Browse > Article
http://dx.doi.org/10.3340/jkns.2009.45.5.284

Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study  

Choo, Ki-Seok (Departments of Diagnostic Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine)
Lee, Tae-Hong (Departments of Diagnostic Radiology, Pusan National University Hospital, Pusan National University School of Medicine)
Choi, Chang-Hwa (Departments of Neurosurgery, Pusan National University Hospital, Pusan National University School of Medicine)
Park, Kyung-Pil (Departments of Neurology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine)
Kim, Chang-Won (Departments of Diagnostic Radiology, Pusan National University Hospital, Pusan National University School of Medicine)
Kim, Suk (Departments of Diagnostic Radiology, Pusan National University Hospital, Pusan National University School of Medicine)
Publication Information
Journal of Korean Neurosurgical Society / v.45, no.5, 2009 , pp. 284-288 More about this Journal
Abstract
Objective : Our retrospective study aimed to determine whether 16-slice computerized tomography (CT) angiography optimized sharp kernel is suitable for the evaluation of visibility, luminal patency and re-stenosis of intracranial stents in comparison with conventional angiography. Methods : Fifteen patients with symptomatic intracranial stenotic lesions underwent balloon expandable stent deployment of these lesions (10 middle cerebral arteries, 2 intracranial vertebral arteries, and 3 intracranial internal carotid arteries). CT angiography follow-up ranged from 6 to 15 months (mean follow-up, 8 months) after implantation of intracranial stents and conventional angiography was confirmed within 2 days. Curved multiplanar reformations with maximal intensity projection (MIP) with optimal window settings for assessment of lumen of intracranial stents were evaluated for visible lumen diameter, stent patency (contrast distal to the stent as an indirect sign), and re-stenosis by two experienced radiologists who blinded to the reports from the conventional angiography. Results : All of stents deployed into symptomatic stenotic lesions. All stents were classified as patent and no re-stenosis, which was correlated with results of conventional angiography. Parts of the stent lumen could be visualized in all cases. On average, 57% of the stent lumen diameter was visible using optimized sharp kernel. Significant improvement of lumen visualization (22%, p<0.01) was observed using the optimized sharp kernel compared with the standard sharp kernel. Inter-observer agreements on the measurement of lumen diameter and density were judged as good, respectively (p<0.05). Conclusion : Sixteen-slice CT using the optimized sharp kernel may provide a useful information for evaluation of lumen diameter patency, and re-stenosis of intracranial stents.
Keywords
Intracranial atherosclerosis; Stents; Multislice CT; CT angiography; Cerebral angiography;
Citations & Related Records

Times Cited By Web Of Science : 7  (Related Records In Web of Science)
Times Cited By SCOPUS : 8
연도 인용수 순위
1 Levy EI, Hanel RA, Bendok BR, Boulos AS, Hartney ML, Guterman LR, et al : Staged stent-assisted angioplasty for symptomatic intracranial vertebrobasilar artery stenosis. J Neurosurg 97 : 1294-1301, 2002   DOI   ScienceOn
2 Nakahara T, Sakamoto S, Hamasaki O, Sakoda K : Stent-assisted angioplasty for intracranial atherosclerosis. Neuroradiology 44 : 706-710, 2002   DOI   ScienceOn
3 Mori T, Kazita K, Chokyu K, Mima T, Mori K : Short-term arteriographic and clinical outcome after cerebral angioplasty and stenting for intracranial vertebrobasilar and carotid atherosclerotic occlusive disease. AJNR 21 : 249-254, 2000   ScienceOn
4 Siemens Inc. Somatom 16 application Guide : Special Protocols. Forchheim : 28-31, 2002
5 Karas SP, Gravanis MB, Santoian EC, Robinson KA, Anderberg KA, King SB 3rd : Coronary intimal proliferation after balloon injury and stenting in swine : an animal model of restenosis. J Am Coll Cardiol 20 : 467-474, 1992   DOI   PUBMED
6 Betriu A, Masotti M, Serra A, Alonso J, Fernández-Avilés F, Gimeno F, et al : Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START) : a four-year follow-up. J Am Coll Cardiol 34 : 1498-1506, 1999   DOI   ScienceOn
7 Lee TH, Kim DH, Lee BH, Kim HJ, Choi CH, Park KP, et al : Preliminary results of endovascular stent-assisted angioplasty for symptomatic middle cerebral artery stenosis. AJNR 26 : 166-174, 2005   ScienceOn
8 Lylyk P, Cohen JE, Ceratto R, Ferrario A, Miranda C : Angioplasty and stent placement in intracranial atherosclerotic stenoses and dissections. AJNR 23 : 430-436, 2002   ScienceOn
9 Maintz D, Grude M, Fallenberg EM, Heindel W, Fischbach R : Assessment of coronary arterial stents by multislice-CT angiography. Acta Radiol 44 : 597-603, 2003   ScienceOn
10 Gomez CR, Misra VK, Campbell MS, Soto RD : Elective stenting of symptomatic middle cerebral artery stenosis. AJNR 21 : 971-973, 2000   ScienceOn
11 Trossbach M, Hartmann M, Braun C, Sartor K, Hahnel S : Small vessel stents for intracranial angioplasty : in vitro evaluation of instent stenoses using CT angiography. Neuroradiology 46 : 459-463, 2004   PUBMED   ScienceOn
12 Bendszus M, Koltzenburg M, Burger R, Warmuth-Metz M, Hofmann E, Solymosi L : Silent embolism in diagnostic cerebral angiography and neurointerventional procedures : a prospective study. Lancet 354 : 1594-1597, 1999   DOI   ScienceOn
13 Lederman RJ, Mendelsohn FO, Santos R, Phillips HR, Stack RS, Crowley JJ : Primary renal artery stenting : characteristics and outcomes after 363 procedures. Am Heart J 142 : 314-323, 2001   DOI   ScienceOn
14 Willinsky RA, Taylor SM, TerBrugge K, Farb RI, Tomlinson G, Montanera W : Neurologic complications of cerebral angiography : prospective analysis of 2,899 procedures and review of the literature. Radiology 227 : 522-528, 2003   DOI   ScienceOn
15 Shin YS, Kim SY, Bang OY, Jeon P, Yoon SH, Cho KH, et al : Early experiences of elective stenting for symptomatic stenosis of the M1 segment of the middle cerebral artery : reports of three cases and review of the literature. J Clin Neurosci 10 : 53-59, 2003   DOI   ScienceOn
16 Mahnken AH, Buecker A, Wildberger JE, Ruebben A, Stanzel S, Vogt F, et al : Coronary artery stents in multislice computed tomography : in vitro artifact evaluation. Invest Radiol 39 : 27-33, 2004   DOI   ScienceOn
17 Waugh JR, Sacharias N : Arteriographic complications in the DSA era. Radiology 182 : 243-246, 1992   DOI   PUBMED   ScienceOn
18 Grzyska U, Freitag J, Zeumer H : Selective cerebral intraarterial DSA. Complication rate and control of risk factors. Neuroradiology 32 : 296-299, 1990   DOI   PUBMED
19 Hahnel S, Trossbach M, Braun C, Heiland S, Knauth M, Sartor K, et al : Small-vessel stents for intracranial angioplasty : in vitro comparison of different stent designs and sizes by using CT angiography. AJNR 24 : 1512-1516, 2003   ScienceOn
20 Maintz D, Seifarth H, Flohr T, Kramer S, Wichter T, Heindel W, et al : Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique. Invest Radiol 38 : 790-795, 2003   PUBMED   ScienceOn
21 Yadav JS, Roubin GS, Iyer S, Vitek J, King P, Jordon WD, et al : Elective stenting of the extracranial carotid arteries. Circulation 95 : 376-381, 1997   DOI   PUBMED   ScienceOn