• 제목/요약/키워드: CT Image

검색결과 1,672건 처리시간 0.031초

Accuracy of image registration for radiation treatment planning using a brain phantom

  • Jin, Ho-Sang;Suh, Tae-Suk;Song, Ju-Young;Juh, Ra-Hyeong;Kwark, Chul-Eun;Lee, Hyoung-Koo;Choe, Bo-Young
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.106-106
    • /
    • 2002
  • Purpose: The purposes of our study are (1) to develop a brain phantom which can be used for multimodal image registration, (2) to evaluate the accuracy of image registration with the home-made phantom. Method: A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using chamfer matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods for CT, MR imaging and Pb rods for SPECT imaging. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process.

  • PDF

뇌 CT 영상의 대칭성을 고려한 관심영역 중심의 효율적인 의료영상 압축 (An Efficient Medical Image Compression Considering Brain CT Images with Bilateral Symmetry)

  • 정재성;이창훈
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.39-54
    • /
    • 2012
  • 오늘날 의료정보화 수준향상과 디지털 병원화의 흐름에 따라 PACS는 의료기관의 핵심 인프라 중 하나로 자리매김하였다. 이와 함께 생산되는 디지털 의료영상의 종류 및 의료영상 데이터가 양적으로 급증하고 있으며, 이는 의료영상 데이터의 효과적인 보관을 위한 의료영상 압축을 중요한 요소로 부각시킨다. 현재 의료영상에 관한 사실상의 표준인 DICOM 규격에서는 의료영상 압축을 위하여 무손실 압축기법인 RLE를 명시하고 있으나, 무손실 범용 압축기법인 RLE는 인체의 대칭성을 가지는 많은 의료영상에 적용하면 높은 압축율 기대하기 힘들다. 이 논문에서는 다양한 의료영상 중 대칭 특성을 크게 내포하는 뇌 CT 영상을 대상으로 하여 영상 내 관심영역을 검출하고 대칭특성에 따라 영상의 픽셀 값을 재코딩하는 전처리 하고 영상을 압축하는 기법을 제안한다. 실험에 의하면, 제안한 기법은 RLE 압축과 영상 내 관심영역을 검출하지 않고 압축할 때와 비교하여 높은 압축률을 보인다.

ADMIRE 반복적 재구성 파라메터에 따른 CT 영상의 특성 및 무참조 기반 화질 평가: 선행연구 (Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters: A Pilot Study)

  • 박보민;서유진;강성현;심지나;김하진;임세원;이영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.175-182
    • /
    • 2024
  • Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient images were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;손현수;이주영;박훈희
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.93-101
    • /
    • 2015
  • SPECT영상에서 산란계수는 정량적 계수오차와 영상품질 저하의 요인이다. 이에 다양한 산란보정(Scatter Correction, SC)방법이 연구되어 왔으며, 본 연구에서는 기존의 에너지창(Energy Window, EW) 기반 SC(EWSC)와의 비교로 SPECT/CT에서 사용되는 CT 기반 SC(CTSC)의 정확성을 평가하고자 한다. 중앙에 열소막대(hot rod, 74.0 MBq)를 설정한 Triple line insert 팬텀의 내부에 산란계수의 영향이 없는 기준영상의 획득을 위하여 공기를 채운 후 SPECT /CT영상을 획득하였고, 같은 조건에서 산란계수의 영향을 유도하기 위하여 공기대신 물을 채운 후 SPECT/CT영상을 각각 별도로 획득하였다. 두 조건 모두 Astonish(iterative : 4, subset : 16) 재구성 방법과 CT감쇠보정을 공통 적용하였고, 물을 채운 영상에 비산란보정(NSC), EWSC, CTSC 3가지 유형의 산란보정방법을 사용하였다. EWSC를 위하여 주(=peak) 에너지창(140 keV, 20%) 이외에 보조 에너지창 9개를 추가 설정한 후 영상을 동시 획득하였고, EWSC의 종류는 DPW(dual photopeak window) 10%, DEW (dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% 5가지를 사용하였다. 일차(primary)계수의 변동이 없는 조건하에, 두 조건의 영상에 VOI를 그려 총계수를 측정한 후 총계수 중 산란계수의 비를 %SF(percent scatter fraction)로 구하고, 공기를 채운 영상을 기준으로 물을 채운 영상과의 계수차이를 %NMSE (per cent normalized mean-square error)로 평가하였다. 공기를 채운 영상을 기준으로 각 산란보정방법이 적용된 물을 채운 영상의 %SF는 NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57로 CTSC에서 제거된 산란계수가 가장 많았으며, %NMSE는 NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35로 CTSC에서 가장 낮게 나타났다. SPECT/CT영상에서 실험에 사용된 각 산란보정 방법의 적용은 산란계수의 영향으로 발생된 정량적 계수오차를 개선시킬 수 있었다. 특히, CTSC의 경우 기존의 EWSC방법들과 비교하여 가장 낮은 %NMSE (=0.35)를 보여 비교적 정확한 산란보정이 가능하였다.

  • PDF

마이크로 CT를 이용한 BALB/C(흰쥐) 간문맥의 미세혈관 조영 영상 (Microvascular Contrast Image in Portal Veins of Rat using Micro-CT)

  • 이상호;임청환;정홍량;한범희;모은희;채규윤
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.259-266
    • /
    • 2010
  • 고해상도 엑스선 영상장치인 마이크로 CT를 이용, 흰쥐 간의 전체적인 문맥상과 각 간엽(lobe)의 미세혈관구조를 관찰하여 4개 분절 간엽의 구조를 영상화 하였고, 단축면상의 데이터를 3D영상으로 재구성한 미세혈관 구조의 입체적인 영상을 획득할 수 있는 마이크로 CT에 대한 유용성을 알아보고자 하였다. 5마리의 간 중에서 손상이 가장 적은 1개의 간을 4 개의 분절 간엽으로 각각 절단하여 문맥의 미세구조를 이차원으로 구성하였으며, MIP기법을 이용하여 간 문맥 전체 미세혈관의 3D영상을 얻었으며, 각 간엽의 미세혈관은 6분지까지 관찰할 수 있었다. 6 분지까지의 크기를 측정한 결과 평균치는 1 branch : $0.51mm{\pm}0.08$, 2 branch : $0.32mm{\pm}0.12$, 3 branch : $0.23mm{\pm}0.11$, 4 branch : $0.19 mm{\pm}0.08$, 5 branch : $0.13mm{\pm}0.06$, 6 branch : $70.5{\mu}m{\pm}14.1$ 로 측정되었다. 본 연구의 실험 결과에서 획득한 3차원의 입체 영상과 미세혈관 구조의 발견은 향후 고해상력의 영상을 얻을 수 있는 마이크로 CT가 많이 이용될 수 있을 것으로 기대된다.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

다중영상기기의 응용 소프트웨어 (Multimodality and Application Software)

  • 임기천
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.153-163
    • /
    • 2008
  • 다중영상기기는 1990년대 초에 처음 개발되어 현재 주요 영상 장비 회사에서 상품으로 개발되어 판매되고 있다. 단순한 소프트웨어적인 정합과 융합을 통해 해부학적 영상과 기능적 영상의 상호 보완하는 단계에서 발전하여 하드웨어적으로 정합하는 하드웨어의 개발은 새로운 연구의 시작이다. 다중영상기기의 발전 이전에는 해부학적 구조를 보여주는 영상 장비와 기능적 영상을 표현하는 장비가 각각 고 분해능과 고 해상도로 많은 발전을 이루어 왔다. 현재는 각 영상 장비의 특징을 살려 효과적으로 결합시킨 다중영상기기의 개발이 활발하게 이루어지고 있다. 다중영상기기는 단순하게 두 장비를 결합시키는 개념에서 기능적 영상에서 필요한 감쇠 보정을 하면서 동시에 해부학적 위치를 융합 영상 형태로 표현하는 새로운 영상 장비로 발전하고 있다 다중영상기기의 특징을 살릴 수 있는 프로토콜이 개발되고 하드웨어적으로도 상호 보완적으로 결합되고 있다. 실제로 PET/CT와 같은 다중영상기기는 임상적으로 중요한 역할을 하고 있으며 PET 영상기기를 대체하고 있다. PET/CT 스캐너는 PET에서 나오는 기능적 영상과 CT에서 나오는 해부학적 영상뿐만 아니라 융합 영상을 함께 보여 주므로 임상적으로 유용한 정보를 제공하고 있다. 현재 SPECT/CT는 아직 보급이 많이 되지 않았으나 PET/CT와 같이 임상적으로 유용한 SPECT와 CT 장비가 결합된 상품들이 나오고 있어 그 시장이 점점 성장할 것으로 기대된다. 다중영상기기는 각각의 단독 영상장비에서 갖고 있는 문제뿐만 아니라 두 영상 장비를 결합시키므로 인해 새로운 문제들이 발생하고 있다. 대표적으로 호흡에 의한 움직임, 조영제의 영향, 금속 물질의 영향과 환자의 피폭에 관한 문제가 있다. 이를 해결하기 위해 새로운 프로토콜과 프로세싱 방법이 개발되고 있다. 뇌를 동시에 촬영할 수 있는 PET/MR의 개발은 뇌 과학에 많은 발전을 줄 것으로 기대된다. PET/MR의 개발은 PET/CT 에서 촬영한 영상의 일부분을 대체할 것으로 예상된다. MR 영상이 CT 영상보다 우수한 분해능을 보이는 분야에서는 PET/MR을 이용한 검사와 연구가 활발하게 진행될 것으로 보인다. 해부학적 영상과 기능적 영상을 결합시킨 융합 영상을 함께 제공하는 다중영상기기는 환자의 질병을 진단뿐만 아니라 치료 후의 효과를 보는데 있어서 중요한 역할을 할 것으로 기대된다. 또 앞으로 검사 목적에 맞는 다양한 다중영상기기의 개발이 이루어질 것으로 기대된다.

고급 모델 반복 재구성법 (ADMIRE)을 사용한 CT 영상에서의 노이즈 레벨 및 블라인드 화질 평가 (Evaluation of Noise Level and Blind Quality in CT Images using Advanced Modeled Iterative Reconstruction (ADMIRE))

  • 심지나;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.203-209
    • /
    • 2022
  • 전산화단층촬영장치 (Computed Tomography, CT)의 화질을 유지하면서 방사선량을 낮추기 위한 대표적인 방법 중에 하나는 모델기반 반복 재구성법 (Model-Based Iterative Reconstruction, MBIR)을 사용하는 것이다. 본 연구에서는 MBIR의 대표적인 모델로 잘 알려진 고급 모델 반복 재구성법 (Advanced Modeled Iterative Reconstruction, ADMIRE)의 강도를 조절하여 영상의 화질을 평가하고자 하였다. 연구는 팬텀을 사용하여 수행되었고, ADMIRE의 강도를 1에서부터 5까지 1 단위로 조절하면서 CT 영상을 획득하였다. 정량적 평가는 변동 계수 (coefficient of variation, COV)와 대조도 대 잡음비 (contrast to noise ratio, CNR)를 활용한 노이즈 레벨과 natural image quality evaluator (NIQE)와 blind/referenceless image spatial quality evaluator (BRISQUE)의 블라인드 품질 평가를 수행하였다. 결과적으로 노이즈 레벨 및 블라인드 품질 평가 결과에서 모두 ADMIRE의 강도가 높아질수록 우수한 결과가 도출되었다. 특히, COV와 CNR은 ADMIRE 1에 비하여 5에서 각각 1.89 및 1.75배 향상됨을 확인하였고, NIQE와 BRISQUE는 재구성 강도 1에 비하여 5에서 각각 1.35 및 1.22배 향상됨이 증명되었다. 결론적으로 ADMIRE의 재구성 강도는 CT 영상의 노이즈 레벨 및 전체적인 화질 평가에 큰 영향을 끼친다는 것을 증명하였다.

CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가 (Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT)

  • 김동현;고성진;강세식;김정훈;최석윤;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권6호
    • /
    • pp.331-338
    • /
    • 2013
  • 간질환을 주소로 추적검사를 위해 내원한 CT(Computer Tomography, 이하 CT) 검사자를 대상으로 체질량 지수와 관전압 변화에 따른 영상의 화질 및 방사선 피폭선량변화에 대하여 알아보고자 하였다. 2010년 3월부터 2011년 6월까지 부산 P대학병원에 복부 CT 를 검사한 환자 중 체질량지수(Body Mass Index, 이하 BMI)가 25이하인 환자를 대상으로 하였고 대상자는 48명이었다. 영상의 질의 객관적 평가로 신호대 잡음비와 유효선량을 비교하였다. 복부 영상의 화질평가는 영상의학과 의사2명이 한국의료영상품질관리원에서 선정한 임상영상 평가의 기준을 근거로 해 1점에서 20점까지 점수를 매겨 평가하였다. 피폭선량분석에서 CTDIvol값은 관전압이 100kVp일 때 120kVp보다 약44.1%가 감소하였다. 그리고 유효선량은 관전압 100kVp일 때 120kVp보다 약43%가 감소하였다. 영상의 화질 평가는 반복적으로 CT검사를 위해 내원한 총48명의 검사자 영상 중 Good 1명, Excellent 47명으로 평가되었다. 추적검사를 시행하는 환자 중 BMI지수가 25이하인 환자들을 대상으로 저관전압을 적용한 복부 CT검사 시 영상의 질적 저하없이 진단 가치가 있는 영상의 획득과 피폭선량 감소효과를 얻을 수 있다고 사료된다.

임플란트 시술환자에 대한 두경부 CT검사 영상 평가 (Head & Neck CT Scan Image Evaluation for Implant Surgery Patients)

  • 황형석;황형석;임인철
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.843-849
    • /
    • 2023
  • 본 연구는 임플란트 시술한 환자에 대한 두경부 CT 영상을 4개의 알고리즘(Standard, Soft, Bone, Detail)을 재구성하여 Noise, SNR, CNR 측정값을 정량적으로 분석한 후 최적의 알고리즘을 알아보고자 하였다. 분석방법으로는 Image J 프로그램을 이용하여 재구성한 영상에 관심영역(Region of interest)을 통하여 픽셀값을 계산하였다. Noise, SNR, CNR은 측정부위를 영상에서 인두, 깨물근, 귀밑샘이 있는 지점에 관심영역을 측정하고 mean값과 SD값을 구하였다. SNR과 CNR의 값은 주어진 식에 의거하여 산출하였다. 결과적으로 Standard 알고리즘에서 노이즈는 가장 낮게 나타났으며 SNR 또한 가장 높게 나타났다. CNR은 Soft 알고리즘에서 가장 높게 나타났으나 Standard 알고리즘과는 별 차이가 없는 것으로 나타났다. 따라서 두경부 CT검사에서 구강내 임플란트 착용한 환자 검사에서 Standard 알고리즘이 최적의 알고리즘이라고 사료되며 이 연구의 자료가 두경부 CT검사에서 영상 평가하는데 기초자료로 사용되기를 바라며 다양한 알고리즘 변화로 영상의 질을 더 높일 수 있는 계기가 될 것으로 판단된다.