• Title/Summary/Keyword: CR 분석

Search Result 1,481, Processing Time 0.029 seconds

Analysis of the hazardous RoHS materials in polyethylene and polypropylene samples by bench-top and portable XRF methods (탁상형 및 휴대형 X-선 형광 분석기를 이용한 폴리에틸렌 및 폴리프로필렌 시료 중 RoHS 규제 물질의 비교 분석)

  • Choi, Soo-Jung;Kim, Chong-Hyeak;Lee, Sueg-Geun;Kang, In-Sung
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.74-82
    • /
    • 2010
  • As a basic research for development of the domestic portable XRF spectrometer, we discussed the analytical results of bench-top and portable XRF methods for RoHS materials of the Cd, Pb, Hg, Cr(IV), polybrominated biphenyls(PBB) and polybrominated diphenyl ehters(PBDE). The instrumental parameters such as measurement time of bench-top and portable XRF were optimized using certified reference materials of polyethylene and polypropylene with 5 hazardous materials of 0~1,200 mg/kg. The quantitative analysis of total-Cr, total-Br, Cd, Hg and Pb in certified reference materials and plastic samples were compared by empirical method, fundamental parameter method of bench-top XRF and portable XRF.

Water Quality and Particle Size Distributions of Road Runoff in Storm Event (강우시 도로유출수 수질특성 및 입경분포)

  • Lee, Jun-Ho;Cho, Yong-Jin;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.777-784
    • /
    • 2005
  • The first flush phenomenon is defined as the initial period of road runoff during which the concentration of pollutants was significantly high. Road runoff contains significant loads of micro-particles, heavy metals and organic constituents. There were two major objectives of this study. The first objective was to characterize the road runoff. The second objective was to measure and evaluate particle sire distribution of the road runoff, Stormwater runoff was monitored on two sites of four lane road areas along with traffic volume. A total six storm events were monitored to characterize the road runoff. The quantity of road runoff and quality constituents, including chemical oxygen demand ($COD_{Cr}$), suspended solids(SS), total Kjeldahl nitrogen (TKN), ortho-phosphorus ($PO_4-P$), total phosphorus(TP), heavy metals and particle size distribution were analyzed. The results indicate that the concentration of SS, $COD_{Cr}$, TKN and TP ranges were $45{\sim}2,396\;mg/L$, $40{\sim}931\;mg/L$, $0.1{\sim}19.6\;mg/L$, and $0.2{\sim}25.1\;mg/L$, respectively. The results of the regression analysis between SS and the others constituents shows that $COD_{Cr}$, TP, Cu, Pb were highly correlated. And the results showed that the mean range of particle size and uniformity coefficient for road runoff were $6.7{\sim}23.4{\mu}$ and $6.4{\sim}10.2$, respectively.

Deposition Properties of NiCr Thin Films Prepared by Thermal Evaporation (Thermal Evaporation법으로 제조한 NiCr 박막의 증착 특성)

  • Kun, Yong;Park, Yong-Ju;Choi, Seoung-Pyung;Jung, Jin;Choi, Gwang-Pyo;Ryu, Hyun-Wook;Park, Jin-Seong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.6
    • /
    • pp.450-455
    • /
    • 2004
  • NiCr thin films were fabricated by thermal evaporation method using NiCr alloy as evaporating source. NiCr thin films were annealed at various temperatures in air atmosphere in order to investigate effects of annealing conditions on phase change, composition, and microstructures of NiCr films. Typical multilayer was formed after annealing in air atmosphere. This results from the diffusion and oxidation of Cr toward surface during annealing. In the case of annealing at 700$^{\circ}C$, large columnar grains of NiO were formed on Cr-oxide layer through the diffusion and oxidation of Ni over Cr-oxide layer. Especially, NiO layer was formed additionally on surface, sustaining the underlayer structure with the formation of porous Ni layer.

Performance Evaluation of a Cooperative Spectrum Sensing using the k-out-of-n Fusion Rule in CR Networks (CR 네트워크에서 k-out-of-n 융합 규칙을 사용한 협력 스펙트럼 감지 방식의 성능 분석)

  • Lee, Sang-Wook;Lim, Chang-Heon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.5A
    • /
    • pp.429-435
    • /
    • 2009
  • Cooperative spectrum sensing allows secondary users of a cognitive radio(CR) network to collaborate to determine whether a primary user occupies the spectrum of interest or not. It usually performs spectrum sensing by combining the individual decisions of each second user into a final one and the k-out-of-n fusion rule is a general approach for decision fusion. This rule declares that the spectrum is occupied only when the decisions from more than k-1 secondary users indicate the presence of a primary user. In this paper, we analyze a cooperative spectrum sensing scheme with the fusion rule under the constraint that its detection probability is maintained to be no less than a given level and its numerical results for the case of a CR network with 10 secondary users.

Spectroscopic and Thermal Studies of [Cr2(NH2)2(H2O)2(SO4)2]·2H2O,[Cr(NCO)3(H2O)]·3H2O and [Fe O(OH)]·0.2H2O Compounds Formed by the Reactions of Urea with Cr2(SO4)3, Cr(CH3COO)3 AND Fe2(SO4)3

  • Sadeek, S.A.;Refat, M.S.;Teleb, S.M.
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.4
    • /
    • pp.358-366
    • /
    • 2004
  • The bridged disulphato complex $[Cr_2(NH_2)_2(H_2O)_2(SO_4)_2]{\cdot}2H_2O$, terminal triisocyanato $[Cr(NCO)_3(H_2O)]{\cdot}3H_2O$ complex and limonite, $[FeO(OH)]{\cdot}0.2H_2O$ compound were prepared by the reaction of $Cr_2(SO_4)_3{\cdot}xH_2O, Cr(CH_3COO)_3$ and $Fe_2(SO_4)_3$, respectively, with urea in aqueous media at $80^{\circ}C$. The infrared spectra of the products indicate that the absence of the bands of urea, but shows the characteristic bands of coordinated amide, water, bridged sulphato and isocyanato groups. Thermogravimetric (TG) and differential thermal analysis (DTA) measurements on the complexes are also recorded. The data obtained agree quite well with the expected structures. A general mechanisms describing the formation and its thermal decomposition of the complexes are suggested.

The Study of Hyperfine Fields for Co0.9Zn0.1Cr1.9857Fe0.02O4 (Co0.9Zn0.1Cr1.9857Fe0.02O4 물질의 초미세자기장 연구)

  • Choi, Kang-Ryong;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.1
    • /
    • pp.39-42
    • /
    • 2008
  • [ $AB_2X_4$ ](A, B=Transition Metal, X=O, S, Se) are cubic spinel normal ferrimagnets, in which M ions occupy the tetrahedral sites and Cr ions occupy the octahedral sites. Recently, they have been investigated for behaviour of B site ions and A-B interaction. Polycrystalline $[Co_{0.9}Zn_{0.1}]_A[Cr_{1.98}{^{57}Fe_{0.02}}]_BO_4$ compound was prepared by wet-chemical process. The ferrimagnetic transition was observed around 90K. $M\"{o}ssbauer$ absorption spectra at 4.2K show that the well-developed two sextets are superposed with small difference in hyperfine fields($H_{hf}$). The hyperfine fields of $CoCr_{1.98}{^{57}Fe_{0.02}}O_4$ and $Co_{0.9}Zn_{0.1}Cr_{1.98}{^{57}Fe_{0.02}}O_4$ were determined to be 488, 478 kOe and 486, 468 kOe, respectively. We notice that the one of the magnetic hyperfine field values changes with Zn ion substitution. These results suggest the incommensurate states and spin-reorientation temperature($T_S=18K$) changes with Zn ions substitution below spin-reorientation temperature($T_S=28K$) of $CoCr_{1.98}{^{57}Fe_{0.02}}O_4$

Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions (400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정)

  • Kim, Sunghwan;Nam, Uk-Won;Lee, Jaejin;Park, Won-Kee;Pyo, Jeonghyun;Moon, Bong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • In this study, equivalent dose and LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) were performed using 400 MeV/u C heavy ions in HIMAC (Heavy Ion Medical Accelerator in Chiba) for high LET radiation therapy. The irradiated CR-39 SSNDTs were etched according the etching condition of JAXA (Japan Aerospace Exploration Agency). And the etched SSNTDs were analyzed by using Image J. Determined frequency mean dose (${\bar{y_D}}$)and dose-mean lineal energy (${\bar{y_F}}$)of 400 MeV/u C are about 8.5keV/mm and 10.1 keV/mm, respectively by using the CR-39 SSNTD. This value is very similar to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC (Tissue Equivalent Proportional Counter) active radiation detector. We could determine the equivalent dose and LET calibration factors of CR-39. And we confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry in hadron radiotherapy.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.

The Analysis of the UV cut-off effect of tinted lens and the Characteristic of UV tester (착색렌즈의 UV 차단효과와 UV TESTER 평가 분석)

  • Park, Moon Chan;Jung, Boo Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.129-134
    • /
    • 2002
  • We obtained the UV cut-off effect of tinted CR-39 Ophthalmic lens with the respect of concentration of green, brown, blue color. First, we analyzed the UV spectrum of tinted CR-39 lens measured by Spectrophotometer and then compared the UV data by Spectrophotometer with UV data by UV tester used in an optician shop. The result obtained show that the UV cut-off effect is increased with color concentration of tinted CR-39 lens, and the transmittance of 0%~5% at 400nm by Spectrophotometer is correspondence with transmittance of 0% by UV tester.

  • PDF

Synthesis characterization of Ni-Cr nanofibers via electrospinning method (전기방사를 통한 Ni-Cr 나노 섬유 합성 및 특성분석)

  • Lee, Jeong-Hun;Won, Mi-So;Lee, Gyu-Hwan;Choe, Seung-Mok
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.168.2-168.2
    • /
    • 2017
  • 발열체는 전기 에너지를 열 에너지로 변환시키는 전기 저항체인데, Ni-Cr계 합금이 발열 가능 온도가 범위가 크고 열 효율 및 내 산화성, 내 부식성이 우수하여 발열체로 많이 사용되고 있다. 그리고 기존의 선형 발열체의 효율성을 개선한 면상 발열체가 개발되었고, 최근 나노 기술의 발달로 나노크기의 ITO(Indium Tin Oxide) 입자나 탄소나노튜브가 코팅된 형태의 투명 면상 발열체가 개발되어 주목을 받고 있다. 투명 면상 발열체는 발열체의 형태를 거시적으로 확인할 수 없기 때문에 자동차의 전면 유리 히터 및 건축용 기능성 창호 등의 심미적 효과를 요구하는 제품에 사용될 수 있다. 본 연구에서는 PVP(Poly vinyl Pirrolidone)을 이용하여 Ni-Cr Nanofiber 제조를 위한 효율적인 전기 방사 조건을 도출한다. PVP 질량에 따라서 Ethanol과 Methanol, 물을 이용하여 viscosity와 ion conduciviy를 조절하였고, 전기방사 조건으로 bead를 최소화 하는 나노섬유를 얻었다. 이어서 Ni-Cr/PVP 용액은 Metal Precursor wt.% 조절 및 방사조건으로 100~300nm의 직경을 가진 나노 섬유를 얻을 수 있었다. 산화/환원 열처리 후 PVP와 Oxide가 제거된 Ni-Cr nanofiber를 합성하였다. Nanofiber 형상은 FE-SEM으로 측정하였으며, XRD, FT-IR 분석을 통해 제작된 나노 섬유의 구조적 특성을 확인하였다.

  • PDF