• Title/Summary/Keyword: CO and $CO_2$ Sensor

Search Result 886, Processing Time 0.03 seconds

Development of Gas Sensor Modules and Sensor Calibration Systems (가스 센서모듈 및 센서보정시스템 개발)

  • Park, Cheol-Young;Lim, Byung-Hun;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • Sensor is a key element in various fields of applications such as sensor networks. However, they could not be easily developed because of several factors such as temperature dependence of output characteristics and/or nonlinearity. Calibration of sensor is also needed to solve these problems. Conventional calibration process required a lot of time and expenses. Therefore, it is important to develop sensor systems which can shorten development time and minimize expense. In this paper, we develop CO and $CO_2$ Sensor modules and propose a multiple sensor calibration system to resolve problems of conventional calibration process. A proposed system is composed of sensor module, system board and monitor program. Regression analysis method based on the least mean squares is used for calibration. We introduced the structure of calibration systems and experimental results. Calibration results can be used to confirm the effectiveness of the proposed system.

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

Low Power NDIR CO2 Sensor Using LED Light Source with a Smart Device Interface (스마트 기기와 결합 가능한 LED 광원을 사용하는 저전력용 비분산 적외선 CO2센서)

  • Kim, Jong-heon;Lee, Chan-joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1606-1612
    • /
    • 2015
  • In this paper, a portable high efficiency nondispersive infrared(NDIR) $CO_2$ sensor module with a smart device interface is developed. For low power consumption design, an IR LED was used instead of tungsten lamp for light source and an optical waveguide optimized to the sensor module is designed. With the smart device interface, power of the sensor module is applied from the battery of smart phone. The measured data of the sensor module such as $CO_2$ concentration, temperature, and humidity are displayed on the smart phone using android application. From measured results, the developed sensor module shows ${\pm}60ppm$ tolerance error from 0 to 3,000ppm $CO_2$ concentration range among $-10^{\circ}C$ and $50^{\circ}C$ ranges.

3-Dimensional NiCo2O4 nanostructure prepared by hydrothermal process and its application for glucose sensor (수열합성에 의한 3차원 구조의 NiCo2O4 제조 및 글루코스 센서로서의 응용)

  • Jang, Kyu-bong;Mhin, Sungwook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.2
    • /
    • pp.78-83
    • /
    • 2021
  • In this study, we prepared NiCo2O4 nanoparticles with large surface area by hydrothermal synthesis. In order to optimize the processing conditions for spinel NiCo2O4 nanoparticles with large surface area, experimental variables including concentration of Ni and Co precursor, reaction time, and temperature for post-heat treatment were evaluated. Optimized conditions for spinel NiCo2O4 with large surface area were [Ni]/[Co] 1:2 ratio, reaction time for 12 h, and post-heat treatment at 400℃. To investigate the feasibility as potential application for glucose sensor, electrochemical tests of the prepared NiCo2O4 nanoparticles in response to glucose was performed, which suggests that the NiCo2O4 can be suitable for a non-enzymatic-based electrochemical glucose sensor based on its high sensitivity and selectivity for glucose detection.

The Measurement Method of CO2 Emission for Construction Equipment using ZigBee Sensor (ZigBee 센서를 활용한 건설장비의 CO2 배출량 측정방법)

  • Chun, Jin-Ku;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.167-174
    • /
    • 2012
  • Recently, the effort to reduce $CO_2$ emission concerning certified emission reductions (CERs) is progressing lively with the institute in the center through lifecycle. However, the technique for reduce $CO_2$ emission is the first stage yet and the technique is insufficient to calculate with accuracy it. Therefore, this study tries to develop the method to measure by actual time $CO_2$ emission of construction equipment using Zigbee sensor. To review the method that calculate $CO_2$ emission, have classified the impact factors that affect at $CO_2$ emission by IPCC guideline. It also has review the application of Zigbee sensor that use wireless data communication. The reviewed result get that the measuring objects are the $CO_2$ emssion, RPM and fuel consumption of equipment, there are needs to search the year of equipment, waiting time, kind of vehicle and fuel that affect to $CO_2$ emission.

CoAP-based Time Synchronization Algorithm in Sensor Network (센서 네트워크에서의 CoAP 기반 시각 동기화 기법)

  • Kim, Nac-Woo;Son, Seung-Chul;Park, Il-Kyun;Yu, Hong-Yeon;Lee, Byung-Tak
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.39-47
    • /
    • 2015
  • In this paper, we propose a new time synchronization algorithm using CoAP(constrained-application protocol) in sensor network environment, which handles a technique that synchronizes an explicit timestamp between sensor nodes not including an additional module for time-setting and sensor node gateway linked to internet time server. CoAP is a standard protocol for sensor data communication among sensor nodes and sensor node gateway to be built much less memory and power supply in constrained network surroundings including serious network jitter, packet losses, etc. We have supplied an exact time synchronization implementation among small and cheap IP-based sensor nodes or non-IP based sensor nodes and sensor node gateway in sensor network using CoAP message header's option extension. On behalf of conventional network time synchronization method, as our approach uses an exclusive protocol 'CoAP' in sensor network, it is not to become an additional burden for synchronization service to sensor nodes or sensor node gateway. This method has an average error about 2ms comparing to NTP service and offers a low-cost and robust network time synchronization algorithm.

Non-dispersive infrared carbon dioxide sensor with an externally exposed optical cavity (광 도파관이 외부로 노출된 구조를 가지는 비분산적외선 이산화탄소 센서)

  • Jung, Dong Geon;Lee, Junyeop;Do, Nam Gon;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.456-460
    • /
    • 2021
  • In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.

Development of NDIR CO2 Gas Detector Using Thermopile Sensor (써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발)

  • Cho, Si-Hyung;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

Development of the Electriochemical Type $CO_2$ Sensor Module using Solid Electrolyte (고체 전해질을 이용한 전기화학식 $CO_2$ 센서 모듈 개발)

  • Chung, Sung-In;Son, Jong-Dae;Lee, Seo-Hyun;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.191-194
    • /
    • 2007
  • This study focuses on the development of the Electrochemical type $CO_2$ sensor Module by using solid electrolyte which was first developed in our country. The module applied the creative fundamentals that the voltage state generated from Electro-chemical reaction using new materials is converted into $CO_2$ ppm. The study verified the accurate of Electromotive Force(EMF) through the experiment using high-impedance opamp(INA332) to measure EMF which ranges from 100mV to 600mV to be outputted from $CO_2$ sensor, and the small electric current of some nano-ampere(nA)

A Study on CO2 Sensor Module Using NDIR Method (비분산 적외선 방식의 CO2 센서 모듈에 관한 연구)

  • Kim, Gyu-Sik;Oh, Joon-Tae;Kim, Hie-Sik;Kim, Jo-Chun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • In this paper we discuss about the practical implementation of a combined CO and CO2 dual sensor module that is adapted by NDIR (Non-Dispersive Infrared) method that measures the absorbance of gas like CO and CO2 by using gas particles' characteristics that absorb specific wave lengths of infrared ray. NDIR has a long life time, excellent measurement and precision compared to the existing contact types or chemical types of CO2 sensors. Since optical cavity technology that had been developed until now can measure CO2 only we research and develop an optimal optical cavity design and density-temperature calibration technologies that can measure CO and CO2 at the same time and is important to decide the performance of the sensor module according to well-designed wave guides of the different length.