• 제목/요약/키워드: CT Scans

검색결과 552건 처리시간 0.024초

비골 골절 치료시 일차적 비중격 성형술 (Primary Septoplasty In The Treatment of Nasal Bone Fractures)

  • 유연식;윤을식;이병일;동은상
    • Archives of Plastic Surgery
    • /
    • 제36권1호
    • /
    • pp.61-65
    • /
    • 2009
  • Purpose: Most nasal bone fractures involve the septum; either or both of the ethmoidal perpendicular plate(EPP) and quadrangular cartilage(QC). Unlocked tension from the underlying quadrangular cartilage and poorly reducted bony septum are obstacles to the successful reduction of nasal bone. So we compared the preliminary outcome of septoplasty as a primary treatment with the untreated septum in nasal bone fractures. Methods: We performed a retrospective study of 215 patients underwent reduction of nasal fracture between January 2002 and February 2008. We graded patients into four groups according to the amount of deviation and direction of force by CT. Our indication for septoplasty and combined procedures was the deviation of EPP or QC over 50% from the midline. We interviewed part of the patients by telephone regarding the subjective esthetic and functional outcomes. Results: Forty five of 215 patients (21 percent) underwent septoplasty and combined procedures (cartilage graft, etc) after the informed consent. Patients who underwent septoplasty significantly satisfied with the outcome of esthetic appearance and nasal patency compared with patients who underwent simple closed reduction despite of having septal deviation over 50 percent from the midline. (p < 0.05) Conclusion: Septal surgery and esthetic consideration shoud be made even in simple nasal reductions. And if CT scans reveal severe deviation of septum, septoplasty should be considered as a primary treatment.

Reconstruction of Medial Orbital Wall Fractures without Subperiosteal Dissection: The "Push-Out" Technique

  • Kim, Yong-Ha;Lee, Jin Ho;Park, Youngsoo;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun-Ho;Kim, Tae Gon
    • Archives of Plastic Surgery
    • /
    • 제44권6호
    • /
    • pp.496-501
    • /
    • 2017
  • Background Various surgical methods for repairing medial orbital wall fractures have been introduced. The conventional technique requires total separation of the displaced orbital bones from the orbital soft tissues. However, subperiosteal dissection around the fracture can cause additional damage. The aim of the present study is to introduce a method of reconstructing medial orbital wall fractures without subperiosteal dissection named the "push-out" technique. Methods Six patients with post-traumatic enophthalmos resulting from an old medial orbital wall fracture and 10 patients with an acute medial orbital wall fracture were included. All were treated with the push-out technique. Postoperative computed tomography (CT) was performed to assess the correct positioning of the implants. The Hertel scale and a comparison between preoperative and postoperative orbital volume were used to assess the surgical results. Results Restoration of the normal orbital cavity shape was confirmed by examining the postoperative CT scans. In the old fracture group, the median orbital volume of the fractured side was $29.22cm^3$ preoperatively, and significantly improved postoperatively to a value of $25.13cm^3$. In the acute fracture group, the median orbital volume of the fractured side was $28.73cm^3$ preoperatively, and significantly improved postoperatively to a value of $24.90cm^3$. Differences on the Hertel scale also improved, from 2.13 mm preoperatively to 0.25 mm postoperatively in the old fracture group and from 1.67 mm preoperatively to 0.33 mm postoperatively in the acute fracture group. Conclusions The push-out technique can be considered a good alternative choice for old medial orbital wall fractures with posttraumatic enophthalmos, acute medial orbital wall fractures including large fractured bone segments, and single-hinged greenstick fractures.

L1 요추 압박골절에 대한 진단방사선학 및 보존적 치료 (Diagnostic Radiology and Conservative Management of L1 Lumbar Spine with Compression Fracture)

  • 김재웅
    • 한국식품영양학회지
    • /
    • 제11권2호
    • /
    • pp.165-170
    • /
    • 1998
  • 교통사고로 인한 척추골절 환자 S75에서 손상부위에 따른 진단방사선학 및 보존적 치료 소견을 임상 문헌과 함께 고찰해 본 결과 다음과 같은 결론을 얻었다. 1. 흉요추 좌측방 단순필름에서 L1 요추에 설상변형 정도가 약 10%인 쐐기형 압박골절이 확인되었다. 2. L1 요추의 CT촬영 결과 추체부 전면에 궁형의 불규칙한 골 절편을 관찰할 수 있었으며, T12∼L1는 구조상 손상빈도가 높은 부위로 밝혀졌으며, Denis의 골절형태는 중간주와 후방주가 잘 보존된 전방주의 다발성 압박골절로 분류되었고, Cobb의 척추 만각증은 없었으며, Frankel의 신경손상 분류형태는 E형이었다. 3. 정형외과적 치료방법은 비수술 요법의 보존적 치료를 원칙으로 하였고, 수분·전해질, 영양 및 혈장제 대용으로 공급하는 수액과 함께 브스테로이드성 항염진통제, 근육 이완제를 투여하면서 철저한 침상안정을 유도하였다. 4. 수상후 3주째는 폴리에틸렌 back corset를 착용하고 조기재활을 시도하였으며, 수상 8주 후에도 경도의 불편감이 남아 있었으나, 추시 관찰한 결과 일정기간이 지나면서 점차 척추는 안정성을 찾게 되었다.

  • PDF

Postoperative Course and Recurrence of Chronic Subdural Hematoma

  • Oh, Hyuck-Jin;Lee, Kyeong-Seok;Shim, Jae-Jun;Yoon, Seok-Mann;Yun, Il-Gyu;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권6호
    • /
    • pp.518-523
    • /
    • 2010
  • Objective : Chronic subdural hematoma (CSDH) is known to have a significant recurrence rate. There are different criteria defining the recurrence of CSDH. We evaluated the postoperative course of CSDH and tried to propose the reasonable criteria of recurrence. Methods : We retrospectively examined the medical records and pre- and postoperative CT scans of 149 consecutive patients who underwent surgery from January 2005 to December 2009. Diagnosis was confirmed by CT scanning or MRI. The postoperative courses were either resolved or recurrent. The resolved CSDH was one of the three types; early resolution, delayed resolution, or late resolution. The recurrent CSDH was one of the four types; recurrence without resolution, early recurrence after resolution, late recurrence after resolution, or recurrent-and-resolved type. Results : The CSDH was resolved within 30 days after surgery in 58 (39%) patients, between 1 to 3 months in 62 (42%), and after 3 months in 11 (7%) patients. The CSDH was recurred in 18 (12%) patients. Late resolution or recurrence was more common in the aged. The recurrent hematoma was seen on the same side in 11 patients, on the different side in 7 patients. Recurrence was significantly more common in the thick hematomas. Conclusion : For a working criteria of the recurrence of CSDH, we propose the early recurrence as return of symptoms or reaccumulation of the hematoma after a surgery within 3 months regardless of the location, amount or repeated operations. The late recurrence can be defined as reappearance or enlargement of a liquefied hematoma within the cranial cavity surrounded by the membranes or persistent CSDH beyond 3 months after surgery.

콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발 (Surgical stent for dental implant using cone beam CT images)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Bone remodeling after conservative treatment of nasal bone fracture in pediatric patients

  • Kang, Won Ki;Han, Dong Gil;Kim, Sung-Eun;Lee, Yong Jig;Shim, Jeong Su
    • 대한두개안면성형외과학회지
    • /
    • 제21권3호
    • /
    • pp.166-170
    • /
    • 2020
  • Background: The standard treatment of nasal bone fractures in pediatric patients is closed reduction. Conservative treatment is sometimes performed, but poses a risk of nasal deformity. The aim of this study was to evaluate the outcomes of bone remodeling in pediatric nasal fractures. Methods: Information was extracted from the medical records of patients under 12 years of age who received conservative treatment for a nasal bone fracture and underwent follow-up computed tomography (CT) examinations. The initial fracture and its outcomes over time were graded as excellent, good, or fair according to the malalignment, displacement, or irregularity of the fractured segments. The outcomes of remodeling were evaluated through changes in the grade of the fracture between initial and subsequent CT scans. Results: The review identified 16 patients between March 2015 and December 2019. Their mean age was 6.2 years, and the average follow-up period was 4.9 months. Three of the five patients with a plane I frontal impact showed improved outcomes of remodeling from good to excellent, and the remaining two patients, improved from fair to good. Eight of the 11 patients with plane I lateral impacts showed improved outcomes, from good to excellent, while one patient, improved from fair to good, one patient, improved from fair to excellent, and one patient showed no interval changes. Conclusion: In 15 of these 16 patients with non-severe fractures, the bony contour improved through remodeling, without surgical intervention. Therefore, we suggest that conservative treatment is a feasible option for mild pediatric nasal fractures.

전산화단층영상에서 절치관 및 순측 치조골 폭경에 관한 연구 (The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images)

  • 노양균;장현선;김병옥;김진수
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.145-149
    • /
    • 2006
  • Purpose : To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Materials and Methods : Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal was selected and scanned with 600 DPI resolution. The width of the labial alveolar bone of the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1 The statistical analyses were carried out using SPSS 12.0.1. Results : When the maxillary central incisors remained, the mean labial alveolar bone width were $6.81{\pm}1.41mm,\;6.46{\pm}1.33mm$, and $7.91{\pm}1.33mm$. When the maxillary central incisors were missed the mean width were $5.42{\pm}2.20mm,\;6.23{\pm}2.29mm$, and $7.89{\pm}2.13mm$. Conclusions : The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to nasal cavity revealed statistically significant difference (P<0.05).

  • PDF

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Establishment and evaluation of the VX2 orthotopic lung cancer rabbit model: a ultra-minimal invasive percutaneous puncture inoculation method

  • Wang, Lijuan;Che, Keke;Liu, Zhonghong;Huang, Xianlong;Xiang, Shifeng;Zhu, Fei;Yu, Yu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제22권3호
    • /
    • pp.291-300
    • /
    • 2018
  • The purpose of the present work is to establish an ultra-minimal invasive percutaneous puncture inoculation method for a VX2 orthotopic lung cancer rabbit model with fewer technical difficulties, lower mortality of rabbits, a higher success rate and a shorter operation time, to evaluate the growth, metastasis and apoptosis of tumor by CT scans, necropsy, histological examination, flow cytometry and immunohistochemistry. The average inoculation time was 10-15 min per rabbit. The tumorbearing rate was 100%. More than 90% of the tumor-bearing rabbits showed local solitary tumor with 2-10 mm diameters after two weeks post-inoculation, and the rate of chest seeding was only 8.3% (2/24). The tumors diameters increased to 4-16 mm, and irregularly short thorns were observed 3 weeks after inoculation. Five weeks post-inoculation, the liquefaction necrosis and a cavity developed, and the size of tumor grew further. Before natural death, the CT images showed that the tumors spread to the chest. The flow cytometry and immunohistochemistry indicated that there was less apoptosis in VX2 orthotopic lung cancer rabbit model compared to chemotherapy drug treatment group. Minimal invasive percutaneous puncture inoculation is an easy, fast and accurate method to establish the VX2 orthotopic lung cancer rabbit model, an ideal in situ tumor model similar to human malignant tumor growth.

A Morphometric Analysis of the Foramen Ovale and the Zygomatic Points Determined by a Computed Tomography in Patients with Idiopathic Trigeminal Neuralgia

  • Hwang, Sung-Hyuk;Lee, Myung-Ki;Park, June-Woo;Lee, Jae-Eon;Cho, Chang-Won;Kim, Dae-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권3호
    • /
    • pp.202-205
    • /
    • 2005
  • Objective : The purpose of this study is to measure the dimensions of foramen ovale and to localize the zygomatic point using computed tomography[CT] in Korean adults with idiopathic trigeminal neuralgia. Methods : Facial axial CT scans using the orbitomeatal plane were performed in 67patients [39males and 28females; mean age 58.8years] with idiopathic classic trigeminal neuralgia. We measured the size of the foramen ovale and localized the zygomatic point which was a skin marker over the ipsilateral zygoma that approximates the lateral projection of a straight line joining the centers of the two foramen ovale. Results : The axial dimensions of the foramen ovale on the orbitomeatal plane were of average length : $8.18{\pm}0.82mm$ [range $6.9{\sim}11.5mm$]. width : $4.06{\pm}0.86mm$ [$2.5{\sim}5.7mm$]. The average distance between the external acoustic meatus and the zygomatic point was $21.64{\pm}1.99mm$ [$16.3{\sim}25.0mm$] and the average distance of anterior margin of condylar process of mandible to zygomatic point was $4.29{\pm}1.19mm$ [$1.0{\sim}7.0mm$]. Conclusion : The anatomical understandings including the size of the foramen ovale and localization of the zygomatic point could be helpful in determining a plan of percutaneous approaches to foramen ovale.