• Title/Summary/Keyword: CPE

Search Result 267, Processing Time 0.025 seconds

The Critical Point Equation on 3-dimensional α-cosymplectic Manifolds

  • Blaga, Adara M.;Dey, Chiranjib
    • Kyungpook Mathematical Journal
    • /
    • v.60 no.1
    • /
    • pp.177-183
    • /
    • 2020
  • The object of the present paper is to study the critical point equation (CPE) on 3-dimensional α-cosymplectic manifolds. We prove that if a 3-dimensional connected α-cosymplectic manifold satisfies the Miao-Tam critical point equation, then the manifold is of constant sectional curvature -α2, provided Dλ ≠ (ξλ)ξ. We also give several interesting corollaries of the main result.

SOME PROPERTIES OF CRITICAL POINT EQUATIONS METRICS ON THE STATISTICAL MANIFOLDS

  • Hajar Ghahremani-Gol;Mohammad Amin Sedghi
    • Communications of the Korean Mathematical Society
    • /
    • v.39 no.2
    • /
    • pp.471-478
    • /
    • 2024
  • The aim of this paper is to investigate some properties of the critical points equations on the statistical manifolds. We obtain some geometric equations on the statistical manifolds which admit critical point equations. We give a relation only between potential function and difference tensor for a CPE metric on the statistical manifolds to be Einstein.

Serological Classification of Porcine Enteroviruses Isolated in Korea (국내(國內)에서 분리(分離)된 Porcine Enterovirus의 혈청학적(血淸學的) 분류(分類))

  • Shin, Tae-kyun;Lee, Cha-soo;Kwon, Hyock-jin;Knowles, Nick J.
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.223-226
    • /
    • 1987
  • Serological classification was carried out on 10 samples of PEV isolated from the feces, the milk and the brain of the diseased pigs in Korea by CFT using type specific antisera of PEV. Ten samples of PEV were classified into 2 serotypes which were serotype 3 and 8. PEV from the feces belonged to serotype 8 and those from the milk and the brain to serotype 3. The cross reaction of serotype 3 occurred especially with serotype 1. Talfan virus. It can be said that at least 2 serotypes of PEV have existed in Korea.

  • PDF

A Study on the EM Wave Absorption Characteristics of Amorphous Metal Powder and Sendust Absorbers for RFID System (RFID 시스템용 Amorphous Metal Powder 및 Sendust 흡수체의 전파흡수 특성 연구)

  • Choi, Dong-Soo;Yoo, Gun-Suk;Choi, Dong-Han;Kim, Dong-Il
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.159-160
    • /
    • 2010
  • In this paper, we compared the absorption abilities of AMP and Sendust EM wave absorbers for a port logistics RFID system. Firstly, we fabricated EM wave absorber samples by using each absorbing material, AMP or Sendust, and CPE (Chlorinated Polyethylene) with composition ratios 85 : 15 wt. %. Secondly, we designed the optimum EM wave absorber using the calculated material constants found from the measured input impedance of the samples. Therefore, we confirmed that imaginary factor of complex relative permeability influences absorption ability and that AMP is better absorbing material than Sendust at the frequency band of 433 MHz.

  • PDF

Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry (네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출)

  • Boo, Han-Kil;Song, Youn-Joo;Park, Se-Jin;Chung, Taek-Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • Electrochemical behavior of fluoroquinolone antibacterial agents on carbon paste electrode (CPE) were investigated by cyclic voltammetry and square wave adsorptive stripping voltammetry. The fluoroquinolone antibacterial agents tested in this study were Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL) and Levofloxacin (LEV). In acetate buffer at pH 4.5, the oxidation peak potentials of the fluoroquinolone antibacterial agents of ENR, NOR, CIP, OFL, and LEV were 0.952 V, 1.052 V, 1.055 V, 0.983 V, and 0.990 V (vs. Ag/AgCl), respectively. And their oxidation peak currents from square wave adsorptive stripping voltammograms are proportional to the concentration of each antibacterial agent over the range from $0.2\;{\mu}M$ to $1\;{\mu}M$.

Papillomatosis on the skin of the wild marbled sole Pleuronectes yokohamae (자연산 문치가자미, Pleuronectes yokohamae 피부의 육아종)

  • Park, Jung-Jun;Byoun, Ju-Young;Choi, Hye-Sung;Park, Myoung-Ae;Kwon, Mun-Gyeong;Kim, Seok-Ryel
    • Journal of fish pathology
    • /
    • v.24 no.3
    • /
    • pp.213-223
    • /
    • 2011
  • Among wild marbled sole, Pleuronectes yokohamae caught in west coastal area, Chungnam, tumor-bearing fish were found. Parasites and pathogenic bacteria were not detected and CPE was not observed. Using the light microscope, the epidermal layer of wild P. yokohamae was significantly thickened compared to the normal skin. The lesion was formed papillary folds. Hypertropical epithelial cells revealed karyolysis, marked nucleolus and cloud swelled cytoplasm. In the epidermal layer of the lesion, X-cell that is characterized by oval and small pale nucleus and prominent nucleolus was observed. Dermal layer had newly formed vessels. The size of mucous cell in the papilloma lesion was significantly increased compared to the normal. In this study, no pathogens were found, so future works for finding cause of the papilloma in the P. yokohamae are needed.

A Study on Development of Electro Magnetic Wave Absorbers for Mobile Phones (휴대전화 단말기용 전파 흡수체의 개발에 관한 연구)

  • Choi Yun-Seok;Jung Jae-Hyun;Kim Dong-Il
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.423-429
    • /
    • 2006
  • This paper deals with research for development of electromagnetic wave absorbers in sheet type for mobile phones. By controlling the sendust ratio, the $Al(OH)_3$ coating, the thickness, the kind of binders, and the milling time, electromagnetic wave absorbers were prepared and examined. Central frequency shills toward lower 2.2 GHz, 1.29 GHz, 842 MHz with increasing thickness 1 mm, 2 mm, 3 mm of the absorber, and absorption ability controlled each 2.2 GHz to 1.91 GHz, 1.29 GHz to 801 MHz, 842 MH2 to 801 MHz adjust sendust amount from 80 wt% to 85 wt%. The absorption band of the electromagnetic wave absorber coated with $Al(OH)_3$ becomes larger than that of non-coated one. Sendust composite microwave absorbers mixed with CPE were prepared at $70^{\circ}C$ in temperature. The fabricated electromagnetic wave absorbers show a reflection coefficient 5.76 dB at 1.8 GHz in thickness of 0.85 mm.

Comparison of specific activity and cytopathic effects of purified 33 kDa serine proteinase from Acanthamoeba strains with different degree of virulence

  • Kim, Won-Tae;Kong, Hyun-Hee;Ha, Young-Ran;Hong, Yeon-Chul;Jeong, Hae-Jin;Yu, Hak-Sun;Chung, Dong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.4 s.140
    • /
    • pp.321-330
    • /
    • 2006
  • The pathogenic mechanism of granulomatous amebic encephalitis (GAE) and amebic keratitis (AK) by Acanthamoeba has yet to be clarified. Pretense has been recognized to play an important role in the pathogenesis of GAE and AK. In the present study, we have compared specific activity and cytopathic effects (CPE) of purified 33 kDa serine proteinases from Acanthamoeba strains with different degree of virulence (A. healyi OC-3A, A. lugdunensis KA/E2, and A. castelianii Neff). Trophozoites of the 3 strains revealed different degrees of CPE on human corneal epithelial (HCE) cells. The effect was remarkably reduced by adding phenylmethylsulfonylfluoride (PMSF), a serine proteinase inhibitor. This result indicated that PMSF-susceptible proteinase is the main component causing cytopathy to HCE cells by Acanthamoeba. The purified 33 kDa serine proteinase showed strong activity toward HCE cells and extracellular matrix proteins. The purified proteinase from OC-3A, the most virulent strain, demonstrated the highest enzyme activity compared to KA/E2, an ocular isolate, and Neff, a soil isolate. Polyclonal antibodies against the purified 33 kDa serine proteinase inhibit almost completely the proteolytic activity of culture supernatant of Acanthamoeba. In line with these results, the 33 kDa serine proteinase is suggested to play an important role in pathogenesis and to be the main component of virulence factor of Acanthamoeba.

Using the SIEM Software vulnerability detection model proposed (SIEM을 이용한 소프트웨어 취약점 탐지 모델 제안)

  • Jeon, In-seok;Han, Keun-hee;Kim, Dong-won;Choi, Jin-yung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.4
    • /
    • pp.961-974
    • /
    • 2015
  • With the advancement of SIEM from ESM, it allows deep correlated analysis using huge amount of data. By collecting software's vulnerabilities from assessment with certain classification measures (e.g., CWE), it can improve detection rate effectively, and respond to software's vulnerabilities by analyzing big data. In the phase of monitoring and vulnerability diagnosis Process, it not only detects predefined threats, but also vulnerabilities of software in each resources could promptly be applied by sharing CCE, CPE, CVE and CVSS information. This abstract proposes a model for effective detection and response of software vulnerabilities and describes effective outcomes of the model application.

Determination of Ag(Ⅰ) Ion with a Chemically Modified Carbon Paste Electrode Containing Cinchonidine (Cinchonidine으로 변성된 Carbon Paste 전극을 사용한 은이온의 정량)

  • Kim, Sin Hui;Won, Mi Suk;Sim, Yun Bo
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.734-740
    • /
    • 1994
  • Electrochemical determination of Ag(I) ion was carried out by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the carbon paste electrode (CPE) containing cinchonidine. The detection limit for Ag(I) ion was shown to be $1.0 {\times}10^{-6}$ M in conventional CV and up to $8.0{\times}10^{-9}$ M (${\pm}$0.6%) using DPV. The optimum analytical condition of Ag(I) ion was determined as follows: pH 7, 20 minutes of deposition time, and 50% (w/w) cinchonidine to carbon powder composition of electrode. The interference effect of various metal ions added to the deposition solution was also studied. The peak current of Ag(I) ion except Hg(II) ion was decreased roughly 25% compare to Ag(I) ion only. When Mn(II) ion was present in sample solution at pH 9, shown a large interference effect.

  • PDF