• Title/Summary/Keyword: CT angiography

Search Result 282, Processing Time 0.029 seconds

Traumatic Pseudoaneurysm of the Superficial Temporal Artery diagnosed with 3-Dimensional Computed Tomography Angiography: Two Cases Report (3차원 컴퓨터단층촬영 혈관조영술을 이용하여 진단한 외상성 천측두동맥 가성동맥류의 치험례)

  • Kwon, Ho;Hwang, Dong Yeon;Jung, Sung-No;Yim, Young Min;Shin, Ok Ran
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.265-268
    • /
    • 2007
  • Purpose: Superficial temporal artery(STA) aneurysms are very rare and mostly occur as pseudoaneurysms secondary to trauma. Clinical diagnosis of STA pseudoaneurysm is based on a history of trauma or surgery to frontotemporal region, which presents with pulsatile mass. To confirm diagnosis, many imaging strategies can be used such as digital subtraction angiography, sonography, CT and MRI. But, these imaging modalities are invasive or inaccurate or expensive. Thus, we used 3D CT angiography to confirm STA aneurysm and to get accurate information. Methods: We have experienced two cases of pulsatile mass on the temporal area, suspected as STA pseudoaneurysms. On the basis of clinical information, we performed 3D CT angiography to get more accurate information about this pulsatile mass and to confirm diagnosis. On the basis of information from 3D CT angiography, we performed operation. Results: The lesions were diagnosed as pseudoaneurysm of superficial temporal artery by 3D CT angiography, and surgically resected safely without any complication on the basis of information from 3D CT angiography. 3D CT angiography was excellent diagnostic method for detecting STA pseudoaneurysms, and effectively showed many information about pseudoanerysms such as relationship between the aneurysms and surrounding structures, and its size. Conclusion: We could effectively diagnose and treat on the basis of information from 3D CT angiography. We present our cases with a brief review of the literature related to STA traumatic pseudoaneurysms.

Usefullness with 3D CT Angiography in Microsurgical Reconstruction (미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성)

  • Sung, Yong Duck;Kim, Hyo Heon
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

Preoperative Identification of Perforator Using CT Angiography in Fibular Osteocutaneous Free Flap Head and Neck Reconstruction (유리비골피부피판을 이용한 두경부 재건 시 CT Angiography를 통한 천공지의 확인)

  • Chang, Tack-Jin;Kim, Eun Key;Choi, Jong Woo
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2012
  • Purpose: Fibular osteocutaneous free flap is the procedure of choice for mandibular reconstruction. However, the anatomic consistency and the reliability of the skin paddle have been considered to be questionable and the utilization of the fibular osteocutaneous free flap can be challenging for the inexperienced surgeon. Preoperative computed tomography (CT) angiography can support revolutionary help with the operator design of the fibular osteocutaneous flap. The purpose of this article is to share the valuable experience of support with preoperative CT angiography. Methods: Three consecutive patients, who needed mandibular reconstruction, were treated with fibular osteocutaneous free flap. Each of the patients had undergone lower extremity CT angiography before the surgery. The CT angiographies were scrupulously investigated to calculate the locations and the tracts of the peroneal artery perforators. We compared the findings of the CT angiography with those of the real operation. Results: The information about the perforators was sufficiently matched with the findings of the operation. With the use of preoperative CT angiography, we were able to achieve confident performance during operation, shortening of operation time, and fine outcomes with a no flap failure. Conclusion: The CT angiography of lower extremity can provide reliable information of the perforators of the fibular osteocutaneous free flap.

The Evaluation of Carotid Artery Stenosis Using Spiral CT. (Spiral CT를 이용한 경동맥 질환의 평가)

  • Yoon, Hee-Suk;Hwang, Yun-Chean;Shin, Hyun-Kil;Beak, Cheon-Ki;Yoon, Suck-Min
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

Comparison of Doppler and CT Angiography as a Predictor of Healing Diabetic Foot Ulcers (당뇨발 치유 가능성의 예측을 위한 도플러와 CT 혈관조영술의 비교)

  • Park, Doug-John;Kim, Hyon-Surk;Han, Seung-Kyu;Kim, Hee-Young;Chun, Kyung-Wook;Kim, Woo Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.495-500
    • /
    • 2008
  • Purpose: Adequate tissue oxygenation is considered as an essential factor for wound healing. In the non-diabetic population, an uncompromised macrocirculation generally leads to adequate tissue oxygenation. On the contrary, the macrocirculation in diabetic patients may not correlate with tissue oxygenation because of structural changes in the capillary basement membrane. Nevertheless, many medical professionals in Korea rely on macrocirculation evaluation when predicting wound healing potential of the diabetic ulcers. The purpose of this study is to compare reliability of two common macrocirculation assessment methods, Doppler probing and CT angiography, on tissue oxygenation in diabetic foot patients. Methods: Doppler and CT angiography scores were given according to the patency of the anterior and posterior tibial arteries. Tissue oxygenation was measured by transcutaneous partial oxygen tension($TcpO_2$). Doppler and CT angiography scores were statistically analyzed against $TcpO_2$ values. Sixty-eight diabetic foot ulcer patients were included in this study. Results: The test was carried out on Doppler score and $TcpO_2$ variables displayed a p-value of 0.0202, and concluded that the two variables were statistically dependent. The test used to determine for linear trends between Doppler scores and $TcpO_2$ variables displayed a p-value of 0.0149, displaying statistical linear trend between the two variables. On the contrary, the tests between CT angiography scores and $TcpO_2$ variables showed p-values of 0.1242 and 0.6590, that means no correlation between CT angiography and $TcpO_2$ scores. Conclusion: Doppler probing is more reliable than CT angiography in predicting tissue oxygenation of diabetic foot ulcers.

Accuracy in target localization in stereotactic radiosurgery using diagnostic machines (정위적 방사선수술시 진단장비를 이용한 종양위치결정의 정확도 평가)

  • 최동락
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.3-7
    • /
    • 1996
  • The accuracy in target localization of CT, MR, and digital angiography were investigated for stereotactic radiosurgery. The images using CT and MR were obtained out of geometrical phantom which was designed to produce exact coordinates of several points within a 0.lmm error range. The slice interval was 3mm and FOV was 35cm for CT and 28cm for MR. These images were transferred to treatment planning computer using TCP/IP in forms of GE format. Measured 3-D coordinates of these images from planning computer were compared to known values by geometrical phantom. Anterior-posterior and lateral films were taken by digital angiography for measurement of spatial accuracy. Target localization errors were 1.2${\pm}$0.5mm with CT images, 1.7${\pm}$0.4mm with MR-coronal images, and 2.1${\pm}$0.7mm with MR-sagittal images. But, in case of MR-axial images, the target localization error was 4.7${\pm}$0.9mm. Finally, the target localization error of digital angiography was 0.9${\pm}$0.4mm. The accuracy of diagnostic machines such as CT, MR, and angiography depended on their resolutions and distortions. The target localization error mainly depended on the resolution due to slice interval with CT and the image distortion as well as the resolution with MR However, in case of digital angiography, the target localization error was closely related to the distortion of fiducial markers. The results of our study should be considered when PTV (Planning Target Volume) was determined.

  • PDF

Atypical Patterns of Deep Inferior Epigastric Artery: Clinical Implication of Preoperative CT Angiography (비전형적인 심하복벽동맥의 주행을 파악하기 위한 수술 전 CT Angiography의 유용성)

  • Lee, Taek-Jong;Kim, Sung-Chan;Eom, Jin-Sup;Kim, Eun-Key
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Purpose: Purpose: The free deep inferior epigastric artery perforator (DIEP) flap is a popular option for autologous breast reconstruction. However, the anatomy of the deep inferior epigastric artery(DIEA) may vary from one individual to another. Unexpected vascular anomaly can confuse the surgeon and affects on the safety of the free DIEP flap. Materials and Methods: Thirty five consecutive patients who underwent free DIEP/TRAM flap for immediate breast reconstruction between Mar. 2010 and Oct. 2010 were enrolled in this study. Computed tomography angiography (CT angiography) of abdomen was evaluated part of our standard preoperative assessment: atypical patterns of DIEA/DIEP were evaluated by preoperative CT angiography and compared with intraoperative finding. Results: Atypical patterns of DIEA/DIEP which may affect preoperative planning were noted as the following: Circummusclar/subfascial DIEA (n=1), DIEA running underneath rectus muscle (n=8), septocutaneous perforator (n=3), peritoneo-cutaneous perforator (n=1), a large branch going into peritoneum (n=1), and very early division and muscle penetration of DIEA (n=1). Conclusion: Atypical DIEA/DIEP that might change the operation plan is not rare, so the individualized planning based on the preoperative CT angiography is recommended. Preoperative CT angiography could help to select reliable and easy-to-dissect perforator in free DIEP/TRAM breast reconstruction.

  • PDF

Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study

  • Choo, Ki-Seok;Lee, Tae-Hong;Choi, Chang-Hwa;Park, Kyung-Pil;Kim, Chang-Won;Kim, Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.284-288
    • /
    • 2009
  • Objective : Our retrospective study aimed to determine whether 16-slice computerized tomography (CT) angiography optimized sharp kernel is suitable for the evaluation of visibility, luminal patency and re-stenosis of intracranial stents in comparison with conventional angiography. Methods : Fifteen patients with symptomatic intracranial stenotic lesions underwent balloon expandable stent deployment of these lesions (10 middle cerebral arteries, 2 intracranial vertebral arteries, and 3 intracranial internal carotid arteries). CT angiography follow-up ranged from 6 to 15 months (mean follow-up, 8 months) after implantation of intracranial stents and conventional angiography was confirmed within 2 days. Curved multiplanar reformations with maximal intensity projection (MIP) with optimal window settings for assessment of lumen of intracranial stents were evaluated for visible lumen diameter, stent patency (contrast distal to the stent as an indirect sign), and re-stenosis by two experienced radiologists who blinded to the reports from the conventional angiography. Results : All of stents deployed into symptomatic stenotic lesions. All stents were classified as patent and no re-stenosis, which was correlated with results of conventional angiography. Parts of the stent lumen could be visualized in all cases. On average, 57% of the stent lumen diameter was visible using optimized sharp kernel. Significant improvement of lumen visualization (22%, p<0.01) was observed using the optimized sharp kernel compared with the standard sharp kernel. Inter-observer agreements on the measurement of lumen diameter and density were judged as good, respectively (p<0.05). Conclusion : Sixteen-slice CT using the optimized sharp kernel may provide a useful information for evaluation of lumen diameter patency, and re-stenosis of intracranial stents.

A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs (비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험)

  • Jeong Yu-Cheol;Lim Chang-Yun;Kim Gyeong-Min;Lee Sung-Ok;Jung Joo-Hyun;Chang Jin-Hwa;Oh Sun-Kyoung;Song Kyoung-Jin;Yoon Jung-Hee;Choi Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

Determination of Early Graft Patency Using CT Angiography after Coronary Artery Bypass Surgery (관상동맥우회술 후 CT 조영술을 이용한 이식편의 조기 열림의 판정)

  • 이미경;류대웅;최순호;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.570-577
    • /
    • 2004
  • CT angiography is now available to evaluate the early graft patency after coronary bypass surgery. We investigated whether patency or occlusion of the bypass grafts can be visualized by CT angiography and what factors effect the visuality. Material and Method: Fifty patients underwent scanning with a 4-slice computed tomographic scanner (Somatom Volume ZoomTM; Siemens, Germany) before being discharged after coronary artery bypass grafting. To evaluate graft patency and relationship between the quality of graft image and the characteristics of the diseased coronary vessels, 50 internal thoracic artery grafts, 18 radial artery grafts, and 56 vein grafts were included in this study. Result: All vein grafts (24 grafts; 32 anastomoses) to left coronary artery system were well visualized, but 3 grafts (4.7%) of 30 vein grafts (35 anastomoses) to right coronary artery system were not visualized. The latter was also occluded in invasive coronary angiographic study. Thirty-nine (78%) internal thoracic artery grafts were well visualized, 8 (16%) faintly visualized, and 3 (6%) not visualized, but all the internal artery grafts were well patent in invasive coronary angiographic study. Conclusion: Unvisualized vein grafts in CT angiography means occlusion of the grafts, but unvisualized arterial grafts in CT angiography may not mean occlusion of the graft but result from competitive flow between the graft and coronary artery. To confirm patency of the unvisualized arterial grafts, invasive coronary angiography is needed.