• Title/Summary/Keyword: CNCV

Search Result 23, Processing Time 0.026 seconds

Statistical Life Expectancy Calculation of MV Cables and Application Methods (중전압 전선의 통계적 수명예측 계산과 응용 방법)

  • Chong-Eun, Cho;On-You, Lee;Sang-Bong, Kim;Kang-Sik, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.61-68
    • /
    • 2022
  • In this paper, the change history of various types of MV (Medium Voltage) cables was investigated. In addition, the statistical life expectancy of each type was calculated by using the operation data and the failure data. For cut-off year, 10 years was applied, and realistically applicable statistical life expectancy was calculated by correcting the cause of failure entered by mistake. The life expectancy of FR-CNCO-W was calculated as 51.2 years, CNCV-W 38.1 years, and CNCV 31.4 years and the overall average is 33.8 years. Currently, the life expectancy of TR CNCV-W is 29.4 years, but it is estimated that the lifespan will be extended if failure data is accumulated. As a result, it is expected that life expectancy results can be applied to Asset Management System (AMS) in the future.

Lightning Impulse Breakdown Voltage Characteristics for 22.9kV TR CNCV-W Power Cable Before and After Cyclic Aging for 14days (14주기 열화에 따른 22.9kV TR CNCV-W 전력케이블의 Lightning-Impulse 파괴전압 특성분석)

  • Kim, We-Young;Heo, Jong-Cheoi;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1505-1506
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시한다. 이 과정에서 가교부산물이 제거되는 효과도 있지만 열에 의한 구조적 결함도 생기게 되며, 이들 모두가 뇌충격파괴전압에 영향을 준다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후의 파괴전압을 분석하였으며, 전반적으로 노화과정이 파괴전압을 감소시키는 결과를 보였으나 60 $mm^2$ 케이블은 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났다.

  • PDF

Partial Discharge Simulation and Analysis Based on Experiment in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Kim, Jeong-Tae;Lee, Jong-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.832-839
    • /
    • 2013
  • This paper describes the simulation and experiment for partial discharge (PD) pulse propagation in 22.9kV CNCV power cables. To investigate the propagation characteristics of PD, experiments are carried out by injecting the PD pulse in 100m-long 60 $mm^2$ CNCV cable in the laboratory. The characteristics of PD are also simulated using EMTP to investigate and analyze PD in the same cable. By comparing the simulation and test results, parameter permittivity is recalculated by considering semiconducting screen in the process of simulation and analysis of PD. After it is proved that simulation results and test results are almost similar in the laboratory, extensive simulations are performed to analyse various PD characteristics such as propagation velocity, attenuation, etc. in 60 $mm^2$ and 325 $mm^2$ CNCV cables. Authors are confident that results obtained in this paper will be used as important technical materials to detect and investigate PD generated in transmission and distribution power cables.

Diagnostic method of Insulation Deterioration for CV cable Using D.C. Potential Decay Components (직류전압 감쇄성분 측정에 관한 CV케이블의 절연열화 예측)

  • Yoo, Hyeong-Ho;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.323-328
    • /
    • 1989
  • In this paper, we studied the diagnostic method of insulation deterioration for 22.9kV CNCV cable using D.C potential decay component. At first, arbitrary D.C high voltage is appeied the CNCV cable for two minutes and switched off in vacuum. And then D.C potential decay components is measured for ten minutes. It is detecting source for cable insulation deterioration that its gradient is. Provisionally, we decided the criterion voltage and select the high voltage meter and S.W.

  • PDF

Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation (전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Joe, Sung-Hoon;Yoon, Jae-Hoon;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

AC Breakdown Voltage Characteristics of 22.9kV TR XLPE Power Cable Before and After 14days Cyclic Aging and AWTT (14주기 열화 및 AWTT에 따른 22.9kV TR CNCV-W 전력케이블의 교류파괴전압 특성분석)

  • Kim, We-Young;Heo, Jong-Cheol;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1507-1508
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시하며, XLPE 절연체에 발생하는 수트리를 가속 발생 성장시킬 목적으로 가속수트리 열화를 실시한다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후, 120, 240, 360일 가속수트리(AWTT) 후의 파괴전압을 분석하였다. 14주기노화는 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났으며, 240일 AWTT 이후에 노화가 가속되는 것으로 나타났다.

  • PDF

AC Breakdown Voltage Characteristics for 22.9kV Power Cable Before and After Cyclic Aging for 14days (14주기 열화에 따른 22.9kV 전력케이블의 교류파괴전압 특성분석)

  • Kim, We-Young;Heo, Jong-Cheol;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2271-2273
    • /
    • 2005
  • The cyclic aging for 14days is performed in order to remove the large amount of the volatiles contained in freshly manufactured cable. And the accelerated water treeing test(AWTT) is performed to accelerate the occurance of the water tree in the dielectric of XLPE. In this paper, we examined the AC breakdown voltage characteristics of the 22.9kV power cable before and after the cyclic aging for 14days and the AWTT. As the result, the AC breakdown voltage of the TR CNCV-W power cable is higher than that of CNCV-W and FR CNCO-W power cable.

  • PDF

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (전력기술.정보-22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • 전명수
    • Electric Engineers Magazine
    • /
    • s.304
    • /
    • pp.22-25
    • /
    • 2007
  • 우리 나라의 전력 계통에 있어 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간 마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전위 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A, B, C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)-51.6%(관로)의 동심 중성선 순환 전류가발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실 전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF