• Title/Summary/Keyword: CT (computerized tomography)

Search Result 180, Processing Time 0.025 seconds

A Case of Pulmonary Alveolar Proteinosis (폐포단백증 1예)

  • Woo, Dae-Hyung;Park, Jung-Eun;Ryu, Yung-Ha;Kim, Hyun-Jung;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2010
  • Pulmonary alveolar proteinosis (PAP) is a rare disorder that's characterized by accumulation of surfactant components in the alveolar space. Idiopathic PAP is recognized as an autoimmune disease that's due to impaired alveolar macrophage function and this caused by autoantibodies against granulocyte-macrophage colony-stimulating factor (GM-CSF). We report here a case of pulmonary alveolar proteinosis that was deemed interstitial lung disease at the initial diagnosis. A 61-year-old man presented with intermittent blood tinged sputum and dyspnea on exertion. The man was a painter for 30 years and he had a 10 pack-years smoking history. Chest computerized tomography (CT) revealed multifocal ground-glass opacity with interstitial thickening at both lungs. His pulmonary function tests and methacholine test revealed non specific results. He was diagnosed with interstitial lung disease on the basis of the chest CT finding and occupational history. However, seven months later, his symptoms progressed. Follow-up chest CT was performed. Wedge resection via video-assisted thoracoscopic surgery (the anterior basal segment of the left lower lobe) was done. Microscopic examination showed large groups of alveoli with excessive amounts of surfactant and a complex mixture of protein and lipid (fat) molecules. Finally, he was diagnosed as having pulmonary alveolar proteinosis.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

False Vocal Fold Hypertrophy Caused by Thyroid Cartilage Inward Bowing (갑상연골 내굴곡에 인한 가성대의 비대)

  • Kwon, Jin Ho;Choi, Byeong Il;Hong, Hyun Jun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.1
    • /
    • pp.51-54
    • /
    • 2013
  • False vocal fold hypertrophy caused by diverse pathologic lesion, such as laryngeal amyloidosis, laryngeal lipidosis, laryngocele, saccular cyst and sulcus vocalis. False vocal fold hypertrophy, however, is also caused laryngeal structure deformity, irrespective of pathologic lesions. In this article, we report some cases of false vocal fold hypertrophy caused by inward bowing of thyroid cartilage. At the clinic of the department of otorhinolaryngology in Gangnam Severance Hospital, with 3 male complained of hoarseness as subjects, and comfirmed of false vocal fold hypertrophy using the stroboscopy and larynx CT we checked vocal fold and laryngeal structure. Three patients with apparent hypertrophy of false vocal fold were investigated with computerized tomography (CT). In all patients, marked concavity of thyroid cartilage was revealed in CT scan at the level of the false vocal fold, and this deformity of the thyroid cartilage seemed to cause a protrusion of false vocal fold which taken as hypertrophy in stroboscopy. Careful palpation of the larynx and a CT scan taken at the level of the false vocal fold should be useful in determining whether hypertrophy of the false vocal fold is pathologic. For the next articles, It is necessary to discuss for the cause, diagnosis, treatment and prevention of inward bowing of thyroid cartilage.

  • PDF

The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity (소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구)

  • Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1082-1089
    • /
    • 2005
  • Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.

The Utility of Chest CT in Staging of Esophageal Cancer (식도암의 병기 결정에 있어 흉부 CT의 유용성)

  • 홍성범;장원채;김윤현;김병표;최용선;오봉석
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.992-998
    • /
    • 2004
  • Background: The decision of staging of esophageal cancer have great effect on the resectability of the lesion and estimation of the patient's prognosis. Today, CT is one of the most popular modality for staging of esophageal cancer. However, it has some limitations because of false-positive or false-negative findings on cancer staging. The purpose of this study was to analyze the efficacy of CT in preoperative staging of esophageal cancer. Material and Method: We retrospectively analysed the difference of staging of esophageal cancer between CT and histopathological findings for the 114 patients with histologically proven esophageal cancer who underwent operation at the department of thoracic and cardiovascular surgery, Chonnam national university hospital, between January 1999 and June 2003. We evaluated the efficacy of chest CT in the staging of esophageal cancer compared to postoperative histopathologic findings by calculating sensitivity, specificity, accuracy, and reproducibility of chest CT to detect abnormality. Result: The reproducibilities between chest CT and histopathologic findings were 0.32 (p<0.01) for primary tumor (T), 0.36 (p<0.01) for lymph node invasion (N), and 0.62 (p<0.01) for distant metastasis (M). The reproducibilities between chest CT and histopathologic findings for lymph node invasion (N) and distant metastasis (M) were superior to that of primary tumor (T). The accuracy of primary tumor (T) was 65.8% and 98.2% in group III and IV, which was significantly higher than that of group I and II (78.9% and 62.3%). In general, specificity of chest CT for TNM staging was superior to sensitivity. Conclusion: In conclusion, preoperative CT scanning can provide important information on lymph node invasion and metastasis of lesion than primary tumor invasion.

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

3-D CT Image Study of Effect of Glenoid Fossa on Menton Deviation (하악 관절와의 형태가 하악 이부편위에 미치는 영향에 관한 3차원 영상 연구)

  • Cho, Jin-Hyoung;Lee, Kyung-Min;Park, Hong-Ju;Hwang, Hyeon-Shik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.337-345
    • /
    • 2011
  • Purpose: The purpose of this study was to define the relation of the degree of menton deviation and 3-D CT (computerized tomography) measurements of the glenoid fossa and the mandible, which are considered to have an influence on menton deviation. Methods: The CT images were obtained in 60 adults and these were transmitted to a computer and reconstructed using computer software. According to the degree of the menton deviation, which was measured on the posteroanterior cephalogram, the subjects were divided into the menton deviated group (30 adults) and the symmetry group (30 adults). A total of 11 measurements that might have an effect on menton deviation were determined and these were measured in the right and left sides using the function of 3-D measurement in the computer program. The 11 measurements consist of 6 measurements in the glenoid fossa (vertical position of the glenoid fossa and articular eminence, the sagittal position of the glenoid fossa and articular eminence, the depth of the glenoid fossa, and the anterior angle of the glenoid fossa), and 5 measurements in the mandible (ramus length, frontal ramal inclination, lateral ramal inclination, body length, body height). Results: The comparison of the differences between the menton deviated and symmetry groups and correlation analysis on the degree of menton deviation were carried out. The results of comparison of the right and the left difference between the menton deviated and symmetry groups showed that the vertical position and depth of the glenoid fossa were significantly increased in the menton deviated group. Conclusion: The results of the present study show that consideration of the shape and position of the glenoid fossa is necessary for making the diagnosis and administering proper treatment in facial asymmetry patients and especially growing patients.

A Case of Rasmussen Aneurysm Treated by Pulmonary Arterial Embolization (폐동맥색전술로 치료된 Rasmussen 동맥류 1예)

  • Park, Sung-Oh;Ko, Hyuk;Kim, Su-Hee;Park, Wan;Lee, Deck-Hee;Ryul, Dae-Sik;Jung, Bock-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • A 42 year-old male with a history of multidrug-resistant pulmonary tuberculosis suddenly developed massive hemoptysis. Embolization of a bronchial artery branch and the collateral systemic arteries did not resolve the recurrent bleeding. Spiral computerized tomography(spiral CT) of the chest showed contrast enhanced nodules within a large cavity at the left lower lobe in the arterial phase suggesting a Rasmussen aneurysm. A pulmonary angiogram showed abnormal vascular nodules at that site. Coils were deployed at both the proximal and distal vessels of this aneurysmal sac for embolization. Transcatheter arterial embolization is a safe and effective means of controlling bleeding from this pulmonary arterial pseudoaneurysm. Here we report a case of a Rasmussen aneurysm diagnosed by spiral CT, which was successfully treated by pulmonary arterial embolization with a coil.

  • PDF

Incidence rate of Aneurysmal SAH in Gwangju City and Jeollanamdo Province in 2007

  • Seo, Bo-Ra;Kim, Tae-Sun;Joo, Sung-Pil;Jang, Suk-Jung;Lim, Jun-Seob;Oh, Chang-Wan
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.124-127
    • /
    • 2010
  • Objective : The incidence of subarachnoid hemorrhage (SAH) worldwide varies considerably. In spite of many reports about the incidence of SAH, there has been no report about the incidence of SAH on the basis of the Korean population. The purpose of this hospital-based study was to assess the actual incidence rates of aneurysmal SAH in Gwangju city and Jeollanamdo province. Methods : All cases of SAH confirmed by computerized tomography (CT) between January 2007 and December 2007 were selected for analysis. For the data collection, three major training hospital and ten general hospitals working the CT in Gwangju city and four major general hospitals in Jeollanamdo province participate in this study. Results : According to the official census of Korea, the population was 1,413,444 in Gwangju city and 1.929,836 in Jeollanamdo province in 2007. There were 163 patients in Gwangju city and 266 patients in Jeollanamdo province confirmed SAH by CT in 2007. The crude and the age- and sex-adjusted annual incidence rates per 100,000 population for all ages in Gwangju city were 11.5 and 12.4 for aneurysmal SAH and in Jeollanamdo province were 13.8 and 10.8. The incidence was higher in women and increased with age. The gender distribution varied with age. At young ages. the incidence was higher in men while after the age of 40 years, the incidence was higher in women. Conclusion : In the present study, the age- and sex-adjusted annual incidence rates is 11.8 in Gwangju city and Jeollanamdo province. The incidence was higher in women and increased with age.

Biomechanical Evaluation of Cement type hip Implants as Conditions of bone Cement and Variations of Stem Design (골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가)

  • Park, H.S.;Chun, H.J.;Youn, I.C.;Lee, M.K.;Choi, K.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.212-221
    • /
    • 2008
  • The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors. The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters. The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FE A using commercial stem model (Zimmer's V erSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.