• Title/Summary/Keyword: CPM

Search Result 428, Processing Time 0.026 seconds

Quantifying Monetary Value of Float

  • Park, Young-Jun;Lee, Dong-Eun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.111-113
    • /
    • 2015
  • Floats are used by the parties involved in a construction project. The owner may use float by changing order(s) or by executing risk avoidance plan; the contractor may use it for leveling resources or substituting activities' construction methods to reduce costs. Floats are accepted either just as by-product obtained by critical path method(CPM) scheduling or as asset having significant value. Succinctly, existing studies involved in float value does not consider its' changes on project time domain. It is important to identify float ownership and to quantify its' corresponding values. This paper presents a method that quantifies float value of money that changes over project execution. The method which accurately computes the monetary value of float may contributes to resolve conflicts relative to float ownership and/or delay issues among project participants. It compares the difference between the monetary value of total float - on non-critical path in each and every schedule update. It makes use of critical path method (CPM) and commercial software with which practitioners are already familiar.

  • PDF

Staffing-Technology Fit in Construction Scheduling

  • Yang, Juneseok;Arditi, David
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.631-635
    • /
    • 2015
  • Construction managers use scheduling methods to improve the outcome of their project. In spite of the many obvious advantages of the critical path method (CPM), its use in construction has been limited. Understanding the reasons why CPM is not used as extensively as expected could improve its level of acceptance in the construction industry. The link between construction scheduling methods and the capabilities of the scheduling staff has been an on-going concern in the construction industry. This study proposes a staffing-technology fit model to understand why CPM is not used as extensively as expected in construction scheduling. A staffing-technology fit model that aims to measure the extent to which a construction scheduling method matches the staff's experience, know-how and capabilities. The model that is proposed is an answer to the lack of proper instruments for evaluating the extent to which scheduling methods are used in the industry.

  • PDF

Interactions between Water-Soluble Polyparacyclophanes and Drugs (III) -Complex Formation of Water-Soluble Polyparacyclophanes with Fluorescent Hydrophobic Naphthalene Derivatives in Aqueous Solution- (수용성 폴리파라시클로판류와 약물과의 상호작용(제 3보)-수용액 중 수용성 폴리파라시클로판류와 형광 소수 나프탈렌 유도체류와의 복합체 형성-)

  • Chun, In-Koo;Lee, Min-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.19 no.2
    • /
    • pp.71-79
    • /
    • 1989
  • Complex formation of water-soluble polyparacyclophanes bearing two diphenylmethane or two diphenyl ether skeletons with l-anilinonaphthalene-8-sulfonate (ANS) and 2-p-toluidinylnaphthalene-6-sulfonate (TNS) was investigated quantitatively to develop useful host compounds comparing with ${\alpha}\;-\;and\;{\beta}-cyc1odextrins$$({\alpha}-\;and\;{\beta}-CyDs$) in aqueous solution. Benesi-Hildebrand type analysis of the fluorescent intensity showed that the dissociation constants (Kd) of paracyclophane-ANS complexes were $1.55\;{\times}\;10^{-4}M$ for 1,6,20,25-tetraaza[6.1.6.1]paracyclophane(CPM 44) and $1.23\;{\times}\;10^{-4}M$ for 1,7,21,27-tetraaza[7.1.7.1]paracyclophane (CPM 55), and those of paracyclophane-TNS complexes were $6.99\;{\times}\;10^{-6}M$ for CPM 44 and $6.23\;{\times}\;10^{-5}M$ for CPM 55, in 1:1 molar ratio. On the other hand, the Kd values of 1,7,21,27-tetraaza-14,34-dioxa[7.1.7.1]paracyclophane (CPE 55)-ANS, 1,8,22,29-tetraaza-15,36-dioxa[8.1.8.1]paracyclophane (CPE 66)-ANS, CPE 55-TNS, CPE 66-TNS complexes were $1.75\;{\times}\;10^{-3}M$, $3.07\;{\times}\;10^{-3}M$, $3.75\;{\times}\;10^{-3}M$ and $2.15\;{\times}\;10^{-3}M$, respectively. On the contrary, the Kd values of ${\alpha}-CyD-ANS$, ${\beta}-CyD-ANS$, ${\alpha}-CyD-TNS$ and ${\beta}-CyD-TNS$ complexes were found to be $3.98\;{\times}\;10^{-2}M$, $1.05\;{\times}\;10^{-2}M$, $1.38\;{\times}\;10^{-2}M$ and $3.52\;{\times}\;10^{-4}M$, respectively. These results mean that the complexation of CPMs with ANS or TNS is by 5.6-1,975 fold stronger than that for ${\alpha}-or\;{\beta}-CyDs$, and the complex formation of CPEs with ANS or TNS is nearly same as or somewhat stronger than that for ${\alpha}-or\;{\beta}-CyDs$. From the Kd values determined at different temperatures, thermodynamic parameters were calculated and the complexation was found to be a spontaneous exothermic reaction. The effects of pH on Kd values of CPM 44-ANS, and CPM 55-ANS complexes were negligible in the range of pH 1.2-1.8. However, the Kd values of these complexes increased significantly with increasing ionic strength.

  • PDF

Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships (선박배출 배기냉각과 흡수식이 결합된 하이브리드 시스템을 통한 물 회수 및 미세먼지 저감을 위한 기초실험연구)

  • Youngmin Kim;Donggil Shin;Younghyun Ryu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1252-1258
    • /
    • 2022
  • The exhaust gas from the marine engines include a quantity of water vapor and particulate matter. The total particulate matter includes filterable particulate matter (FPM) and condensable particulate matter (CPM) that condense after releasing into the atmosphere. The portion of CPM is higher than that of FPM that is removable through the filter before discharging. An experimental setup for waste heat and water recovery and removal of CPM in the exhaust gas was tested using an industrial gas boiler in the laboratory. The water and CPM in the exhaust gas were removed through the first stage of cooling method and further removed through the second stage of absorption method. The efficiencies of water recovery were 73% after the first stage of cooling method and 90% after the second stage of absorption method. At the same time, the CPM was removed by 80-90% through the processes. The waste heat recovered could be used to process heat, and the water recovered could be used to process water in the ship. Furthermore, the CPM, which is a major source of the particulate matter but not subject to administrative regulation, could be removed effectively.

Case Report: Quantitative Evaluation of Gait Function Following Treatment Progression in a Patient with Central Pontine Myelinolysis (중심성 교뇌수초용해 환자의 치료 경과에 따른 보행 기능의 정량적 평가)

  • Sangho Ji;Sunny Kang;Jiwoo Kim;Youngjo So;Sangkwan Lee;Cheol-Hyun Kim
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.190-198
    • /
    • 2024
  • Introduction: Central pontine myelinolysis (CPM) is a rare neurological disorder marked by symmetric nerve fiber damage, commonly following rapid hyponatremia correction, with no established treatment and a poor prognosis. The condition, often linked to alcoholism, malnutrition, and various diseases, lacks comprehensive studies on its impact on gait. This research aims to quantitatively analyze gait changes in CPM patients receiving both traditional Korean and conventional rehabilitation treatments, addressing a gap in current understanding of CPM management. Case presentation: A 56-year-old male diagnosed with CPM following an initial misdiagnosis underwent combined electoracupuncture and rehabilitative treatment at ○○ university Korean medical center, resulting in significant gait improvements. A treadmill gait analysis system was used to measure changes in key gait parameters at 2-week intervals, and the patient's progress was documented. Conclusions: The quantitative analysis revealed significant gait improvements. Foot rotation decreased from 8.9° to 6.4° (right) and from 11.1° to 7.2° (left); lateral symmetry improved from -7.8 to 0.8; step length increased from 21 cm to 44 cm (right) and from 19 cm to 44 cm (left); and velocity increased from 1.2 m/s to 2.7 m/s. These findings highlight decreased foot rotation and lateral symmetry, along with increased step length and velocity, suggesting a positive outcome of the treatment regimen. Notably, the patient experienced no adverse effects related to the treatments. Despite limitations, including the singe case focus and lack of prior gait-focused CPM research, this case report provides valuable insights into effective CPM management strategies, paving the way for future research in this domain.

A CPM-type Magnetic Levitation System Design (CPM형 자기부상 시스템의 설계)

  • Kim, Jong-Moon;Kang, Do-Hyun;Woo, Byung-Chul;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.155-157
    • /
    • 2003
  • In this paper, CPM(controlled-permanent magnet)-type magnetic levitation system design is presented. The target plant to be controlled consists of eight magnets with permanent magnet and electromagnet. The design procedure is also described and the result of this work is shown.

  • PDF

Vibration Control of A CPM Maglev System (CPM형 자기부상의 진동제어)

  • Kim Jong-Moon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1001-1003
    • /
    • 2004
  • In this paper, the vibration control of CPM(Controlled-Permanent Magnet) type magnetic levitation system of 1ton is designed and implemented. The target to be controlled has 8 magnets and 4 corners of the maglev module are levitated using a digital feedback controller. The designed controller includes PID type gap controller and speed observer. Its performance is validated by some kinds of experiments.

  • PDF

Control of 1-ton CPM Maglev System (1톤급 영구자석형 자기부상 시스템 제어)

  • Kim Jong-Moon;Woo Byung-Chul;Kang Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.998-1000
    • /
    • 2004
  • In this paper, the control system of the controlled-permanent magnet(CPM) type MagLev system of 1ton is designed and implemented. The target to be controlled is PEM(permanent and electromagnet) type with 4-corners levitation which is open-loop unstable, highly non-linear and time-varing system. The designed controller is validated by some kinds of experiments.

  • PDF