• Title/Summary/Keyword: CT모델

Search Result 372, Processing Time 0.025 seconds

A PREDICTION OF BONY INTERFERENCE BETWEEN PROXIMAL & DISTAL SEGMENT OF THE MANDIBLE WITH INTEGRATED 3D SOLID MODEL AND DENTAL CAST IN ORTHOGNATHIC SURGERY (턱교정 수술에서 3차원 입체 모델과 치아 석고모형의 결합을 이용한 하악 근원심 골편간 간섭의 예측)

  • Kwon, Tae-Geon;Lee, Sang-Han;Kim, Jong-Bae;Nam, Ki-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.163-168
    • /
    • 2003
  • Three-dimensional solid model has not been widely used in surgical prediction of orthognathic surgery because frequent artifacts from occlusal restorations or prosthesis limited the usefulness of simulated surgery involving occlusion. We prepared three-dimensional(3D) solid model from CT data and integrated the 3D solid model with dental cast using a face-bow transfer technique combined with skeletal reference measurement and confirmation with cephalometric radiographs. With this simple and easy method, it was possible to predict bony interference between the proximal and distal segment of the mandible so that we can prevent condylar displacement after sagittal split ramus osteotomy of the mandible with prominent asymmetry. The method error was within 2mm and it seemed to be useful in preoperative planning for maxillofacial surgery with maxillo-mandibular occlusal change.

Characteristics of tool wear in cutting of glass fiber reinforced plastics (유리섬유 강화 플라스틱 절삭시의 공구마멸 특성)

  • 강명순;이원평
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1055-1062
    • /
    • 1988
  • The characteristics of tool wear and the machinability in cutting of GFRP have been studied. The wear behavior of carbide insert tools(P20, M10, K10) and Cermet in TiC grade was studied by turning of changing the cutting condition. Machinability could be estimated as the following empirical formula, CT$^{n}$ =W The main results obtained are as follows: (1) Dependence of rate of tool wear on cutting speed; with increases of cutting speed, the rate of tool wear initially increases gradually(1st range), then it increases proportionally to cutting speed(2nd range), and finally the rate is constant(3rd range). (2) When the contact length has a main, effect on tool wear, the cutting speed does nit affect the tool wear. On the contrary, the cutting speed has a main effect on tool wear, the contact length does not affect the tool wear. (3) The order of machinability is K10, M10, P20 and Cermet in TiC grade.

A Physical Ear Model for Evaluating Hybrid-acoustic Sensor Characteristics of Fully Implantable Middle-ear Hearing Aid (완전 이식형 인공중이의 하이브리드 음향센서 특성 평가를 위한 귀 물리모델)

  • Shin, Dong Ho;Moon, Ha Jun;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.8
    • /
    • pp.923-929
    • /
    • 2019
  • In this paper, biomimetic based physical ear model proposed for measuring the characteristics of a hybrid-acoustic sensor for fully implantable middle-ear hearing aid. The proposed physical ear model consists of the external ear, middle-ear, and cochlea. The physical ear model was implemented based on the anatomical structure and CT images of the human ear. To confirm the characteristics of the ear model, the vibrational characteristics of the stapes was measured after applying sound pressure to the tympanic membrane. The measured results were compared with the vibrational characteristics of the human temporal bone specified by ASTM F2504-05. Through the comparison results, the feasibility of the proposed ear model was confirmed. Then, after attaching the hybrid-acoustic sensor to the ear model, the output characteristics of the ECM and acceleration sensor were measured according to the sound pressure. The measured results were compared with previous studies using human temporal bone, and the usefulness of the proposed physical ear model was verified through the analysis results.

Effects of Hansu-Daebowon (HDW) on RANKL-induced Osteoclast Differentiation and Bone Loss in Mammal Model (한수대보원이 포유동물인 생쥐 모델에서 골 손실 및 RANKL 유도 파골세포 분화에 미치는 영향)

  • Jang, Si-sung;Ryu, Hong-sun;Jeon, Chan-yong;Hwang, Gwi-seo
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.1
    • /
    • pp.58-69
    • /
    • 2019
  • Objective: This study investigated the effects of Hansu-Daebowon (HDW) on bone resorption in vitro and bone loss in vivo. Methods: Osteoclast differentiation was measured by counting TRAP (+) MNC formed from RAW 264.7 in the presence of RANKL. Bone pit formation was determined in an artificial bone slice loaded with RANKL-stimulated osteoclasts. To elucidate the mechanisms of the inhibitory effects of HDW on bone resorption and osteoclast differentiation, osteoclastogenic genes (i.e. TRAP, MMP-9, NFATc1, c-Fos, and Cathepsin K) were measured using real time PCR. Furthermore, bone loss was observed using micro-CT in an LPS-treated mammal model. Results: HDW inhibited the bone pit formation in vitro and inhibited bone loss in vivo. Moreover, HDW decreased the number of TRAP (+) MNCs in the presence of RANKL, and HDW inhibited the expressions of cathepsin K, MMP-9, TRAP, NFATc1, and c-Fos in the osteoclasts. Conclusion: HDW exerts inhibitory effects on bone loss and bone resorption resulting from the inhibitions of osteoclast differentiation and osteoclastogenic gene expression.

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

PET-CT study of satisfaction with health services inspector (PET-CT 검사자의 의료서비스 만족도에 관한 연구)

  • Kang, Su-Man;Kim, Kap-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.207-215
    • /
    • 2011
  • This study was focused to the effects of cancer patient's perceived quality of medical service upon satisfaction as a customer who have been stressed to face the death. we established research model between medical service quality and customer satisfaction, and build up 4 hypotheses between tangibility, expertise, credibility, responsiveness and customer satisfaction. 220 responses were used to analyzed with multiple regression analysis by SPSS for Windows 14.0K. All 4 hypotheses were accepted. Among 4 independent variables tangibility was most effective to customer satisfaction as coefficient-0.298, and next expertise was as coefficient 0.237. From the results we suggested the implications as follows; first, the medical institute have to develop medical service based on tangibility, expertise, credibility, responsiveness. Second, such services might bring higher customer satisfaction. Third, the patient satisfaction may lead to extend its own life. Fourth, the hospital also may survive long against the competitive environment with such services.

A Study of License acquisition Method Supporting Mutual Compatibility of EPUB-based eBook DRM (EPUB 기반 전자책 DRM의 상호호환성을 지원하는 라이선스 발급 방법에 관한 연구)

  • Kim, Tae-Hyun;Kang, Ho-Gap;Kim, Yoon-Ho;Cho, Seong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.205-214
    • /
    • 2013
  • The study of the compatibility of EPUB DRM, granted by the Korea Copyright Commission, as a CT R & D project (Project Title: Development of standard reference software technology for the International Standard EPUB-based eBook DRM) developed standards such as profile standards for encryption, digital signature and authentication certificates and standards for technical terms of rights information. In 2012, these four standards have been established as the Korean Industrial Standards under the names of 'Encryption specification for EPUB DRM', 'the Digital signature specification for EPUB DRM', 'the Certificate specification for EPUB DRM', and 'Definitions of Right Terms for EPUB DRM' through the ODPF(Open Digital Standardization Forum) and the TTA(Telecommunications Technology Association). In spite of the establishment of the eBook DRM standards, however, the absence of the standard technology which supports the compatibility for issues and changes of licenses makes it unable to use eBooks served by different eBook distributors. This study tries to investigate technological approaches to methods of license issues supporting eBook DRM compatibility on the basis of the above-mentioned four EPUB DRM standards and to provide an industrially accepted technological model.

The Effect of Silk Fibroin/Nano-hydroxyapatite/Corn Starch Composite Porous Scaffold on Bone Regeneration in the Rabbit Calvarial Defect Model (가토 두개골 결손 모델에서 실크단백과 나노하이드록시아파타이트, 옥수수 녹말 복합물을 이용한 골 이식재 개발)

  • Park, Yong-Tae;Kwon, Kwang-Jun;Park, Young-Wook;Kim, Seong-Gon;Kim, Chan-Woo;Jo, You-Young;Kweon, Hae-Yong;Kang, Seok-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.6
    • /
    • pp.459-466
    • /
    • 2011
  • Purpose: This study evaluated the capability of bone formation with silk fibroin/nano-hydroxyapatite/corn starch composite scaffold as a bone defect replacement matrix when grafted in a calvarial bone defect of rabbits $in$ $vivo$. Methods: Ten New Zealand white rabbits were used for this study and bilateral round-shaped defects were formed in the parietal bone (diameter: 8.0 mm). The silk fibroin 10% nano-hydroxyapatite/30% corn starch/60% composite scaffold was grafted into the right parietal bone (experimental group). The left side (control group) was grafted with a nano-hydroxyapatite (30%)/corn starch (70%) scaffold. The animals were sacrificed at 4 weeks and 8 weeks. A micro-computerized tomography (${\mu}CT$) of each specimen was taken. Subsequently, the specimens were decalcified and stained with Masson's trichrome for histological and histomorphometric analysis. Results: The average ${\mu}CT$ and histomorphometric measures of bone formation were higher in the control group than in the experimental group at 4 weeks and 8 weeks after surgery though not statistically significant ($P$ >0.05). Conclusion: The rabbit calvarial defect was not successfully repaired by silk fibroin/nano-hydroxyapatite/corn starch composite scaffold and may have been due to an inflammatory reaction caused by silk powder. In the future, the development of composite bone graft material based on various components should be performed with caution.

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.