• Title/Summary/Keyword: CM-wire

Search Result 252, Processing Time 0.036 seconds

A System-in-Package (SiP) Integration of a 62GHz Transmitter for MM-wave Communication Terminals Applications

  • Lee, Young-Chul;Park, Chul-Soon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.182-188
    • /
    • 2004
  • We demonstrate a $2.1\;{\times}\;1.0\;{\times}\;0.1cm^3$ sized compact transmitter using LTCC System-in-Package (SiP) technology for 60GHz-band wireless communication applications. For low-attenuation characteristics and resonance suppression of the SiP, we have proposed and demonstrated a coplanar double wire-bond transition and novel CPW-to-stripline transition integrating air-cavities as well as novel air-cavities embedded CPW line. The fabricated transmitter achieves an output of 13dBm at a RF frequency of 62GHz, an IF frequency of 2.4GHz, and a LO frequency of 59.6GHz. The up-conversion gain is 11dB, while the LO signal is suppressed with the image rejection mixer below -21.4dBc, and the image and spurious signals are also suppressed below -31dBc.

Difficult airway management in a patient with a parapharyngeal tumor

  • Ji, Sung-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.153-156
    • /
    • 2015
  • A 47-year-old man was referred to the operating room to treat a dentigenous cyst of the mandibular bone. Initial assessment of the airway was considered normal. However, after the induction of anesthesia, we could not intubate the patient due to severe distortion of the glottis. Fiberoptic bronchoscopy and video laryngoscopy were not effective. Intubation using a retrograde wire technique was successful. After the conclusion of surgery, the patient recovered without any complications. Subsequent magnetic resonance imaging of the patient's neck showed a $6{\times}4{\times}8.6cm$ heterogeneous T2 hyperintense, T1 isointense well-enhancing mass in the prestyloid parapharyngeal space. The patient was scheduled for excision of the mass. We planned awake intubation with fiberoptic bronchoscopy. The procedure was successful and the patient recovered without complications. Anesthetic induction can decrease the muscle tone of the airway and increase airway distortion. Therefore, careful airway assessment is necessary.

Wear Characteristics of Submerged-Arc Cladding (서브머지드 아크 클래딩에 의한 표면 피복층의 마모특성)

  • 김권흡;권오양
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.179-186
    • /
    • 2003
  • This paper is to investigate the wear behavior of submerged-arc claddings by the wear test with a ball-on-disk type wear testing machine in air. The specimens were clad with Stoody105 alloy wire on a medium carbon steel (SM45C) substrate by submerged-arc cladding process under different welding parameters. The wear behavior of the cladding through ball-on-disk test has been studied under the wear load from 5 to 16 N and the sliding speed from 8 to 35 cm/s. The weight loss of the specimen was measured. Scanning electron micrographs of the worn surface show a layer of oxide film formed on the worn surface. Oxidation wear mechanism controls the wear process. The spatting of the oxide is caused by the repeated rubbing fatigue mechanism.

Preparation of crack-free YBCO films by EPD on silver

  • Soh, Deawha;Li, Yingmei;Korobova, N.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.359-362
    • /
    • 2003
  • Electrophoretic deposition (EPD) of alcohol YBCO suspensions on the Ag wire electrode is studied. Poly(ethylene glycol) was coordinated to a structure formed by the EPD process with YBCO particles. The suspension is characterized in terms of zeta potential and conductivity. The d.c electric fields of 200-300 V/cm are applied for 1-10 min. The optimal condition for the EPD allows modifying the properties and microstructure of the deposited films. Superconducting coatings with nanometer-sized pores and a preferred orientation along the c-axis were prepared from the result with chemically modified precursor solution. In contrast, YBCO coatings of submicrometer-sized pores and randomly orientated grains were prepared from the solution without PEG.

  • PDF

A Basic Study for the Development of Electrio-Cell Fusion Device and Performance-Improvement (전기적 세포융합기의 제작 및 성능 개선을 위한 기초 연구)

  • 이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Electrofusion of cabbage protoplasts was performed with a developed equipment which consists of a parallel wire electrode, a AC field generator, and a pulse generator. Exposure of protoplasts to an alternating current field of 450 KHz causes attraction to each other which leads to chains of protoplasts extending from the electrode. Intra-specific protoplast fusion was effectively induced within the pearl chains by the additional application of a single high-intensity DC square wave pulse of 1 KV/cm for 1-3 msec. To improve the performance, micro fusion electrode fabricated from the semiconductor technology and microcontroller based field an, d pulse generator was proposed. The viability of protoplasts after an application of electric field at optimum condition was reduced by only 5 % compared with that of pre-application. A prototype of fusion electrode, which consists of insulator-structure, was successfully fabricated by using photosensitive polyimide.

  • PDF

Experimental study on the cooling characteristics of thermosyphon for the high power electronic components (고발열 전자부품 냉각용 써모사이폰의 냉각특성에 관한 연구)

  • 김광수;김원태;송규섭;이기백
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.137-146
    • /
    • 1998
  • The experimental study is concerned with two-phase closed thermosyphons, (i.e., wickless heat pipes) for the cooling of high power electronic components in telecommunication system. The thermosyphon which can deal with a high heat flux of up to $4.9W/cm^2$ is developed, and the cooling characteristics of thermosyphon is analyzed according to design parameters which are the types of and quantity of working fluid, number of pipes, wire insertion in pipe, inclination angle of thermosyphon, and cooling air velocity. Using water as working fluid is superior cooling performance compared to using acetone, and cooling performance is improved as the number of thermosyphon becomes larger, inserting wires in the pipes, and inclination of $30~60^{\circ}$.

  • PDF

The Dependence of Mechanical Strain on a-Si:H TFTs and Metal Connection Fabricated on Flexible Substrate

  • Lee, M.H.;Ho, K.Y.;Chen, P.C.;Cheng, C.C;Yeh, Y.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.439-442
    • /
    • 2006
  • We evaluated a-Si:H TFTs fabricated on polyimide substrate (PI) at the highest temperature of $160^{\circ}C$ with uniaxial and tensile strain to imitate flexible display. With tensile strain, the threshold voltage of a-Si:H TFTs have positive shift due to extra dangling bond formation in a-Si:H layer. However, no significant degradation of the subthreshold swing and effective mobility with tensile strain of a-Si:H TFTs indicates the similar level of band tail state. The metal wire with the width of $10\;{\mu}m$ for connection on flexible substrate can sustain with curvature radius 2.5 cm.

  • PDF

An Experimental Study on Bond Strength Progress of Fold Mortar Permanent Form of Manufacturing at Field (현장 가공이 가능한 모르터 영구거푸집의 부착강도 증진을 위한 실험적 연구)

  • 김우재;김성식;임남기;김영희;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.853-858
    • /
    • 2000
  • According to the results of this research, Production of Fold Mortar Permanent - Form was found to be possible by Mortar. Th FP-Form (Fold Permanent-Form) mortar had compress strength 580kgf/$\textrm{cm}^2$. FP-Form model was made by the result of the first research. There was no minute-crack on beam form and the outer surface of form was very smooth, and those qualities it were made possible hand-mad by experiment. This study is about bond strength progress of FP-Form that developed for the form work rationalization and systematization. The result of this study follows; (1) Fluidity and strength development of mortar which used for FP-Form are satisfied (2) After study on getting good bond strength progress, inside-uneven type presents the better suitableness, and wire netting V-type presents the better shear strength.

  • PDF

Fabrication and Characteristics of Thin-film Neutron Thermopile for Reactor Instrumentation (원자로계측을 위한 박막중성자열전대의 시작 및 특성)

  • 김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.5
    • /
    • pp.1-5
    • /
    • 1972
  • In order to improve the response time of nelltron theromopile for reactor control a neutron thermopile made use of a vacuunl evaporated thin film thor mocouple was fablicated and tested. The test results were compared with a wire-type neutron thermopile. Good linearities between the response of the neutron thermopile and the thermal flux has been shown in the ranges from n/$\textrm{cm}^2$/sec. Thermal neutron flux distributions in the core of TRIGA Mark-II reactor were measured using the fabricated neutron thermopile, and the results were conpared with data obtained by the acrivatin foil measurement.

  • PDF

Operating Characteristics of Superconducting Wireless Power Transfer System for Electric Vehicle Charging (전기차 충전을 위한 초전도 무선전력전송 시스템의 동작 특성)

  • Chung, Yoon-Do;Lee, Chang-Young;Kim, Dae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.22-23
    • /
    • 2015
  • As wireless power transfer (WPT) technology using strongly coupled electromagnetic resonators is a recently explored technique to realize the large power delivery and storage without any cable or wire, this technique is required for diffusion of electric vehicles (EVs) since it makes possible a convenient charging system. Typically, since the normal conducting coils are used as a transmitting coil in the CPT system, there is limited to deliver the large power promptly in the contactless EV charging system. From this reason, we proposed the combination CPT technology with HTS transmitting antenna, In this study, we examined the improvement of transmission efficiency and properties for HTS and copper antennas, respectively, at 30 cm distance. Thus, we obtained improved transfer efficiency with HTS antenna over 10% compared with copper antenna

  • PDF