• Title/Summary/Keyword: COBRA

Search Result 86, Processing Time 0.02 seconds

Design of Vertical Type Probe Tip Using Finite Element Analysis (유한요소해석을 이용한 수직형 프로브 팁의 설계)

  • Oh, Young-Ryun;Kim, Yun-Jae;Nam, Hyun-Suk;Park, Ung-Gi;Lee, Hak-Joo;Kim, Jung-Yub;Park, Jun-Hyub
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.851-856
    • /
    • 2012
  • The design process of a micro-probe tip is very complicated and expensive. To avoid these problems, in this study, we used element (FE) analysis. To simplify design process. A new pre-probe tip (cobra-needle type) made of Ni and Co was designed by FE analysis. Experimental results were compared with those obtained by FE analysis to verify the reliability of the analysis. The contact force and over drive were respectively found to be 12.5 gf(Contact Force) and $100{\mu}m$(Over drive). We propose the new designed probe tip. Material of new designed probe tip is NiCo. Values of Property are 1~2 gf(Contact Force) and $100{\mu}m$(Over drive).

Alu Hypomethylation in Smoke-Exposed Epithelia and Oral Squamous Carcinoma

  • Puttipanyalears, Charoenchai;Subbalekha, Keskanya;Mutirangura, Apiwat;Kitkumthorn, Nakarin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5495-5501
    • /
    • 2013
  • Background: Alu elements are one of the most common repetitive sequences that now constitute more than 10% of the human genome and potential targets for epigenetic alterations. Correspondingly, methylation of these elements can result in a genome-wide event that may have an impact in cancer. However, studies investigating the genome-wide status of Alu methylation in cancer remain limited. Objectives: Oral squamous cell carcinoma (OSCC) presents with high incidence in South-East Asia and thus the aim of this study was to evaluate the Alu methylation status in OSCCs and explore with the possibility of using this information for diagnostic screening. We evaluated Alu methylation status in a) normal oral mucosa compared to OSCC; b) peripheral blood mononuclear cells (PBMCs) of normal controls comparing to oral cancer patients; c) among oral epithelium of normal controls, smokers and oral cancer patients. Materials and Methods: Alu methylation was detected by combined bisulfite restriction analysis (COBRA) at 2 CpG sites. The amplified products were classified into three patterns; hypermethylation ($^mC^mC$), partial methylation ($^uC^mC+^mC^uC$), and hypomethylation ($^uC^uC$). Results: The results demonstrate that the $%^mC^mC$ value is suitable for differentiating normal and cancer in oral tissues (p=0.0002), but is not significantly observe in PBMCs. In addition, a stepwise decrease in this value was observed in the oral epithelium from normal, light smoker, heavy smoker, low stage and high stage OSCC (p=0.0003). Furthermore, receiver operating characteristic (ROC) curve analyses demonstrated the potential of combined $%^mC$ or $%^mC^mC$ values as markers for oral cancer detection with sensitivity and specificity of 86.7% and 56.7%, respectively. Conclusions: Alu hypomethylation is likely to be associated with multistep oral carcinogenesis, and might be developed as a screening tool for oral cancer detection.

A Study on the Object Security in Distributed Computing Environment (분산 컴퓨팅 환경에서 객체 보안에 관한 연구)

  • Song, Gi-Beom;Lee, Jeong-Ki;Park, Chan-Mo;Roh, Jeong-Hee;Lee, Gwang;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.477-480
    • /
    • 2002
  • Transparency of position that provide quick service regardless of physical position to users in distribution computing environment is getting into prominence and is developed in component form that many application softwares take advantage of distributed object technology. Because design object in distribution computing environment and OMG introduces OMA for embody, defined CORBA by standard of distributed object technology on OMA's abstract picture object model. Security service in CORBA platform is very important. Present object security service in distribution computing environment that refer standard of sorority and security models of distribution computing platform in CORBA in this treatise and follow in CORBA security service rules.

  • PDF

The Effect of KOB-Soil as a Soil Amendment on Turfgrass Growth (종합 토양개량재 KOB-Soil이 잔디 생육에 미치는 영향)

  • 이상재
    • Asian Journal of Turfgrass Science
    • /
    • v.17 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • This study was conducted to figure out the effect of KOB Soil on creeping bentgrass‘Cobra’, Kentucky bluegrass (KB)‘Midnight’75% + Perennial ryegrass (PR)‘Palmer III’25%. This experiment was conducted from September 1, 2001 to August 31, 2002 at Hwajoulryong in Jeongsun County, Gwangwon-do. Treatments were Sand 80% + Peatmoss 20%, Sand 80% +KOB-Soil (No. 1) 20%, and Sand 80% +KOB-Soil (No. 2) 20%. Treatments with KOB Soils was superior to control fer the leaf length, number of leaf, turf quality and root length in Creeping bengrass and Kentucky bluegrass + Perennial ryegrass.

Development of a drift-flux model based core thermal-hydraulics code for efficient high-fidelity multiphysics calculation

  • Lee, Jaejin;Facchini, Alberto;Joo, Han Gyu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1487-1503
    • /
    • 2019
  • The methods and performance of a pin-level nuclear reactor core thermal-hydraulics (T/H) code ESCOT employing the drift-flux model are presented. This code aims at providing an accurate yet fast core thermal-hydraulics solution capability to high-fidelity multiphysics core analysis systems targeting massively parallel computing platforms. The four equation drift-flux model is adopted for two-phase calculations, and numerical solutions are obtained by applying the Finite Volume Method (FVM) and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE)-like algorithm in a staggered grid system. Constitutive models involving turbulent mixing, pressure drop, and vapor generation are employed to simulate key phenomena in subchannel-scale analyses. ESCOT is parallelized by a domain decomposition scheme that involves both radial and axial decomposition to enable highly parallelized execution. The ESCOT solutions are validated through the applications to various experiments which include CNEN $4{\times}4$, Weiss et al. two assemblies, PNNL $2{\times}6$, RPI $2{\times}2$ air-water, and PSBT covering single/two-phase and unheated/heated conditions. The parameters of interest for validation include various flow characteristics such as turbulent mixing, spacer grid pressure drop, cross-flow, reverse flow, buoyancy effect, void drift, and bubble generation. For all the validation tests, ESCOT shows good agreements with measured data in the extent comparable to those of other subchannel-scale codes: COBRA-TF, MATRA and/or CUPID. The execution performance is examined with a mini-sized whole core consisting of 89 fuel assemblies and for an OPR1000 core. It turns out that it is about 1.5 times faster than a subchannel code based on the two-fluid three field model and the axial domain decomposition scheme works as well as the radial one yielding a steady-state solution for the OPR1000 core within 30 s with 104 processors.

Aeroelastic testing of a self-supported transmission tower under laboratory simulated tornado-like vortices

  • Ezami, Nima;El Damatty, Ashraf;Hamada, Ahmed;Hangan, Horia
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.199-213
    • /
    • 2022
  • The current study investigates the dynamic effects in the tornado-structure response of an aeroelastic self-supported lattice transmission tower model tested under laboratory simulated tornado-like vortices. The aeroelastic model is designed for a geometric scale of 1:65 and tested under scaled down tornadoes in the Wind Engineering, Energy and Environment (WindEEE) Research Institute. The simulated tornadoes have a similar length scale of 1:65 compared to the full-scale. An extensive experimental parametric study is conducted by offsetting the stationary tornado center with respect to the aeroelastic model. Such aeroelastic testing of a transmission tower under laboratory tornadoes is not reported in the literature. A multiaxial load cell is mounted underneath the base plate to measure the base shear forces and overturning moments applied to the model in three perpendicular directions. A three-axis accelerometer is mounted at the level of the second cross-arm to measure response accelerations to evaluate the natural frequencies through a free-vibration test. Radial, tangential, and axial velocity components of the tornado wind field are measured using cobra probes. Sensitivity analyses are conducted to assess the variation of the structural dynamic response associated with the location of the tornado relative to the lattice transmission tower. Three different layouts representing the change in the orientation of the tower model relative to the components of the tornado-induced loads are considered. The structural responses of the aeroelastic model in terms of base shear forces, overturning moments, and lateral accelerations are measured. The results are utilized to understand the dynamic response of self-supported transmission towers to the tornado-induced loads.

Assistive Technologies (AT) Preferences of People Living with Visual Disability as Information Access Tools in Academic Libraries

  • Adefunke Olanike Alabi;Olatokunbo Christopher Okiki
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.13 no.2
    • /
    • pp.35-50
    • /
    • 2023
  • Assistive technologies are necessary for ensuring independent living and equal participation in an information-based society for people living with disabilities (PLWD). This study investigated the assistive technology preference of students with visual disabilities, and the approach academic libraries should adopt in procuring assistive technologies. The study adopted a quantitative research method, with a survey as the research design. The study was conducted among visually disabled students in four public universities in Nigeria. Using the total enumeration method, an online questionnaire was used to obtain information from 151 students who voluntarily agreed to partake in the survey. The study found that access to electronic resources, scanning/conversion of print resources to electronic formats and access to information on the Web were among the technology-based services provided to visually disabled students. COBRA, ZoomText, Supernova and Dragon Naturally Speaking are the most preferred assistive technologies (software). At the same time, handheld scanners ($\bar{x}=4.40$) and braille keyboards ($\bar{x}=4.60$) are the most preferred assistive technologies in the hardware category by visually challenged students. The study further revealed that the library management should consult with students living with a visual disability before procuring assistive technology. Findings from this study thus provide further evidence of the need for librarians to fulfil their moral and legal obligation in advocating the provision of assistive technologies. Library administrators and university stakeholders should expedite actions on meeting the assistive technology needs of people living with visual disabilities. These actions should transcend mere policy formulation on the provision of assistive technologies to restructuring their services and spaces to accommodate assistive technologies as information service delivery tools for people with visual disabilities.

A Novel Draft Genome-Scale Reconstruction Model of Isochrysis sp: Exploring Metabolic Pathways for Sustainable Aquaculture Innovations

  • Abhishek Sengupta;Tushar Gupta;Aman Chakraborty;Sudeepti Kulshrestha;Ritu Redhu;Raya Bhattacharjya;Archana Tiwari;Priyanka Narad
    • Microbiology and Biotechnology Letters
    • /
    • v.52 no.2
    • /
    • pp.141-151
    • /
    • 2024
  • Isochrysis sp. is a sea microalga that has become a species of interest because of the extreme lipid content and rapid growth rate of this organism indicating its potential for efficient biofuel production. Using genome sequencing/genome-scale modeling for the prediction of Isochrysis sp. metabolic utilities there is high scope for the identification of essential pathways for the extraction of byproducts of interest at a higher rate. In our work, we design and present iIsochr964, a genome-scale metabolic model of Isochrysis sp. including 4315 reactions, 934 genes, and 1879 metabolites, which are distributed among fourteen compartments. For model validation, experimental culture, and isolation of Isochrysis sp. were performed and biomass values were used for validation of the genome-scale model. OptFlux was instrumental in uncovering several novel metabolites that influence the organism's metabolism by increasing the flux of interacting metabolites, such as Malonyl-CoA, EPA, Protein and others. iIsochr964 provides a compelling resource of metabolic understanding to revolutionize its industrial applications, thereby fostering sustainable development and allowing estimations and simulations of the organism metabolism under varying physiological, chemical, and genetic conditions. It is also useful in principle to provide a systemic view of Isochrysis sp. metabolism, efficiently guiding research and granting context to omics data.

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.