• Title/Summary/Keyword: CM method

Search Result 6,970, Processing Time 0.043 seconds

Analysis of Signal Properties in accordance with electrode area of x-ray conversion material (X선 검출 물질의 전극 면적에 따른 신호특성 분석)

  • Jeon, S.P.;Kim, S.H.;CHO, K.S.;Jung, S.H.;Park, J.K.;Kang, S.S.;Han, Y.H.;Kim, K.S.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.5-9
    • /
    • 2010
  • In recent, a digital x-ray detector attracted worldwide attention and there are many studies to commercialize. There are two methods in digital x-ray detector. This method is an Indirect method and Direct method. This study is to see the differences between the digital x-ray detector based on a-Se used in the existing indirect conversion method and an x-ray conversion material that has better SNR(Signal-to-noise ratio) and property than the a-Se. To solve the problem that is difficult to make a large area film using Screen-Print method, we used a Screen-Print method. In this study, we used a polyclystal $HgI_2$ as x-ray conversion material and a sample thickness is $150{\mu}m$ and an area is $3cm{\times}3cm$. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a Magnetron Sputtering System and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$ and then we evaluated darkcurrent, sensitivity and SNR of the $HgI_2$ film are measured, then we evaluated the electrical properties. And we used a current integration mode when I-V test. This experiment shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high darkcurrent. Through fabricating of various thicknesses and optimal electrodes, we will optimize SNR in the future work.

Effects of Cooking Method and Pasteurization Treatment on Instant Thin Rice Porridge Added with Fruits and Vegetables (조리방법 및 살균처리가 과채류를 첨가한 이유식에 미치는 영향)

  • Lee, Hwa-Jin;Kim, Soojung;Bang, Eun;Shin, Haehun;Cho, Hyung-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.569-576
    • /
    • 2016
  • This study researched the effects of cooking methods on phytochemical-enriched thin rice porridge (RP) of three colors (red, yellow, and green). Each of the RPs was prepared by three cooking methods and retorted through two-steps (step 1, at $80^{\circ}C$ for 15 min; step 2, at $82^{\circ}C$ for 25 min) for pasteurization. Cooking method (CM) 1 involved heating a mixture of all ingredients while CM 2 involved addition of apple/beet (AB, red), sweet-pumpkin/cabbage (PC, yellow) or vitamin/pear (green) while heating rice flour and glutinous rice flour. CM 3 involved mixing pre-cooked fruits and vegetables with cooked thin RP. The viscosity of RP prepared by CM 1 was lower than those of other RPs (P<0.05). The result of colorimetric a value show that red and green color of AB and VP prepared by CM 2 and CM 3 were most vivid. Contents of phytochemicals and antioxidants were higher when RP was prepared by CM 2 and CM 3 compared to CM 1. ${\Delta}E$ values of PC showed no significant difference before and after pasteurization, whereas AB and VP were significantly different (P<0.05). Antioxidant activity after retorting was not significantly different from those of un-retorted RPs. The results of color, phytochemical content, and antioxidant activity show that CM 2 or CM 3 were considerably better than CM 1, whereas cooking method had no effect after two-step retorting. Therefore, uncomplicated cooking method such as CM 1 or CM 2 are suited for commercial production of RPs.

Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography (늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가)

  • Joo, Young-Cheol;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.391-396
    • /
    • 2018
  • The purpose of this study was to compare and analyze the patient dose according to the distance between the X-ray tube focus and the image receptor, and to propose a new method for quantitatively evaluating the image quality. Using this quantitative evaluation method, the optimal distance for increasing x-ray image quality with low radiation dose was estimated between source and image receptor in Rib series radiography. Phantom images were obtained by changing the distance between focus and image receptor (100 cm and 180 cm). The patient radiation dose was estimated using entrance surface dose and dose area product. In order to evaluate image quality objectively, a non - reference image evaluation method was employed with paper and salt noise and Gaussian filter. As a result of this study, when the SID was changed from 100 cm to 180 cm, the entrance surface dose decreased by 4 ~ 5 times and the dose area product decreased by 3 times. In addition, there is no significant difference in image quality between of SID 180 cm and SID 100 cm. In conclusion, it was demonstrated that performing the rib series radiography at SID 180 cm is an optimal method to reduce the exposure dose and improve the image quality.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.318-325
    • /
    • 2003
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached the pinger is able to track comparatively easily had been developed, an availabilities of it were verified in water tank by using hydrophone and pinger. First of all, the receiving system for biotelemetry was calibrated so as to measure tracking of high precision or wide detection range. In the next place, the precision at narrow and wide beam array of receiving system by using hydrophone was investigated and the actual position was compared with measured hydrophone position. The mean standard deviations of the position by narrow beam array of receiving system were 6.4em in phase beam of fore-aft pair and 6.3em in starboard-port pair, and the wide beam array were 24em and 23em respectively. The precision of distance, position, and velocity at narrow beam array of receiving system by using pinger were investigated and the actual values were compared with measured values. The distance from receiving system to pinger was measured by the pinger synchronizing method, angle of direction of pinger was detected by the super short base line (SSBL) method. The three dimensional position of pinger to the receiving system was measured by combining of two kinds of methods (SPB method), the velocity of pinger was obtained with a differential of the three dimensional positions. The mean standard deviations of the distance by pinger synchronizing method in narrow beam array of receiving system was 1. 8 em, that of the position by SPB method was 7.7cm.

the Research on the Major Evaluation Criteria of Selecting for the China CM Corporation (중국 CM업체선정 평가단계 주요평가항목에 관한 연구)

  • Li, Zhu-Tian;Go, Seong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.213-214
    • /
    • 2015
  • The first successful case of a CM application in Shanghai, China in 1993 presented its possibility. According to the State Council's 'Investment system reformation', in 2004, more than 40 sub-provincial divisions in China were increased the productivity of construction by the CM application. It is predicted that CM will be utilized as a technical management method at government's plan, which raises the urbanization level more than 60% through the construction industry by 2020. However, compared with increasing CM demands, there are no complete evaluation criteria of CM in china. For instance, 26 areas in china arrange criteria individually, so. Therefore, it is necessary to establish integrated evaluation criteria on the basis of regional ones. This research will draw the evaluation criteria of selecting for the China CM Corporation in order to vitalize CM system.

  • PDF

The Method Improving the Productivity of a Project through Construction Management Techniques (CM의 요소기술을 이용한 프로젝트의 생산능력향상)

  • Yoon Tae-Kwon;Chung Jai-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.133-136
    • /
    • 2005
  • This study provides the method how to improve the productivity of a project using CM's constitutive methods. Construction industry in Korea was protected by the government and they have been grown with only their construction technology until today. It results Korean Construction is behind the advanced countries in terms of Engineering fields and construction management skills. This study compares the difference between the construction system of Korea and Europe and Asia. And then, it proposes the method how to compete with the other countries. which introduce the CM technique into the construction project in the beginning stage. Hopefully, this study is recognised as the basic strategy to improve the capability of Korean construction management.

  • PDF

The Molecular Orientation of PVDF Organic Thin Film by Vapor Deposition Method (진공증착법을 이용한 PVDF 유기박막의 분자배향)

  • 박수홍;이선우;임응춘;최충석;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.297-300
    • /
    • 1997
  • In this study, The PVDF thin film was fabricated on the one method of dry-process the physical vapor deposition method, applied electric field, and evaporation control in $\beta$-PVDF thin film preparation. A study on the electric-field-phase change of PVDF thin film in physical vapor deposition using the polymer deposition apparatus which are manufactured for oneself. In the analysis of Fourier-Transform Infrared spectra, according to increasing of electric field intensity, the 510$cm^{-1}$ / peak and 1273$cm^{-1}$ / peak which are showed in $\beta$-PVDF increase, on the contrary the 530$cm^{-1}$ / peak and 977$cm^{-1}$ / peak which are showed in $\alpha$-PVDF decrease.

  • PDF

Comparison of recognition rate with distance on stereo face images base PCA (PCA기반의 스테레오 얼굴영상에서 거리에 따른 인식률 비교)

  • Park Chang-Han;Namkung Jae-Chan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • In this paper, we compare face recognition rate by distance change using Principal Component Analysis algorithm being input left and right image in stereo image. Change to YCbCr color space from RGB color space in proposed method and face region does detection. Also, after acquire distance using stereo image extracted face image's extension and reduce do extract robust face region, experimented recognition rate by using PCA algorithm. Could get face recognition rate of 98.61%(30cm), 98.91%(50cm), 99.05%(100cm), 99.90%(120cm), 97.31%(150cm) and 96.71%(200cm) by average recognition result of acquired face image. Therefore, method that is proposed through an experiment showed that can get high recognition rate if apply scale up or reduction according to distance.

Study on the Crystal Growth and Characterization of GaSb treated with $Ru^{+3}$, $Pt^{+4}$ ($Ru^{+3}$, $Pt^{+4}$로 표면 처리한 GaSb의 결정 성장과 특성)

  • 이재구;오장섭;송복식;정성훈;문동찬;김선태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.77-80
    • /
    • 1995
  • GaSb crystals were grown by the vertical Bridgman method. P-type GaSb crystals were grown with Ga:Sb=1:1 at % ratio without dopants and with Te, respectively. Also, GaSb:Te crystals were investigated. Lattice constants were 6.117${\AA}$ for p-type. The carrier concentration, the resistivity, and the carrier mobility measured by the van der Pauw method were p≡8 x $10^{16}$$cm^{-3}$, p≡0.20$\Omega$-cm, ${\mu}$$_{n}$$400\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for p-type, n≡1 x $10^{17}$$cm^{-3}$, p≡0.15 $\Omega$-cm, ${\mu}$$_{n}$$500\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for n-type at 300K. In case of treating with metal ion of $Ru^{+3}$, $Pt^{+1}$, p≡2 x $10^{17}$$cm^{-3}$, p≡0.08$\Omega$-cm, ${\mu}$$_{n}$≡420$\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for p-type, n≡2.5 x $10^{17}$$cm^{-13}$, p≡0.07 $\Omega$-cm, ${\mu}$$_{n}$≡520$\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for n-type were obtained.

  • PDF