• Title/Summary/Keyword: CT 조사

Search Result 654, Processing Time 0.027 seconds

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.

Study of the Production Method of the Framework of Lacquerware Inlaid with Mother-of-pearl Using X-ray Computed Tomography (엑스선 컴퓨터 단층면 조사를 통한 나전연상 백골의 제작기법 연구)

  • Park, Youngman;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.75-80
    • /
    • 2020
  • X-ray computed tomography (X-ray CT), which is often applied to the investigation of the interior structures of cultural properties, is very useful for studying production methods used in lacquerware that would otherwise be difficult to observe with the naked eye. Lacquerware inlaid with mother-of-pearl is an important subject in the study of traditional Korean craft. However, it can be a challenge to specify the production methods used in the framework of a lacquerware item unless the object has been structurally damaged. Studies of lacquerware inlaid with mother-of-pearl have thus far focused on the techniques of lacquering and of inlaying the mother-of-pearl. Production methods for the framework of lacquerware has received little academic attention. This study conducted X-ray CT on a lacquerware item from the Joseon period to reveal the materials and woodworking techniques used for the framework. The study revealed that softwood was used for the framework, and the post (gidungmok) and apron (soemok) were joined using a three-way miter joint (sambang yeongwi jjaim). Other pieces were joined with nails.

Improved Specificity of $^{18}F-FDG$ PET/CT for Lymph Node Staging of Non-Small Cell Lung Cancer Considering Calcified Lymph Node as Benign (비소세포 폐암에서 석회화 림프절을 양성으로 보았을 때 $^{18}F-FDG$ PET/CT의 특이도 향상)

  • Kwon, Seong-Young;Seo, Young-Soon;Min, Jung-Joon;Song, Ho-Chun;Na, Kook-Joo;Choi, Chan;Kim, Young-Chul;Kim, Yun-Hyun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • Purpose: We evaluated the diagnostic value of $^{18}F-FDG$ PET/CT (PET/CT) in lymph node staging of non-small cell lung cancer (NSCLC) considering calcification and histologic types as well as FDG uptake. Materials and Methods: Fifty-three patients (38 men, 15 women; mean age, 62 years) with NSCLC underwent surgical resection (tumor resection and lymph node dissection) after PET/CT. After surgery, we compared PET/CT results with the biopsy results, and analyzed lymph node metastases, based on histologic types. PET diagnosis of lymph node metastasis was determined by maximum SUV (maxSUV) > 3.0, and PET/CT diagnosis was determined by maxSUV > 3.0 without lymph node calcification. Results: By PET diagnosis, the sensitivity, specificity, and accuracy of overall lymph node staging were 45% (13 of 29), 91% (228 of 252), and 86% (241 of 281). Specificity was 91% in both squamous cell carcinoma and adenocarcinoma, while sensitivity was 71% in squamous cell carcinoma and 36% in adenocarcinoma. When we excluded calcified lymph node with maxSUV > 3.0 from metastasis by PET/CT diagnosis, specificity improved to 98% in squamous cell carcinoma and 97% in adenocarcinoma. The degree of improvement was not dependent on histologic types. Conclusion: PET/CT improved specificity of lymph node staging by reducing false positive lymph node regardless of histologic types of NSCLC.

Clinical Significance of Incidental Asymmetric Palatine Tonsillar Uptake on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT에서 우연히 관찰되는 구개편도의 비대칭적 섭취증가의 임상적 의의)

  • Chae, Sun-Young;Baek, So-Ra;Ryu, Jin-Sook;Moon, Dae-Hyuk;Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.402-410
    • /
    • 2009
  • Purpose: The aim of this study was to determine the incidence and malignant rate of incidental asymmetric palatine tonsillar uptake (ATU) on $^{18}F$-FDG PET/CT in various clinical indications and to evaluate the clinical and PET/CT findings suggesting malignancy. Materials and Methods: We retrospectively reviewed a total of 2,901 patients ($58.4{\pm}12.3$ yrs, range 20~88 yrs, M:F = 1,841:1,060) who underwent $^{18}F$-FDG PET/CT during an 1-year period with various indications except primary tonsillar cancer and lymphoma evaluation. On $^{18}F$-FDG PET/CT, metabolic abnormality of the palatine tonsil and cervical lymph node were visually assessed. ATU was defined as increased palatine tonsillar uptake with diffuse, focal, or irregular pattern compared to contralateral side. The incidence and malignant ratio of ATU were evaluated according to clinical and PET/CT findings. Results: Of 2,901 cases, 290(10,0%) showed ATU. The incidence of ATU showed seasonal variation and was high in the winter (12.1%). Of 209 cases with ATU confirmed pathologically and/or clinically, five (2.4%) were malignant lesions. ATU with irregular uptake pattern (2/2) and in cases referred for cervical lymph node metastasis of unknown origin (3/5) were frequently associated with malignant lesion (p<0.05). Conclusion: ATU was not infrequently observed on $^{18}F$-FDG PET/CT, and the malignant risk of ATU was low. However, ATU with cervical lymph node metastasis or with irregular pattern on PET/CT would be further evaluated by the histopathologic examination.

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

Determination of Target Position with BRW Stereoatic Frame in non-orthogonal CT scans (비직교성 전산화단층촬영에서 뇌정위수술용 좌표계를 이용한 표적위치 결정)

  • Park, Tae-Jin;Kim, Ok-Bae;Son, Eun-Ik
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.53-62
    • /
    • 1992
  • Stereotactic implantation of intracranial lesions, and the development of stereotactic convergent irradiation, radiosurgery, techniques have to obtain the accurate coordinates of the tumor locations and that of critical organ. Computed tomography(CT) provides relatively precise imformations of tumor localization and surround the normal organs for conventional radiotherapy. This CT image use to extend for stereotactic radiosurgery procedures. Since the convergent irradiation technique in linear accelerator requires the target center coincident with gantry isocenter or radosurgery frame, the target coordinates must be described in accurately. We used the BRW stereotactic system for describing the target position in CT images This algorithm provides the coordinate conversions for orthogonal or non-orthogonal CT scan image. In this experiments, the target positions have shown the small discripancy within :to.3mm uncertanty in several known target positions in the phantom through the provided programs and it compared to that of BRW stereotactic systems.

  • PDF

Effect of Suboptimal Temperature Incubation on the Resistance of Lactobacillus acidophilus CT 01 to Storage and Drying (저온배양에 따른 Lactobacillus acidophilus CT 01의 저장 및 건조에 대한 저항성)

  • Yu Keun-Hyung;Kwon Il-Kyoung;Kim Gur-Yoo
    • Food Science of Animal Resources
    • /
    • v.25 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This study was carried out to determine the storage, cryotolerance, heat and drying resistance, when Lactobacillus acidophilus CT 01 isolated from preweaned piglet feces growing at suboptimal temperature. L. acidophilus CT 01 suboptimal temperature incubated for 48 hours had the slowest growth rate at 22℃ but the highest viable cell number after 36 hours at 22℃, with 1.3×10/sup 9/ CFU/mL. In case of 4 and 20℃ storage, the suboptimal temperature incubated groups had a viability higher than the control (p<0.01). The cryotolerance of suboptimal temperature incubated L. acidophilus CT 01 was a higher than the control (p<0.01). When L. acidophilus CT 01 was heat treated at 60℃ for 15 minutes and 30 minutes, the suboptimal temperature incubated L. acidophilus CT 01 at 22℃ had a viability higher more than the control (p<0.01). L. acidophilus CT 01 incubated suboptimal temperature was inoculated by 30% to the carrier, and dried at 50℃ for 12 hours had the highest viability in the suboptimal temperature incubated L. acidophilus CT 01 at 28℃.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

The Effects of $Ca^{2+}$on the Interaction of Nonionic Surfactant with Iodine in Aqueous Solution (수용액 중에서 비이온성 계면활성제와 요오드간의 상호작용에 미치는 $Ca^{2+}$의 영향)

  • Kwon Oh-Yun;Paek U-Hyon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.621-626
    • /
    • 1992
  • The effects of $Ca^{2+}$ ion on the charge transfer(CT) interaction of $4-(C_9H_{19})C_6H_4O(CH_2CH_2O)_{40} [NP-(EO)_{40}]$ with iodine in aqueous solution were investigated by UV-visible spectrophotometer. Maximum absorption wavelengths to the CT interaction were in the vicinity of 390 nm, and by the addition of $Ca^{2+}$ ion shifted toward 370 nm. Above CMC, the intensity of the CT interaction by the addition of $Ca^{2+}$ ion were increased and then decreased. The increase in the intensity of CT band were attributed to the increase of the donor-acceptor overlap with iodine caused by the compactness of micelle in the presence of $Ca^{2+}$ ion. These phenomena suggest that the linear oxyethylene(EO) chains, relatively free to assume various configuration in aqueous solution, could form a pseudo-crown ether structures capable of forming complexes with $Ca^{2+}$ ion.

  • PDF