• 제목/요약/키워드: CPF

검색결과 100건 처리시간 0.027초

SSSC 투입에 따른 연계선로의 송전운용한계 개선 (Enhancement of Interface Flow Limit using Static Synchronous Series Compensator(SSSC))

  • 김슬기;송화창;이병준;권세혁;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.28-30
    • /
    • 2000
  • This paper introduces a power flow model of SSSC for voltage stability study. The SSSC model is obtained from the injection model of voltage source inverter by adding the condition that SSSC injection voltage is in quadrature with current of SSSC-installed branch. This model is incorporated into modified CPF algorithm to study effects of SSSC on the security-constrained interface flow limit. Determination of interface flow limit is simply briefed. In case study a 771-bus real system is used to show that SSSC can improve interface flow limit in terms of voltage stability.

  • PDF

전력조류계산을 위한 SSSC모델의 개발과 연속조류계산 알고리듬에의 적용 (Development of SSSC Power Flow Model and its Implementation into Continuation Power Flow Algorithm)

  • 김슬기;송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1158-1160
    • /
    • 1999
  • This paper proposes a SSSC(Static Synchronous Series Compensator) power flow model to be incorporated into power flow calculation for the steady state analysis of the power system. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. In this paper the static model is implemented into the continuation power-flow (CPF) program. It is shown that SSSC has its intrinsic superiority over TCSC in controllable power flow range.

  • PDF

전력계통의 TTC(Total Transfer Capability) 산정을 위한 수송능력평가 프로그램 향상 (Enhancement Power System Transfer Capability Program (PSTCP) To Calculate Total Transfer Capability in Power Systems)

  • 김상암;이병준;송길영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1514-1516
    • /
    • 1999
  • This paper presents a sequential framework that calculates the total transfer capabilities of power transmission systems. The proposed algorithm enhances the Power System Transfer Capability Program (PSTCP) in conjunction with the Continuation Power Flow(CPF) that is used for steady-state voltage stability analysis and modified Arnoldi-Chebyshev method that calculates rightmost eigenvalues for small signal stability analysis. The proposed algorithm is applied to IEEE 39-bus test system to calculate TTC.

  • PDF

전압안정도를 고려한 미소신호안정도 해석 (Analysis of Small Signal Stability Considering Voltage Stability)

  • 김동준;문영환;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.323-326
    • /
    • 2001
  • This paper describes the algorithm which can not only take account of voltage suability but also consider small signal stability. As for voltage stability both CPF and PoC methods are utilized to pinpoint the exact voltage collapse point. Then, using the converged load flow results full system matrix is configured and its eigenvalues are computed. The suggested algorithm is applied to the Two-area system, and verified its usefulness. In addition this paper also deals with the results of analyzing the two-area system in terms of voltage stability and small signal stability.

  • PDF

토피가 큰 콘크리트 지하구조물의 기둥에 대한 시간의존적 해석 (Time dependent Analysis of RC Column in Subway Structure having high Filled Soil Layer)

  • 정제평;이상희;김생빈;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.603-608
    • /
    • 1998
  • This study was performed to examine the effect of time dependent properties on RC columns in subway structures subjected to high filled soil layer. By using Program TCC which is a modified version of CPF for the present purpose, a typical column in subway structure was analyzed. Four different model equations for predicted time dependent concrete properties(ACI, CEB-FIP, Bazant & Panula and Korea Bridge Specification) was employed, and the results were compared. It was found that a relevant creep coefficient is recommended to be 1.0 for designing columns in subway structure, and the sol filling work would be performed at least 3 months later after the concrete casting in order to ensure durability by reducing the negative effect of concrete time dependent properties.

  • PDF

Compliant Press-Fit Pin 결합에서 발생하는 음력분포특성에 대한 유한요소해석 (Finite Element Analysis of the Stress Distribution Characteristics in the Compliant Press-Fit Pin Connection)

  • 김병탁
    • 한국해양공학회지
    • /
    • 제14권4호
    • /
    • pp.79-85
    • /
    • 2000
  • Press-fit pin connection is the solderless interference-fit between pins and plated through holes(PTH) in the printed curcuit board(PCB). Because of not only its simple assembly and absence of problems associated with soldering, but also its good mechanical and electrical characteristics, the press-fit pin connection technology has quickly gained wide acceptance in the telecommunications and computer industries. In this paper, the contact stress characteristics of the domestic CPF pin when inserted into the friction coefficients were compared and the stress variations of the compliant part of the pin, which have an influence on the performance, were displayed with the time and arc length after complete connected. It is supposed that the results will provide useful data to improve the performance of the pin-PCB interconnection mechanism.

이차함수 근사화를 이용한 가용송전용량 산정에 관한 연구 (Calculation of ATC using Quadratic Function Approximation in Bulk Power System)

  • 신상헌;신동준;이효상;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.673-675
    • /
    • 2003
  • As the electrical power industry is restructured and the electrical power exchange is updated per hour, it is important to accurately and rapidly quantify ATC of the transmission system. This paper proposed QFA method, which can reduce calculation time comparing with CPF method and has few errors in ATC calculation. It proved that the method can calculate ATC more fast and accurately in case study using IEEE 24 bus RTS(MRTS) and 7 bus.

  • PDF

확률론적 조류계산을 이용한 송전 신뢰도 여유 계산 (Calculate Transmission Reliability Margin using Probabilistic Load Flow)

  • 신동준;김진오;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2003
  • As a definition of NERC, Available Transfer Capability(ATC) is a measure of the transfer capability remaining in the physical transmission network for the future commercial activity. To calculate ATC, accurate and defensible TTC, CBM and TRM should be calculated in advance. In this paper, we propose a method to quantify TRM using probabilistic load flow based on the method of moment. Generation output, bus voltages, loads, and line outages are considered as complex random variables (CRV) to take into account for uncertainties related to the transmission network conditions. Probability Density Function (PDF) of line flow at the most limiting line is used to quantify TRM with the desired probabilistic margin. Suggested method is compared with the results from conventional CPF method and verified using 24 bus MRTS, and the suggested method based on PLF shows efficiency and flexibility for the quantification of TRM compared with the conventional method.

  • PDF

Optimization of Heat Exchanger Network in the Steam Assisted Gravity Drainage Process Integration

  • Rho, Seon-Gyun;Yuhang, Zhang;Hwang, InJu;Kang, Choon-Hyoung
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.260-269
    • /
    • 2020
  • The Steam Assisted Gravity Drainage (SAGD) process is an enhanced method to extract oil from bitumen which involves surface and central process facilities. This paper describes the Central Process Facilities (CPF) of SAGD and proposes several retrofit plans to the Heat Exchanger Network (HEN). In this approach, the process integration scheme is applied to estimate the energy saving in HENs, and various cases are modeled in favor of a commercial simulator. Throughout this work, a minimum approach temperature of 10℃ is assumed. The results reveal that, due to the HEN optimization using process integration, the heating and cooling duties can be reduced to 29.68MW and 1.886MW, respectively. Compared with the Husky case, all cases considered in this study indicate a potential reduction of at least 6% in total cost, including investment and operation costs.

전력 산업 구조 개편 상황에서 적정 송전 용량 여유도 산정 (Calculation of TRM and CBM for Electricity Market Restructuring)

  • 신상헌;신동준;김진오;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.429-431
    • /
    • 2003
  • Available Transfer Capability(ATC) calculation is a complicated task, which involves the determination of TTC, TRM, and CBM. This paper proposed QFA method, which can reduce the calculation time comparing with CPF method and has few errors in ATC calculation. It proved that the method can calculate ATC more fast and accurately in the case study using IEEE 24 bus RTS(MRTS).

  • PDF