4 to 48 hours (4-48-hour group). Most patients (> 95%) had a baseline estimated glomerular filtration rate (eGFR) of ≥ 30 mL/min/1.73 m2. AKI occurred in 7.2%, 13.8%, and 8.6% of patients in the single-dose, 0-4-hour, and 4-48-hour groups, respectively. In the 0-4-hour and 4-48-hour groups, additional exposure to ICM was not associated with AKI after adjusting for comorbidities and nephrotoxic drugs (all p values > 0.05). Conclusion: Repeated intravascular administrations of ICM within a short interval did not increase the risk of AKI in our study patients suspected of acute stroke with a baseline eGFR of ≥ 30 mL/min/1.73 m2.

Acute Spontaneous Subdural Hematoma of Arterial Origin

  • Sung, Soon-Ki;Kim, Sung-Hoon;Son, Dong-Wuk;Lee, Sang-Weon
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.2
    • /
    • pp.91-93
    • /
    • 2012
  • Acute spontaneous subdural hematoma (SDH) of arterial origin is very rare. We report a case of acute spontaneous SDH that showed contrast media extravasation from cortical artery on angiograms. A 58-year-old male patient developed sudden onset headache and right hemiparesis. Brain CT scan demonstrated acute SDH at left convexity. The patient was drowsy mentality on admission. He had no history of head trauma. Cerebral angiography was performed and revealed a localized extravasation of the contrast media from distal cortical MCA branch. After angiography, the patient deteriorated to comatose mentality. Decompressive craniectomy for removal of SDH was performed. We verified the arterial origin of the bleeding and coagulated the bleeding focus. The histological diagnosis was aneurysmal artery. He recovered after surgery with mild disability. In a case of acute spontaneous SDH, the possibility of a cortical artery origin should be considered.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.