• Title/Summary/Keyword: CONDITION FACTOR

Search Result 4,490, Processing Time 0.039 seconds

Characteristics of Fault Current Division Factor & Groud Potential Rise of a Substation fed exclusively by Power Cables (지중케이블 변전소의 고장전류 분류율과 접지전위상승 특성)

  • Choi, Jong-Kee;Jung, Gil-Jo;Kim, Seon-Gu
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.295-297
    • /
    • 1998
  • This paper shows characteristics of fault current division factor $S_f$, which is a ratio of earth- return current to total fault current, at a substation fed exclusively by power cables under unsymmetrical fault condition, such as single line-to-ground fault. In substation grounding system design, $S_f$ is a very important factor determining GPR, touch and step voltage at a substation under fault condition. In case of substations fed by overhead lines, 40-60% of $S_f$ has been typically used, although it is a very conservative value with no other network conditions considered. It is authors' hope that $S_f$ presented in this paper could hopefully be a basic reference in designing of substation grounding system, especially for a substation fed exclusively by power cables.

  • PDF

The Relationship between Stress and Leisure Satisfaction of College Student Athletes (대학 운동부 학생들의 스트레스와 여가만족과의 관계)

  • Chon, Tae-Jun
    • Journal of Wellness
    • /
    • v.6 no.2
    • /
    • pp.139-147
    • /
    • 2011
  • The purpose of this study was to examine the relationship between stress and leisure satisfaction of college student athletes. The participants comprised 140 of the college student athletes. The measures were composed of stress inventory and leisure satisfaction scale. The data were analyzed by SPSS 17.0 Version frequency analysis, reliability analysis, confirmatory factor analysis, independent sample t-test, one-way ANOVA, and multiple regression analysis were performed. The level of significance was set up .05. The results were as follows: First, according to college, there was significant difference in economic burden, environmental condition, and course factor. Second, in regard with multiple regression analysis on relationships between the stress and leisure satisfaction of the college student athletes, discriminative evaluation, environmental condition, and course factor had positive effect on leisure satisfaction.

A Study on the Correlation between the index Values and Qualitative·Quantitative Evaluation Elements and the Distinction Ability of the Journals' Registration Condition of the KCI-based Composite index in Evaluating Korean Journals (한국 학술지 평가를 위한 KCI 기반 복합지표의 지수 값과 질적·양적 평가요소 사이의 연관성 및 학술지 등재 상태 구별 능력에 관한 연구)

  • Ko, Young-Man;Park, Ji-Young
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.46 no.2
    • /
    • pp.245-260
    • /
    • 2012
  • This study aims to analyze the change in the correlation between the index values and qualitative quantitative evaluation elements by applying 'the decile of total number of articles' instead of the average annual number of articles in Kor-Factor2, and to evaluate the distinction ability between registered journals and register nominee journals of the KCI. The correlation between the index values and qualitative quantitative evaluation elements was analyzed by calculating the correlation coefficient between the index values and the evaluation elements, and then the correlation was compared with that of Kor-Factor2. To evaluate the distinction ability, we carried out independent samples t-test on the mean difference between index values of register nominee journal group and registered journal group and compared the mean difference with that of Kor-Factor2, IF and journal h-index. As a result, we found that the modified index applying the decile of total number of articles was effective in improving the balance among the correlation between the index values and qualitative quantitative evaluation elements compared to Kor-Factor2, and the new index appeared to be superior to other indexes on distinction ability of the journal's registration condition in the KCI.

Effects of Preparatory Movements on Performance of Sideward Responsive Propulsion Movement (사전동작이 좌우 반응 추진운동의 수행력에 미치는 영향)

  • Kim, Yong-Woon;Yoon, Te-Jin;Seo, Jung-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.9-19
    • /
    • 2005
  • The purpose of this study was to analyze the effects of three different types of preparatory movement(squat, countermovement and hopping) in sideward responsive propulsion movement. 7 healthy subjects performed left and right side movement task by external output signal. 3D kinematics were analyzed The results were followed First, performance time in the countermovement and hopping conditions was shorter(10-20%) than that in the squat condition. The hopping condition that is more related to pre-stretch showed excellent performance. Second, time difference between after turned on the external signal and until take off was the primary factor in performance results among movement conditions. The preparatory phase before the propulsive phase in the squat condition produced more time than that in other conditions. The hopping condition showed the most short time in both the preparatory and the propulsive phase, therefore it was advantage for performance result Third, significant difference was not found in take-off velocity among movement conditions although there was difference of the time required in the propulsive phase. The maximum acceleration in the propulsive phase was larger in order of the hopping. countermovement, and squat condition. The countermovement and hopping conditions showed high take-off velocity although the propulsive phase in those conditions was shorter than that in squat condition. The pre-stretch by preparatory countermovement was considered as the positive factor of producing power in concentric contraction. Fourth, the hopping condition produced large angular velocity of joints. In hopping condition, large amount of moment for rotation movement was revealed in relatively short time and it was considered to cause powerful joint movements. In conclusion, the hopping movement using countermovement is advantage of responsive propulsion movement. It is resulted from short duration until take off and large amount of joint moment and joint power in concentric contraction by pre-stretch.

Reproductive Ecology of the Freshwater Marsh Clam, Corbicula papyracea (Heude) in Bukhan River (북한강 엷은재첩, Corbicula papyracea (Heude) 의 번식생태)

  • Kim, Dae-Hee;Lee, Wan-Ok;Lee, Jun-Sang
    • The Korean Journal of Malacology
    • /
    • v.30 no.2
    • /
    • pp.107-116
    • /
    • 2014
  • Gonadal development and maturation mechanism were studied on the freshwater marsh clam Corbicula papyracea (Heude), which is the endangered species in Korea. The specimens were collected in the rearing ponds and waterway of NFRDI in Gapyeong-gun, Gyeonggi-do from January to December 2004, and then investigated by condition factor, relative growth, gonadal development phases and gonad histological characters based on 30-50 individuals every month. Comparing with the freshwater marsh clam, C. papyracea is small, light olive brown shell and violet interior. The hermaphrodite individuals of C. papyracea take an internal fertilization and fertilized eggs are stored in the foster-sack in the gills, then the hatched juveniles are released outside after an ovoviviparous process. The average water temperature of inhabit area was in range of $1.8-27.0^{\circ}C$ and usually took great effects on the gonad maturation of C. papyracea. The condition factor ranged from 0.14 to 0.21 throughout the year, which was the lowest during winter season (December-February), and gradually increased to the highest value of 0.21 in May. The ratio of meat weight to total weight was 25.9-38.7%, indicating the similar trend with condition factor. The highest values of condition factor and the ratio of meat weight appeared 1-2 months later than gonadosomatic index reached the peak value, it was probably because that the ovoviviparous eggs would spend a long period before hatching from the foster-sack in the gills. To synthesize the characters of meat weight, condition factor and gonad development by histological study, reproductive cycle of C. papyracea could be divided into five successive stages: multiplicative stage (December to February), growing stage (February to May), mature stage (June to August), spawning stage (August to November), recovery stage (November to December). The smallest shell length of matured C. papyracea was 12.6 mm, and individuals, larger than 16 mm, was formed the nursery in the gills.

Ecological diagnosis of the Gongjicheon water system using length-weight relationship and condition factor(K) of population of the Zacco platypus (피라미 개체군의 length-weight relationship 및 condition factor(K)를 이용한 공지천수계의 생태적 진단)

  • Lee, Kwang-Yeol;Jang, Hara;Yun, Youngjin;Park, Seungchul;Kim, Joon Chul;Lee, Jaeyong;Choi, Jaeseok
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.2
    • /
    • pp.137-149
    • /
    • 2014
  • The purpose of this study is to investigate the dynamics of the Zacco platypus population among streams in the Gongjicheon water system, Korea from December 2010 to October 2011. In this study, fish fauna was collected 27 Species belonged to 9 Families. The legal protection species, such as a natural monument and endangered species was not collected. Korean endemic species was collected 6 species including to Z. koreanus. The ratio of Korean endemic species was 22.6%, and it was lower than 51.3% that average of Korean endemic species in the Hangang water system. About these status, we considered that Gongjicheon water system had lost of the unique characteristics of the Hangang water system by the anthropogenic disturbances. The result of analysis to length-weight relationship and condition factor(K) of Z. platypus population in the Gongjicheon water system, the regression coefficient value(b) to indication of growth degree of the population was 3.04 and the slope of the condition factor(K) to indication of corpulency had positive value, respectively. These results seems to be that the Z. platypus population is maintained to a little unstably. In addition, the values of the degree of growth and corpulence were very low than the other natural streams in the Hangang water system, so it considered that the many artificially stress factors are occurred in this study area. These results are similar to Fish Assessment Index(FAI) in the assessment for health of aquatic ecosystem. Therefore, we are considered to require precise investigation and sustained monitoring for the restorations of stream ecosystem in the Gongjicheon water system.

A Study of Concrete with Large Quantity of Fly-Ash (플라이애쉬 다량 함유 콘크리트에 관한 실험적 연구)

  • 이동하;공민호;백민수;김성식;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1219-1224
    • /
    • 2001
  • In this study, concrete what plenty of fly ash used as binder is left in three condition humid condition($35^{\circ}C$), normal condition($20^{\circ}C$) and cold condition($5^{\circ}C$). Fly ash concrete is tested in fresh properties and early strength. The result of tests could give the decisive factor of form side's stripping time. The purpose of this study is presenting the stripping time data to help the construction work. The result of this study is below. 1. The plain concrete specimen in humid condition developed high strength before 5 days, then strength development is declined. 10 day strength of plain specimen is smaller than the normal condition specimen's. 2. The strength of the concrete which plenty of fly ash used is more developed than the concrete in normal condition. It says that fly ash concrete is useful in the humid condition. 3. As fly ash substitution rate is downsizing and outdoor temperature degree is low, form stripping times is getting shorter.

  • PDF

Factor Analysis of the Relation Between Land Cover Ratio of Green Spaces and Temperature (공원녹지의 토지피복비율과 기온간의 요인분석)

  • Yoon, Yong-Han;Park, Bong-Ju;Kim, Won-Tae;Park, Sun-Young
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.485-491
    • /
    • 2008
  • The present study examined the relation between land cover condition and temperature in various types of urban green spaces. The diagram of temperature distribution showed that high-temperature zones are formed around paved areas, and low temperature zone around planted areas and grassy areas. Even in planted areas where low-temperature zones were formed, temperature was different according to hierarchical structure. That is, temperature was relatively low in areas covered with arbor + sub-arbor. With regard to land cover ratio, the increase of planted areas and grassy areas had an effect on the fall of temperature and the effect was higher in order of planted areas and grassy areas. On the contrary, paved areas and bare areas had an effect on the rise of temperature. According to the results of factor analysis, in case of the highest temperature, planted area and grassy area were put together into a factor lowering temperature, paved area and temperature into a factor raising temperature, and bare area alone into a factor of low significance. In case of the lowest temperature, grassy area and bare area were put together into a factor, and the validity of the factor analysis was proved by the analysis of urban heat islands. An increase in the number of trees by height was effective in lowering temperature, and the effect was high in order to arbor and sub-arbor, and the source of coldness in planted area was tall trees.

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

The Influence of Muddy Water in Imha Reservoir on the Ichthyofauna and Fish Growth (임하호의 탁수가 어류상 및 어류생장에 미치는 영향)

  • Han, Seung-Cheol;Lee, Hak-Young;Seo, Eul-Won;Shim, Jae-Hun;Lee, Jong-Eun
    • Journal of Life Science
    • /
    • v.17 no.8 s.88
    • /
    • pp.1104-1110
    • /
    • 2007
  • The number of investigated fish collected from the Andong and the Imha reservoir were 2,540 individuals 20 species belonging to 7 families, 850 individuals 11 species belonging to 4 families respectively from May 2005 to March 2006. The total number of the common 3 species individuals investigated caught from the Andong reservoir and the Imha reservoir were 486 individuals and 124 individuals respectively. The investigated individuals is similar(${\pm}2.5$ mm) to 171 individuals make a comparative study. The Opsariichthys uncirostris, Culter brevicauda, Hemiculter eigenmanni of length-weight relationship were TW = $0.00007TL^{3.0543}$, TW = $0.0000009TL^{3.3654}$, TW = $0.00000^{3.3872}$ in the Andong reservoir and TW = $0.00002TL^{2.8493}$, TW = $0.00001TL^{2.8744}$, TW = $0.000004TL^{3.1082}$ in the Imha reservoir respectively. The Condition factor(K) of the Andong reservoir showed the positive slopes in all three species and to be in a good nutrition condition; where as the condition factor(K) of the Imha reservoir showed the negative slopes in two species except in H. eigenmanni and appeared to be in a little bad nutrition condition. Relative condition factor(Kn) indicating that O. uncirostris and C. brevicauda in Andong reservoir is more rotund than ones of Imha reservoir but H. eigenmanni in the Imha reservoir is more rotund than the ones of the Andong reservoir.