• Title/Summary/Keyword: CT장치

Search Result 316, Processing Time 0.029 seconds

A Study on Perception by Examinees of the Health Promotion Center Institutions about Exposure to Radioactivity (건강검진센터에 내원한 환자의 방사선피폭에 대한인지도 조사)

  • Yeo, Jin-Dong;Jeon, Byeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.457-468
    • /
    • 2016
  • The purpose of this study was to investigate factors of perception by inpatients of the Medical Examination institutions about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 72.0% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 63.5% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 29.0% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.

A Study on Perception by Examines of the Radiology Department about Exposure to Radioactivity (영상의학과 내원 환자의 방사선피폭 인지도에 관한 연구)

  • Yeo, Jin Dong;Ko, In ho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.321-331
    • /
    • 2013
  • The purpose of this study was to investigate factors of perception by inpatients of the radiology department about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 65.5% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 56.1% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 26.3% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.

Evaluation of Feed Values of Korean Straws Using Pressure Transducer (Auto-Pressure Transducer를 이용한 국내산 고간류의 사료가치평가)

  • Lee, Sang S.;Ha, J. K.;Chang, M. B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.241-250
    • /
    • 2003
  • Accurate and rapid evaluation of the nutritional quality of Korean straws is important because of the recent increase in the use of these feedstuffs in Korean. The aim of the study was to establish with relationships between ruminal fermentation of Korean straws and in vitro gas production using a pressure transducer. The pressure transducer system includes pressure censors, AD board, LED monitor, and the computer with real-time graphics. Both gas production and DM digestibility data were fitted into the exponential equation P = a + b (1-e-$1-e^{-ct}$). The initial rate of gas production was highest for rice straw, followed by barley straw and wheat straw. The gas production rate of constant (c) in gas production for rice straw, wheat straw, and barley straw were 3.8, 2.5, and 2.5 $%h^{-1}$, respectively. Total VFA concentration (mM) produced after 72h incubation was similar among three Korean straws, even though was variable during the early (12h) fermentation. Volume of gas production was related (P> 0.05: r = 0.76 to 0.83) to DM disappearance and also strongly related (p< 0.05: r = 0.91 to 0.98) to VFA concentration at all incubation times. Linear correlation showed between gas production and DM disappearance and VFA by in vitro will be matched in in vivo digestibility.

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.

Study on the Development and Application of Image Viewer System (Image Viewer System의 개발 및 적용에 관한 고찰)

  • Yang, Oh-Nam;Seo, In-Ki;Hong, Dong-Ki;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The number of patients receiving radiotherapy has increased every year and will keep increasing in the future. Therefore, the technique of radiotherapy is developing from day to day, as a result of it, the quantities of image and data used for radiotherapy are also considerably increasing. Therefore, there have been many difficulties in storing, keeping and managing them. Then, we developed and applied this system for improving complicated work process as well as solving these problems with the collaboration Medical Information Team. Materials and Methods: We exported its image at R & V (Record and Verify: Varis vision, Varian, USA) system and planning system after giving some code to be able to access from management system(RO) for department of radiation oncology to PACS. And, we programmed their information by using necessary information among many information included in DICOM head. Results: All images and data generated by our working environment (Simulation CT, L-gram image and internal body structure, DRR, does distribution )were realized at PACS and it became to be possible for clear image to be printed from any computer in department of radiation oncology. Conclusion: It was inevitable to use film during radiotherapy for patients in the past, however, due to the development of this system, film-less system became to be possible. Therefore, the darkroom space and its management cost in relation to the development process disappeared and it became to be unnecessary for spending tangible and intangible financial expense including human resources, time needed for finding film storing space and film and purchasing separate storing equipment for storing images. Finally, we think this system would be very helpful to handle ail complicated processes for radiotherapy and increasing efficiency of overall working conditions.

  • PDF

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

Implementation of the Digital Current Control System for an Induction Motor Using FPGA (FPGA를 이용한 유도 전동기의 디지털 전류 제어 시스템 구현)

  • Yang, Oh
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.11
    • /
    • pp.21-30
    • /
    • 1998
  • In this paper, a digital current control system using a FPGA(Field Programmable Gate Array) was implemented, and the system was applied to an induction motor widely used as an industrial driving machine. The FPGA designed by VHDL(VHSIC Hardware Description Language) consists of a PWM(Pulse Width Modulation) generation block, a PWM protection block, a speed measuring block, a watch dog timer block, an interrupt control block, a decoder logic block, a wait control block and digital input and output blocks respectively. Dedicated clock inputs on the FPGA were used for high-speed execution, and an up-down counter and a latch block were designed in parallel, in order that the triangle wave could be operated at 40 MHz clock. When triangle wave is compared with many registers respectively, gate delay occurs from excessive fan-outs. To reduce the delay, two triangle wave registers were implemented in parallel. Amplitude and frequency of the triangle wave, and dead time of PWM could be changed by software. This FPGA was synthesized by pASIC 2SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to digital current control system for 3-phase induction motor. The digital current control system of the 3 phase induction motor was configured using the DSP(TMS320C31-40 MHz), FPGA, A/D converter and Hall CT etc., and experimental results showed the effectiveness of the digital current control system.

  • PDF

The Implementation of a PC GUI for a Multimedia Tele-Medical System based on ATM / B-ISDN (ATM/B-ISDN 통신망 기반의 멀티미디어 원격의료 정보시스템을 위한 PC용 GUI 구현)

  • 정연기;김영탁
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.1
    • /
    • pp.45-55
    • /
    • 1998
  • In the tele-medical system, the broadband network for multimedia telecommunication and the multimedia terminal equipment for the remote access of the tele-medical information are essential. Especially, the tele-medical terminal equipment should provide the multimedia GUI environment in order to support the similar medical process by the tele-medical system. In this paper, we present a multimedia GUI (Graphic User Interface) for a Multimedia Tele-Medical System (TeleMedi_GUI) based on ATM/B-ISDN. In the tele-medical system, one workstation is used for the multimedia data server that is supporting multiple client terminals that are connected by the ATM network. The client terminals are based on Multimedia Personal Computers, and provide the remote access environment of the tele-medical database. We also developed the remote access protocols among the clients and the server to access multimedia medical information of the multimedia server. With using the TeleMedi_GUI, the doctors can examine and treat patients efficiently, using image data like X-ray/CT and voice data such as the S-ray diagnosis. The result of this paper can be applied to the following areas: 1) the implementation of the advanced medical service system interconnecting the small-scale health center and general hospitals, 2) the development of a fully computerized medical information system within the hospital.

  • PDF

Variation of Dose due to the Wound Electrode of Ionization Chamber (굴곡이 있는 전리함 집전극에 기인한 선량 변화)

  • Lee, Byung-Koo;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.203-209
    • /
    • 2008
  • Nowadays the risk of radiation is getting more serious, so we must know the exact dose that was irradiated, Because very high radiation dose is used in radiation therapy field. We used the ionization chamber which measure the radiation dose in this study. We tried to know the incorrect result from the distortion of geometric structure of ionization chamber and we studied how to find the distortion of geometric structure of ionization chamber. We used a radio fluoroscopy to find the wound degree of electrode of ionization chamber and a reconstructed 3D CT image to analyze the wound degree of electrode quantitatively. we measured degree of distortion by comparing with absorbed dose of normal electrode and wound electrode. The comparative result is not absolute dosimetry at specific point but relative dosimetry between thats. We measured 4 MV, 10MV photon with same absorbed dose and dose rate. The degree of distortion of wound electrode was totally $5.5{\sim}7.2%$, and there was no difference between two energies. The variation induced from radiation dose to be irradiated and dose rate, and the degree of distortion from wound direction also was almost similar value. We could find that the geometric structure of ionization chamber that can influence a basic measurement of radiation dose can be changed by old usage and inattention of management in this study, especially winding of electrode can be happened, in radiation therapy field, It is very important to keep precise radiation dose quantitatively.

A Study on Perception by Examinees of the Dental Hospital Institutions about Exposure to Radioactivity (치과병원에 내원한 환자의 방사선피폭 인지도에 관한 연구)

  • Yeo, Jin-Dong;Ko, In-ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.233-243
    • /
    • 2018
  • The purpose of this study was to investigate factors of perception by inpatients of the Dental Hospital institutions about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 65.5.0% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 56.1% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 26.3% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.