http://dx.doi.org/10.7742/jksr.2010.4.1.005

Analysis of Signal Properties in accordance with electrode area of x-ray conversion material  

Jeon, S.P. (Inje Univ. Dept of image & science)
Kim, S.H. (Inje Univ. Dept of Biomedical Engineering)
CHO, K.S. (Inje Univ. Dept of Biomedical Engineering)
Jung, S.H. (Infinitt)
Park, J.K. (International Univ. of korea Dept. of Radiological Science)
Kang, S.S. (International Univ. of korea Dept. of Radiological Science)
Han, Y.H. (Inje Univ. Dept of image & science)
Kim, K.S. (Inje Univ. Dept of image & science)
Mun, C.W. (Inje Univ. Dept of image & science)
Nam, S.H. (Inje Univ. Dept of image & science)
Publication Information
Journal of the Korean Society of Radiology / v.4, no.1, 2010 , pp. 5-9 More about this Journal
Abstract
In recent, a digital x-ray detector attracted worldwide attention and there are many studies to commercialize. There are two methods in digital x-ray detector. This method is an Indirect method and Direct method. This study is to see the differences between the digital x-ray detector based on a-Se used in the existing indirect conversion method and an x-ray conversion material that has better SNR(Signal-to-noise ratio) and property than the a-Se. To solve the problem that is difficult to make a large area film using Screen-Print method, we used a Screen-Print method. In this study, we used a polyclystal $HgI_2$ as x-ray conversion material and a sample thickness is $150{\mu}m$ and an area is $3cm{\times}3cm$. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a Magnetron Sputtering System and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$ and then we evaluated darkcurrent, sensitivity and SNR of the $HgI_2$ film are measured, then we evaluated the electrical properties. And we used a current integration mode when I-V test. This experiment shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high darkcurrent. Through fabricating of various thicknesses and optimal electrodes, we will optimize SNR in the future work.
Keywords
$HgI_2$; Sensitivity; darkcurrent; SNR; PIB;
Citations & Related Records
연도 인용수 순위
  • Reference
1 IEC6220-1:Medical Electrical Equipment Charactearistics of Digital X-ray Imaging Devices-Part 1:Determination of the Detective Quantum Efficiency (International Electrotechnical Commission, Geneva, Switzerland, 2003)
2 Robert A. Street, Steve E. Ready, L. Melekhov, et al. Approaching the Theoretical X-ray Sensitivity with HgI2 Direct Detection Image Sensors, Proc. SPIE, 2002, 4682 : 414-421
3 M. Schieber, H. Hermon, A. Zuck, et al. Polycrystalline mercuric iodide detectors, Proc. SPIE, 1999, 3770 : 146-155
4 H. Gilboa, A. Zuck, O. Dagan, et al. Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors, Proc. of the SPIE, 2001, 4784 : 315-325.
5 Zentai G, Partain L, Pavyluchova R, Proano C, Breen B, Taieb A, DaganM, SchieberMand Gilboa H: Proc. SPIE 5368 (2004) 20010
6 Street R A, Ready S E, Van Schuylenbergh K, Ho J, Boyce J B, Nylen P, Shah K, Melekhov L and Hermon H: J. Appl. Phys(2002). 91 334555
7 M. Schieber, H. Hermon, A. Zuck, A. Vilensky, L. Melekhov, R. Shatunovsky, E. Meerson,. Y. Saado, E. Pinhasy and RA. Street: J. Crystal Growth 225(2001)118-123   DOI   ScienceOn