• Title/Summary/Keyword: CPT

Search Result 509, Processing Time 0.032 seconds

단순 Matrix LCD 기술

  • 이응상;박호영
    • 전기의세계
    • /
    • v.38 no.10
    • /
    • pp.45-51
    • /
    • 1989
  • 현대 사회가 정보화 사회로 변천해 감에 따라 정보처리 장치를 많이 사용하게 되었으며 기계와 인간을 연결하는 매체가 필요하게 되었다. 이러한 매체중의 하나로 부각되어진 것이 영상정보표시장치이며 현재는 다종의 DISPLAY가 사용되고 있다. 이러한 DISPLAY중에서도 현재까지 가장 많이 이용되고 있는 DISPLAY DEVICE는 CRT와 CPT가 있지만 소비전력이 많고 무거우며 부피가 크다는 단점을 가지고 있기 때문에 보다 새로운 DISPLAY DEVICE가 요구되게 되었다.

  • PDF

New design for SuperSlim CPT

  • Tenner., M.G.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.119-121
    • /
    • 2003
  • A working prototype of a 32-inch wide-screen CRT is presented with a tube length of only 32 cm. This small length requires a '$135^{\circ}$' deflection design, which puts strong requirements upon the DY, glass and mask box design.

  • PDF

미국, 수용가의 자주적 참여에 의한 PG&E 사의 지구온난화 대책 추진

  • Korea Electric Association
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.367
    • /
    • pp.62-63
    • /
    • 2007
  • 미국 캘리포니아 주의 전력회사 퍼시픽 가스 & 일렉트릭 (PG&E)사는 2007년 봄부터 "Climate Smart" 라고 하는 지구온난화대책 프로그램을 추진하기 시작하였다. 이것은 PG&E 사가 제공하는 기후보호요금(Climate Protection Tariff : CPT)을 통하여 수용가 스스로 전기사용량에 따른 할증금을 지불하여, 전기 사용으로 인하여 발생하는 지구 온난화 가스의 배출이 상쇄(Climate neutral) 될 수 있도록 하는 미국에서 처음으로 추진되는 자주적 프로그램이다.

  • PDF

A Study on the Difference of Responses to the Visual or Auditory Stimulus in Sasang Constitution Groups (사상인(四象人)의 시각(視覺) 및 청각(聽覺) 자극에 대한 반응 차이 연구)

  • Shin, Dong-Yoon;Kim, Young-Won;Song, Jeong-Mo;Yoo, Kyung;Park, Hyeon-Chol;Kim, Lak-Hyeong
    • Journal of Sasang Constitutional Medicine
    • /
    • v.17 no.3
    • /
    • pp.76-81
    • /
    • 2005
  • 1. Objectives The purpose of this study is to find the difference of response to visual or auditory stimulus in Sasang Constitutional groups. 2. Methods Continuous performance test (CPT)-ADS program- was measured in 44 females in 20's. The mean and standard deviation of response time were measured and analysed statically in each group of Sasang Constitution. 3. Results There were significant results in the average of response time. The average of the response time to the auditory stimulus in Soyangin was shorter then that of in Soeumin 4. Conclusions The results suggest that there could be differences in the pattern of response to circumstantial stimulus in Sasang Constitution.

  • PDF

An Interference Isolation Method for Wireless Power and Signal Parallel Transmissions on CPT Systems

  • Zhou, Wei;Su, Yu-Gang;Xie, Shi-Yun;Chen, Long;Dai, Xin;Zhao, Yu-Ming
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.305-313
    • /
    • 2017
  • A novel interference isolation method is proposed by using several designed coils in capacitive power transfer systems as isolation impedances. For each designed coil, its stray parameters such as the inter-turn capacitance, coil resistance and capacitance between the coil and the core, etc. are taken into account. An equivalent circuit model of the designed coil is established. According to this equivalent circuit, the impedance characteristic of the coil is calculated. In addition, the maximum impedance point and the corresponding excitation frequency of the coil are obtained. Based on this analysis, six designed coils are adopted to isolate the interference from power delivery. The proposed method is verified through experiments with a power carrier frequency of 1MHz and a data carrier frequency of 8.7MHz. The power and data are transferred parrallelly with a data carrier attenuation lower than -5dB and a power attenuation on the sensing resistor higher than -45dB.

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Yoo, Dong-Ju;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF

Sliding Mode Control of a Cargo System Model Using ER Valve-Actuators (ER 밸브 작동기를 이용한 하역시스템 모델의 슬라이딩모드 제어)

  • Choe, Seung-Bok;Kim, Hyeong-Seok;Jeong, Dal-Do;Seong, Geum-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.1982-1992
    • /
    • 1999
  • This paper presents a novel concept of cargo handling system adapted for a sea port subjected to severe time-varying tide. The proposed system can perform loading or unloading by using a sort of hydraulic elevator associated with real-time position control. In order to achieve a proof-of-concept, a small-sized laboratory model of the cargo handling system is designed and built. The model consists of three principal components container palette transfer (CPT) car, platform with lifting columns, and cargo ship. The platform activated by electro-rheological (ER) valve-cylinders is actively controlled to track the position of the cargo ship subjected to be varied due to the time-varying tide and wave motion. Following the derivation of the dynamic model for the platform and cargo ship motions, an appropriate control scheme is formulated and implemented. The location of the CPT car is sensed by a set of photoelectric switches and controlled via sequence controller. On the other hand, a sliding mode controller (SMC) is adopted as the position controller for the platform. Both simulated and measured control results are presented to demonstrate the effectiveness of the proposed cargo system.

Binding Mode and Inhibitory Activity of Constituents Isolated from Sclerotium of Poria cocos with DNA Topoisomerase I (Poria cocos 균핵에서 분리한 성분들과 DNA Topoisomerase I의 반응양상 및 효소저해 활성)

  • Choi, Inhee;Kim, Ji-Hyun;Kim, Choonmi
    • YAKHAK HOEJI
    • /
    • v.49 no.5
    • /
    • pp.428-436
    • /
    • 2005
  • DNA topoisomerase I(TOP1) helps the control of DNA replication, transcription and recombination by assist­ing breaking and rejoining of DNA double strand. Camptothecin (CPT) and its derivative, topotecan, are known to inhibit TOP1 by intercalating into TOP1-DNA complex. Recently various non-CPT intercalators are synthesized for a new class of TOP1 inhibitors. In this study, six compounds isolated from Poria cocos were investigated for their interaction with TOP1­DNA complex using the flexible docking program, FlexiDock. The binding modes were analyzed and compared with the TOP1 inhibition activities. The compounds that showed potent activity were intercalated between the + 1/-1 base pairs of DNA, located near the active site phosphotyrosine723 and formed hydrogen bonds with active site residues. On the other hand, compounds with no activity were not docked at all. The binding modes were well correlated with the inhibition activity, suggesting the possibility that potent inhibitors can be designed from the information presented by the docking study.