Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines - (진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 -)

  • Lee, Won-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.206-212
    • /
    • 2014
  • We report here on the results of evaluating the radiation doses using chest computed tomography (CT) for patients with pneumoconiosis complication. For the first time, we visited the 17 MIPs to evaluate the dose-length product (DLP, $mGy{\cdot}cm$), CT unit, and protocols of scanning and image reconstruction those is routinely used for treating patients with pneumoconiosis who have complication. All statistical analysis was performed using the Statistical Program for Social Sciences (SPSS ver. 19.0, Chicago, IL, USA). Mean of total DLP was $727.7mGy{\cdot}cm$, ranging from 272.0 to $1228.7mGy{\cdot}cm$. DLP from obtaining parenchymal lung images was significantly reduced than that from obtaining total lung images (555.9 vs. 707.2, p<0.001). Third quartile of total and pre-scanning DLP was 1036.1 and $504.1mGy{\cdot}cm$, respectively. Chest CT radiation doses for patients with pneumoconiosis complication are similar with korean diagnostic reference level as well as international guidelines.

Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer (병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점)

  • Hyun, Seung-Hyup;Choi, Joon-Young;Lee, Su-Jin;Cho, Young-Seok;Lee, Ji-Young;Cheon, Mi-Ju;Cho, Suk-Kyong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: This study was performed to find the current problems of positron emission tomography/computed tomography(PET/CT) data on CD for inter-hospital transfer. Materials and Methods: The subjects were 746 consecutive $^{18}F$-fluorodeoxyglucose PET/CT data CDs from 56 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data CDs were reviewed and the email questionnaire survey about this was performed. Results: PET/CT data CDs from 21 of 56 hospitals(37.5%) included all transaxial CT and PET images with DICOM standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. According to this survey, the main reason of limited PET/CT data on CD for inter-hospital transfer was that the data volume of PET/CT was too large to upload to the Picture Archiving and Communication System. Conclusion: The majority of hospitals provided limited PET/CT data on CD for inter-hospital transfer, which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data on CD for inter-hospital transfer including all transaxial CT and PET images with DICOM standard format.

High Resolution Computerized Tomography System Using the Microfocus X-Ray for Inspection of Small Specimens (소형 물체의 검사를 위한 고해상도 미세 초점 X선 단층 촬영 시스템)

  • Kim, Young-Joo;Koo, Ja-Yong;Lee, Seung-S.;Kim, Whan-W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.181-190
    • /
    • 1998
  • A computerized tomography system was developed using the X-ray source that has diameter of 5 micrometer. The system is used for the nondestructive testing of specimens with diameter below 20 mm. The convolution back projection algorithm was adopted for the reconstruction of cross sectional image, and the shape of the X-ray beam was let parallel beam or fan beam to compare each resultant image. Our CT system was constructed to operate based on the personal computer. The sectional images of the fabricated specimens were reconstructed and analyzed. The reconstructed images well coincided with real images taken with optical microscope and gave us enough reports on the defects in the ceramic specimen. The resolution of the system regarded as about $20{\sim}30$ micrometers.

  • PDF

A Study on Stereo Visualization of the X-ray Scanned Image Based on Volume Reconstruction (볼륨기반 X-선 스캔영상의 3차원 형상화 연구)

  • Lee, Nam-Ho;Park, Soon-Yong;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1583-1590
    • /
    • 2011
  • As the existing radiation scanning systems use 2-dimensional radiation scanned images, the low accuracy has been pointed out as a problem of it. This research analyzes the applicability of the stereo image processing technique to X-ray scanned images. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. As the radiation image is just a density information of the scanned object, the direct application of the general stereo image processing techniques to it is inefficient. To overcome this limitation of a stereo image processing in radiation area, we reconstruct 3-D shapes of the edges of the objects. Also, we proposed a new volume based 3D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment.

Use of Cross Pins and Temporal External Skeletal Fixator for Stabilization of a Tibial Physeal Fracture in a Korean Native Calf (한우 송아지의 정강뼈 성장판 골절에서의 교차핀과 임시 외부 골격 고정장치의 이용)

  • Heo, Su-Young;Kim, Eun-Ju;Kim, Min-Su;Lee, Ki-Chang;Kim, Nam-Soo;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2012
  • A one-month-old, male Hanwoo calf was presented to Chonbuk Animal Medical Center with non-weight bearing lameness on its right hindlimb. The radiograph and CT scan showed a Salter-Harris III fracture at the distal tibia. Following open reduction, the fracture was stabilized by cross-pins. A temporal external skeletal fixator was used as an additional support for 5 weeks. 5 weeks after surgery, bone fracture had successfully healed with no complication. At 2 years after surgery, the calf could walk almost normally although intermittent weight-bearing lameness after active exercise. This is a rare case that the combined use of temporal external fixation and cross-pins fixation was sufficiently effective for treating a distal tibial physeal fracture in a calf.

운용관리기능

  • Kim, Hae-Suk;Choe, Go-Bong;Kim, Yeong-Si
    • ETRI Journal
    • /
    • v.8 no.2
    • /
    • pp.109-116
    • /
    • 1986
  • 본고는 TDX-1 전전가 교환기의 운용 관리기능인 과금, 통계, MMC 및 데이터 처리기능과 이들을 보조하는 각종 입출력 장치인 TTY(CRT) terminal, disk unit, CT unit, MT unit 및 data link 제어기능에 대하여 기술하였다.

  • PDF

홍보자료 I: 2011년부터 동물병원 방사선 관리제도가 시행됩니다

  • 대한수의사회
    • Journal of the korean veterinary medical association
    • /
    • v.47 no.3
    • /
    • pp.207-216
    • /
    • 2011
  • 2011년 1월 26일 관련 법규(동물 진단용 방사선발생장치의 안전관리에 관한규칙)가 제정되어 시행됨에 따라 X-ray, CT 등 방사선발생장치를 사용하려는 동물병원은 사용일 3일전까지 시 군 구청에 신고하여야 하며 사용기록을 작성하고 필요한 검사를 받아야 합니다.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

Changes in Volume Dose by Treatment Plan According to pCT and CBCT in Image-guided Radiation Therapy for Prostate Cancer (전립선암 영상유도방사선치료 시 pCT와 CBCT에 따른 치료계획별 체적선량의 변화)

  • Won, Young Jin;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.209-214
    • /
    • 2018
  • The results of CBCT was obtained using image guided radiation therapy for radiation therapy in 5 prostate cancer patients. Using these results, we compared and evaluated the dose changes according to the treatment plan depending on the volume and position of bladder, rectum, and prostate. The 28 images of CBCT were acquired using On-Board Imaging device before radiotherapy. After the outline of bladder, rectum, and PTV, pCT images and CBCT images for radiotherapy were treated respectively. The volume of the bladder was increased by 105.6% and decreased by 45.2%. The volume of the rectum was increased by 30.5% and decreased by 20.3%. Prostate volume was increased by 6.3% and decreased by 12.3%. The mean dose of the rectum was higher in the CBCT than in the pCT, and V40 (equivalent to 40 Gy) of the bladder showed a reduction in all treatment regimens in the CBCT than in the pCT. Conformity treatment and homogeneity index of PTV showed better results in all treatment regimens using pCT than CBCT. It was found that the dose distribution of the pelvic internal organs varied greatly according to the patient 's condition and pretreatment.