• 제목/요약/키워드: CODE V

검색결과 735건 처리시간 0.026초

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

Seismic collapse probability of eccentrically braced steel frames

  • Qi, Yongsheng;Li, Weiqing;Feng, Ningning
    • Steel and Composite Structures
    • /
    • 제24권1호
    • /
    • pp.37-52
    • /
    • 2017
  • To quantitatively assess the safety against seismic collapse of eccentrically braced steel frame (EBSF) system, 24 typical EBSFs with K-shape and V-shape braces with seismic precautionary intensities 8 and 9 were designed complying with China seismic design code and relative codes to constitute archetype space of this structure system. In the archetype space, the collapse probability of the structural system under maximum considered earthquakes (MCE) was researched. The results show that the structures possess necessary safety against seismic collapse when they respectively encounter the maximum considered earthquakes corresponding to their seismic precautionary levels, and their collapse probabilities increase with increasing seismic precautionary intensities. Moreover, the EBSFs with V-shape braces have smaller collapse probability, thus greater capacity against seismic collapse than those with K-shape braces.

대형 디젤기관에서 매연가스 예측에 관한 연구 (Study on Smoke Prediction in Heavy-duty Diesel Engine)

  • 백두성;이종선
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.865-870
    • /
    • 2008
  • 대형디젤 기관에서 매연배기가스에 대한 배기가스 재순환장치의 영향을 KIVA-3V 전산유체해석코드를 통해서 수치 해석적으로 연구했다. 지배방정식으로 RNG k-$\varepsilon$ 난류 모델을 이용했고, 무화, 벽 침투 그리고 매연 등의 물리적인 현상을 나타내기 위해서 TAB, Wave, Watkins-Park, Nagle-Strickland 모델이 적용되었다.

횡하중을 받는 내부 슬래브-기둥 접합부의 거동 (Behavior of Interior Slab-Column Connections under Lateral Load)

  • 권대홍;최명신;안종문;이광수;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.154-157
    • /
    • 2006
  • An experimental study was conducted to study the behavior of slab-column connections under lateral load. Test variables include gravity shear ratio$(V_g/V_o=0.3,\;0.5)$ and flexural reinforcement ratio of slab(p=0.01, 0.015). Strength and ductility of tested specimens were evaluated in accordance with gravity shear ratios and slab reinforcement ratios. Shear stresses of Code's equation at the critical section were also compared with experimental results.

  • PDF

STUDY ON X-RAYS AND NEUTRONS LEAKED FROM A 45 MeV ELECTRON LINAC FACILITY

  • Sawamura, Sadashi;Kitaichi, Masatoshi;Nojiri, Ichiro;Yamada, Takuma;Kaneko, Junichi;Sawamura, Teruko
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.133-137
    • /
    • 2001
  • Spatial and time distributions of x-rays and neutrons from Hokkaido University 45 MeV electron linac facility were measured and compared with the calculation. In the calculation, x-rays in a Pb-target were evaluated using the EGS-code. The x-rays and the neutrons from the target to the facility building boundary and skyshine process outside the facility building were simulated with the EGS and the MCNP respectively.

  • PDF

Bending behavior of SWCNT reinforced composite plates

  • Chavan, Shivaji G.;Lal, Achchhe
    • Steel and Composite Structures
    • /
    • 제24권5호
    • /
    • pp.537-548
    • /
    • 2017
  • In this paper presents bending characteristic of single wall carbon nanotube reinforced functionally graded composite (SWCNTRC-FG) plates. The finite element implementation of bending analysis of laminated composite plate via well-established higher order shear deformation theory (HSDT). A seven degree of freedom and $C^0$ continuity finite element model using eight noded isoperimetric elements is developed for precise computation of deflection and stresses of SWCNTRC plate subjected to sinusoidal transverse load. The finite element implementation is carried out through a finite element code developed in MATLAB. The results obtained by present approach are compared with the results available in the literatures. The effective material properties of the laminated SWCNTRC plate are used by Mori-Tanaka method. Numerical results have been obtained with different parameters, width-to-thickness ratio (a/h), stress distribution profile along thickness direction, different SWCNTRC-FG plate, boundary condition, through the thickness (z/h) ratio, volume fraction of SWCNT.

Dopant-Activation and Damage-Recovery of Ion-Shower-Doped Poly-Si through $PH_3/H_2$ after Furnace Annealing

  • Kim, Dong-Min;Kim, Dae-Sup;Ro, Jae-Sang;Choi, Kyu-Hwan;Lee, Ki-Yong
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 2004
  • Ion shower doping with a main ion source of $P_2H_x$ using a source gas mixture of $PH_3/H_2$ was conducted on excimer-laser- annealed (ELA) poly-Si. The crystallinity of the as-implanted samples was measured using a UV-transmittance. The measured value of as-implanted damage was found to correlate well with the one calculated through/obtained from TRIM-code simulation. The sheet resistance was found to decrease as the acceleration voltage increased from 1 kV to 15 kV at a doping time of 1 min. However, it increases as the acceleration voltage increases under severe doping conditions. Uncured damage after furnace annealing is responsible for the rise in sheet resistance.

Sub-micron패턴 형성을 위한 축대칭 이온광학계의 성능해석

  • 이종현;장원익;유형준
    • ETRI Journal
    • /
    • 제11권1호
    • /
    • pp.75-88
    • /
    • 1989
  • 액체금속 이온원에서 추출된 이온빔을 웨이퍼 위에 접속하기 위한 이온광학계에 있어서 축대칭 판형 전극의 전위분포를 계산하는 해석적인 방법을 제시하였다. 이 방법은 이온궤적, 수차 및 이온빔 직경등의 광학 특성을 보다 빠르게 계산할 수 있는 computer code의 개발에 이용되었다. 계산된 광학특성은 Burghard의 결과와 잘 일치하였으며, 기존의 Orloff.lens,Kurihara lens의 aperture 직경을 변화시켜 색수차를 줄이면 이온빔의 직경이 20% 정도 감소되었다. 또한 두개의 렌즈로 이루어진 이온광학계에 대한 전산모사를 통하여 일반적으로 collimated mode가 crossovered mode에 비해 작은 빔직경을 가지며, 5KeV, 50keV의 빔에너지에서 각각 Orloff lens/Orloff-reversed lens, Kurihara lens/Orloff-reversed lens로 조합된 경우가 빔직경의 관점에서 유리함을 알 수 있었다.

  • PDF

수치모델을 이용한 pulsed dc bias ICP장치의 플라즈마 특성 해석 (Numerical Modeling of Plasma Characteristics of ICP System with a Pulsed dc Bias)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제43권3호
    • /
    • pp.154-158
    • /
    • 2010
  • Numerical analysis is done to investigate the effects of pulse bias on the plasma processing characteristics like ion doping and ion nitriding by using fluid dynamic code with a 2D axi-symmetric model. For 10 mTorr of Ar plasma, -1 kV of pulse bias was simulated. Maximum sheath thickness was around 20 mm based on the electric potential profile. The peak electron temperature was about 20 eV, but did not affect the averaged plasma characteristics of the whole chamber. Maximum ion current density incident on the substrate was 200 $A/m^2$ at the center, but was decreased down to 1/10th at radius 100 mm, giving poor radial uniformity.

Monte Carlo simulations of chromium target under proton irradiation of 17.9, 22.3 MeV

  • Kara, A.;Yilmaz, A.;Yigit, M.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3158-3163
    • /
    • 2021
  • Chromium material is commonly used for fusion plasma facing applications because of the low neutron activation property. The Monte Carlo method is one of the useful ways to investigate the ion-target interactions. In this study, Chromium target irradiated by protons was investigated using Monte Carlo based simulation tools. In this context, the calculations of radiation damage on Chromium material irradiated with protons at 17.9 and 22.3 MeV energies were carried out using GEANT4 and SRIM codes. Besides, the cross sections for proton interaction with Chromium target were calculated by the TALYS 1.9 code using CTM + FGM, BSFGM, and GSFM level densities. As a result, GEANT4, SRIM and TALYS 1.9 codes provide a suitable tool for the predictions of radiation damage and cross cross section with proton irradiation.