• Title/Summary/Keyword: CODE V

Search Result 735, Processing Time 0.025 seconds

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

Absorbed Dose Analysis in Water for Proton Beam using PTRAN Code System (PTRAN 코드를 이용한 양성자선에 대한 물 흡수선량의 해석)

  • Kim Jin Young;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.140-148
    • /
    • 2004
  • The absorbed dose for proton beam in water was calculated using the PTRAN code system. The proton interactions with water and the description on absorbed dose calculations are discussed, and the file structure and an execution example of the PTRAN codes are described. For 60, 100, 150, 200, and 250 MeV proton beams it is demonstrated that the absorbed dose is determined from the sum of Coulomb interactions and nuclear reactions, and that the Bragg peak feature depends On the energy straggling and multiple scattering. The PTRAN code was useful for studying the fundamental mechanism of the absorbed dose to water for clinical proton beams.

  • PDF

Association of Lower Socioeconomic Status and SARS-CoV-2 Positivity in Los Angeles, California

  • Allan-Blitz, Lao-Tzu;Goldbeck, Cameron;Hertlein, Fred;Turner, Isaac;Klausner, Jeffrey D.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.54 no.3
    • /
    • pp.161-165
    • /
    • 2021
  • Objectives: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spreads heterogeneously, disproportionately impacting poor and minority communities. The relationship between poverty and race is complex, with a diverse set of structural and systemic factors driving higher rates of poverty among minority populations. The factors that specifically contribute to the disproportionate rates of SARS-CoV-2 infection, however, are not clearly understood. Methods: We evaluated SARS-CoV-2 test results from community-based testing sites in Los Angeles, California, between June and December, 2020. We used tester zip code data to link those results with United States Census report data on average annual household income, rates of healthcare coverage, and employment status by zip code. Results: We analyzed 2 141 127 SARS-CoV-2 test results, of which 245 154 (11.4%) were positive. Multivariable modeling showed a higher likelihood of SARS-CoV-2 test positivity among Hispanic communities than among other races. We found an increased risk for SARS-CoV-2 positivity among individuals from zip codes with an average annual household income

A Study on Improving Compression Ratio Using hybrid Coding (혼합 부호화에 의한 압축률 개선에 관한 고찰II)

  • 차인숙;박지환
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.06a
    • /
    • pp.196-199
    • /
    • 2001
  • 국제 전신전화자문위원회인 ITU-T에서는 일반 공중전화망을 이용하는 데이터 통신을 위하여 표준권고안 중 V시리즈의 하나인 V.42bis라는 표준을 제정하여 권고하고 있다. 이 표준은 자동재전송 방식(ARQ)으로 오류를 제어하고 있는 V.42 표준에 새로이 LZW압축기법을 추가한 것으로 모뎀 내에 오류제어와 데이터 압축방식을 함께 채용함으로써 데이터전송에 있어서 신뢰성과 효율성을 제공하도록 한 것이다. 이 논문에서는 V.42bis방식의 압축 효율성에 대하여 고찰하고, 적응형 산술 부호(Arithmetic Code)와 1중 마르코프 산술부호로 각각 혼합 부호화하여 압축률을 향상시키는 기법에 대하여 기술한다.

  • PDF

Separation of Kernel Space and User Space in Zephyr Kernel (Zephyr 커널에서 커널 공간과 사용자 공간의 분리 구현)

  • Kim, Eunyoung;Shin, Dongha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.4
    • /
    • pp.187-194
    • /
    • 2018
  • The operating system for IoT should have a small memory footprint and provide low power state, real-time, multitasking, various network protocols, and security. Although the Zephyr kernel, an operating system for IoT, released by the Linux Foundation in February 2016, has these features but errors generated by the user code can generate fatal problems in the system because the Zephyr kernel adopts a single-space method that both the user code and kernel code execute in the same space. In this research, we propose a space separation method, which separates kernel space and user space, to solve this problem. The space separation that we propose consists of three modifications in Zephyr kernel. The first is the code separation that kernel code and user code execute in each space while using different stacks. The second is the kernel space protection that generates an exception by using the MPU (Memory Protection Unit) when the user code accesses the kernel space. The third is the SVC based system call that executes the system call using the SVC instruction that generates the exception. In this research, we implemented the space separation in Zephyr v1.8.0 and evaluated safety through abnormal execution of the user code. As the result, the kernel was not crashed by the errors generated by the user code and was normally executed.

QR code as speckle pattern for reinforced concrete beams using digital image correlation

  • Krishna, B. Murali;Tezeswi, T.P.;Kumar, P. Rathish;Gopikrishna, K.;Sivakumar, M.V.N.;Shashi, M.
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.1
    • /
    • pp.67-84
    • /
    • 2019
  • Digital Image Correlation technique (DIC) is a non-contact optical method for rapid structural health monitoring of critical infrastructure. An innovative approach to DIC is presented using QR (Quick Response) code based random speckle pattern. Reinforced Cement Concrete (RCC) beams of size $1800mm{\times}150mm{\times}200mm$ are tested in flexure. DIC is used to extract Moment (M) - Curvature (${\kappa}$) relationships using random speckle patterns and QR code based random speckle patterns. The QR code based random speckle pattern is evaluated for 2D DIC measurements and the QR code speckle pattern performs satisfactorily in comparison with random speckle pattern when considered in the context of serving a dual purpose. Characteristics of QR code based random speckle pattern are quantified and its applicability to DIC is explored. The ultimate moment-curvature values computed from the QR code based random speckled pattern are found to be in good agreement with conventional measurements. QR code encrypts the structural information which enables integration with building information modelling (BIM).

Theoretical simulation on evolution of suspended sodium combustion aerosols characteristics in a closed chamber

  • Narayanam, Sujatha Pavan;Kumar, Amit;Pujala, Usha;Subramanian, V.;Srinivas, C.V.;Venkatesan, R.;Athmalingam, S.;Venkatraman, B.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2077-2083
    • /
    • 2022
  • In the unlikely event of core disruptive accident in sodium cooled fast reactors, the reactor containment building would be bottled up with sodium and fission product aerosols. The behavior of these aerosols is crucial to estimate the in-containment source term as a part of nuclear reactor safety analysis. In this work, the evolution of sodium aerosol characteristics (mass concentration and size) is simulated using HAARM-S code. The code is based on the method of moments to solve the integro-differential equation. The code is updated to FORTRAN-77 and run in Microsoft FORTRAN PowerStation 4.0 (on Desktop). The sodium aerosol characteristics simulated by HAARM-S code are compared with the measured values at Aerosol Test Facility. The maximum deviation between measured and simulated mass concentrations is 30% at initial period (up to 60 min) and around 50% in the later period. In addition, the influence of humidity on aerosol size growth for two different aerosol mass concentrations is studied. The measured and simulated growth factors of aerosol size (ratio of saturated size to initial size) are found to be matched at reasonable extent. Since sodium is highly reactive with atmospheric constituents, the aerosol growth factor depends on the hygroscopic growth, chemical transformation and density variations besides coagulation. Further, there is a scope for the improvement of the code to estimate the aerosol dynamics in confined environment.

Verification of Dose Evaluation of Human Phantom using Geant4 Code (Geant4 코드를 사용한 인체팬텀 선량평가 검증)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4 is compatible with the Windows operating system in C++ language use, enabling interface functions that link DICOM or software. It was simulated to address the basic structure of the simulation using Geant4/Gate code and to specifically verify the density composition and lung cancer process in the human phantom. It was visualized using the Gate Graphic System, i.e. openGL, Ray Tracer: Ray Tracing by Geant4 Tracing, and using Geant4/Gate code, lung cancer is modeled in the human phantom area in 3D, 4D to verify the simulation progress. Therefore, as a large number of new functions are added to the Gate Code, it is easy to implement accurate human structure and moving organs.

Image-Based Machine Learning Model for Malware Detection on LLVM IR (LLVM IR 대상 악성코드 탐지를 위한 이미지 기반 머신러닝 모델)

  • Kyung-bin Park;Yo-seob Yoon;Baasantogtokh Duulga;Kang-bin Yim
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.1
    • /
    • pp.31-40
    • /
    • 2024
  • Recently, static analysis-based signature and pattern detection technologies have limitations due to the advanced IT technologies. Moreover, It is a compatibility problem of multiple architectures and an inherent problem of signature and pattern detection. Malicious codes use obfuscation and packing techniques to hide their identity, and they also avoid existing static analysis-based signature and pattern detection techniques such as code rearrangement, register modification, and branching statement addition. In this paper, We propose an LLVM IR image-based automated static analysis of malicious code technology using machine learning to solve the problems mentioned above. Whether binary is obfuscated or packed, it's decompiled into LLVM IR, which is an intermediate representation dedicated to static analysis and optimization. "Therefore, the LLVM IR code is converted into an image before being fed to the CNN-based transfer learning algorithm ResNet50v2 supported by Keras". As a result, we present a model for image-based detection of malicious code.