• Title/Summary/Keyword: CM method

Search Result 6,970, Processing Time 0.036 seconds

Major Risk Factors to Implement CM at Risk Pilot Project on the Public Sector (시공책임형 CM 발주방식 공공부문 시범사업 사례를 통한 리스크 도출)

  • Han, Jonghoon;Kim, Kyungtae;Ahn, Yonghan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.3
    • /
    • pp.61-69
    • /
    • 2018
  • The buildings are getting enormous and more complex as well as the requirement of the owner which wants diverse and efficient. Moreover advanced management is necessary for construction services and a new method of delivering project is now required. In order to expand the delivering method and the construction industry, we have to introduced the CM at Risk method. However, despite the fact that six years have passed already the CM at Risk regulation was introduced, the contract amount in significantly lower than that of the CM for fee, and also there is no CM at Risk project in the public sector. As a result, three pilot projects are currently underway for the LH(Korea Land & Housing Corporation) in order to set up a CM at Risk for the public sector. However, detailed regulations related to CM at Risk have not yet been implemented in Korea. Therefore, in this study, I am trying to understand the risks that could incur when practitioners participate in the three pilot projects that are currently underway and employed in the public sector wherein the CM at Risk is normally introduced. Based on the results of this study, It will be able to utilize as a basic data for future CM at Risk delivery system improvement and enactment.

Effective Dispersion of Electrode Catalysts for Direct Formic Acid Fuel Cells by Electrospray Method (정전분무법을 이용한 직접개미산 연료전지 전극촉매의 효율적인 분산)

  • Kwon, Byeong-Wan;Kim, Jin-Soo;Kwon, Yong-Chai;Han, Jong-Hee
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.4
    • /
    • pp.262-267
    • /
    • 2008
  • Effective dispersion of noble metal Pt-Ru catalysts was conducted for the application of direct formic acid fuel cell(DFAFC) electrodes by electrospray method. The amount of catalysts deposited on the electrodes increased with increasing deposition time. However, the performance of cell test decreased with the deposition time after 80 min. because of agglomeration of catalysts. With the conventional hand-spray method, the density of the anode catalysts deposited was $3.0\;mg/cm^2$ and the maximum power density of the MEA was $74\;mW/cm^2$. On the other hand, the MEA prepared by the electrospray method, showed a similar power density of $72\;mW/cm^2$. However, the density of the anode catalysts deposited was much lower than the case of the hand-spray and the density the anode catalysts in this case was $1.85\;mg/cm^2$.

Measurement of nonlinear optical constant of organic single crystal para-toluene sulfonate prepared by slow solution evaporation method (늦은 용액증발법으로 제작한 유기단결정 para-toluene sulfonate의 비선형 광학상수 측정)

  • 황보창권
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.76-85
    • /
    • 1998
  • Organic single crystal of p-toluene sulfonate(PTS) bulks and thin films were fabricated using a slow solution evaporation method. Third and fifth order nonlinear refractive indices, $n_2$and $n_3$, of PTS crystals at 1600 nm were determined by the Z-scan method and the multimode output of the PTS thin film waveguide was observed at 1350 nm. When the beam intensity is in 2-5 GW/$cm^2$, the nonlinear refractive indices are $n_{2}=6{\times}10^{-4}cm^{2}$/GW and $n_{3}=-7{\times}10^{-5}cm^{4}/GW^{2}$ and the two and three photon absorption coefficients are zero. When the beam intensity is in 5~16 GW/$cm^2$, the split-step fast Fourier transform beam propagation method simulation shows that the beam propagation in the PTS is distorted from the gaussian shape.

  • PDF

The Preliminary Study on the Quantitative Analysis of Quarts by Fourier Transform Infrared Spectrophotometric Direct on Filter(FTIR-DOF) Method -Effects of filter materials, inhomogeneity of deposition, and humidity- (Fourier Transform Infrared Spectrophotometric Direct on Filter 방법을 이용한 석영 분석의 기초 연구 - 필터재질, 비균일 침착 및 습도의 영향 -)

  • Phee, Young Gyu;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Although the Fourier Transform Infra-Red spectrophotometric Direct on Filter(FTIR-DOF) method is a useful analytical technique for quantifying quartz content in respirable dust samples, a number of analytical problems must be taken into consideration such as, to name only a few, inhomogeneous deposition of particles, level of environmental humidity, uneven surface of the filter, and interfering minerals in the sample. This study was designed to select the most suitable wavelength and proper filter material for the method, and to investigate effects of humidity and inhomogeneous deposition of particles on the filter. Samples of respirable dust, created in a dust chamber containing standard material of quartz, were collected using a cyclone equipped with a 25mm filter as a collection medium. The results were as follows; 1. Among seven (7) commercially available filters tested for the FTIR-DOF method, the DM 800 filter showed the best analytical performance having the lowest background absorbance bands and no overlapping peaks at 799, 779, and $695cm^{-1}$. 2. The variations of absorbance due to humidity ranged from 1.0% to 3.3% for $799cm^{-1}$, 1.0% to 3.3% for $779cm^{-1}$, and 8.9%~20.9% for $695cm^{-1}$ peaks, respectively. The $699cm^{-1}$ peak was proved to be most vulnerble to environmental humidity for quantitative analysis of quartz. 3. As for effects of inhomogeneous deposition of samples, the highest variation of absorbance of 10.9% ($13.5{\mu}g$) was observed when using the 695cm-1. The variations of absorbance from the other two peaks, 799 and $779cm^{-1}$, ranged from 1.2 to 3.2%, and 1.4 to 4.1%, respectively. Therefore, the $799cm^{-1}$ peak was considered to be most reliable for quantitative analysis of quartz. The results of this study suggest that, for quantitative analysis of quartz in the respirable dust samples, use of the $799cm^{-1}$ peak can minimize the influence of environmental humidity and inhomogeneous deposition of particles on the filter. The FTIR-DOF method, if adopted for routine analysis of quartz in the respirable dust samples, could save sample preparation time and efforts substantially and also could increase analytical throughputs. Since use of the $799cm^{-1}$ peak is prone to be affected by interferences in the sample, further research on minimizing the effects is needed.

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Improvement of Pesticide Sorption Measurement Method for Soils with Low Sorption (흡착력(吸着力)이 낮은 토양(土壤)에서의 농약흡착(農藥吸着) 측정법(測定法) 개발(開發))

  • Kim, Sun-Kwan;Green, Richard E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.2
    • /
    • pp.124-129
    • /
    • 1991
  • A mass balance method which measures directly both the sorbed pesticide and equilibrium solution concentration was compared with the batch method in a hypothetical experiment to determine the precision of sorption measurement. The mass balance method was shown to improve precision of sorption measurement. The two methods were also tested experimentally on the Wahiawa soil, 0-20, 40-60 and 100-120 cm, and Salinas soil, 0-15 and 115-130 cm. The mass balance method greatly improved precision of sorption measurement on the deep Wahiawa subsoil having the lowest sorption. The coefficient of variation (CV) for $K_d$ measurement was 20.3% for the batch method and 8.4% for the mass balance method. For other soil samples tested, precision of the batch method was relatively high but was still improved by the mass balance method.

  • PDF

Comparative Antimicrobial Susceptibility by the Methods of Test (검사방법(檢査方法)에 따르는 항균제감수성(抗菌劑感受性)의 비교(比較))

  • Park, Dong-Choon;Chun, Do-Ki
    • The Journal of the Korean Society for Microbiology
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 1978
  • The difference in antimicrobial susceptibility of multiply drug-resistant Salmonella typhi by the methods of test was tested against chloramphenicol(Cm), tetracycline(Tc), ampicillin(Ap), kanamycin(Km), and rifampicin(Rif), and the results were compared by the minimum inhibitory concentration(MIC). No appreciable difference was noted between MICs of Cm, Tc, and Rif measured by agar plate dilution(plate) method and broth dilution(broth) method. However, MICs of Km to about a half of test strains were 4 to 8-fold higher by broth method than plate method, and MICs of Ap by broth method were also a little higher than plate method in some strains. Cm and Rif were bacteriostatic rather than bactericidal to the most of test strains in high concentrations. Tc, Ap and Km were exclusively bactericidal to the test strains.

  • PDF

Experimental and numerical studies of the pre-existing cracks and pores interaction in concrete specimens under compression

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.23 no.5
    • /
    • pp.479-493
    • /
    • 2019
  • In this paper, the interaction between notch and micro pore under uniaxial compression has been performed experimentally and numerically. Firstly calibration of PFC2D was performed using Brazilian tensile strength, uniaxial tensile strength and biaxial tensile strength. Secondly uniaxial compression test consisting internal notch and micro pore was performed experimentally and numerically. 9 models consisting notch and micro pore were built, experimentally and numerically. Dimension of these models are 10 cm*1 cm*5 cm. the length of joint is 2 cm. the angularities of joint are $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. For each joint angularity, micro pore was situated 2 cm above the lower tip of the joint, 2 cm above the middle of the joint and 2 cm above the upper of the joint, separately. Dimension of numerical models are 5.4 cm*10.8 cm. The size of the cracks was 2 cm and its orientation was $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. Diameter of pore was 1cm which situated at the upper of the notch i.e., 2 cm above the upper notch tip, 2 cm above the middle of the notch and 2 cm above the lower of the notch tip. The results show that failure pattern was affected by notch orientation and pore position while uniaxial compressive strength is affected by failure pattern.

A Study on Characteristics Analysis of Common-Mode Choke with Reduced Parasitic Capacitance (기생 커패시턴스 저감형 공통모드초크의 특성해석에 관한 연구)

  • Won, Jae-Sun;Kim, Hee-Seung;Kim, Jong-Hae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.137-143
    • /
    • 2015
  • This paper presents the intra capacitance modeling based on the winding method and section bobbin for CM choke capable of EMI attenuation of broad bands from lower to higher frequency bands and high frequency type common-mode choke capable of EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. The case of high frequency type CM choke can be explained by the parasitic capacitance of three types of CM choke. The winding method of section bobbin type is smaller than the others. The first resonant frequency of the proposed CM choke tends to increase as the parasitic capacitance becomes small and its impedance characteristics improved performance as the first resonant frequency increases. The CM chokes of the proposed section bobbin type shows that in the future, the method may have practical use in LED/LCD-TV SMPS and in several applications, such as LED lighting, adapters, and so on.

An Analysis of the Rectangular Plates on an Winkler's Foundtion (Winkler 地盤上에 놓인 矩形板의 解析)

  • Park, Geun-Su
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.1
    • /
    • pp.49-56
    • /
    • 1992
  • This study was carried out to investigate the mechanical behaviour of the plate on a Winkler's foundation according to the soil-structures relative stiffness and the applicability of the conventional analysis method. For the above purpose, Winkler's constant of 4, 15, 25 and 100kg/$cm^2$/cm was considered and the plate thickness of 20, 30, 50, 100 and 150cm was adopted. Results obtained from the numerical examples are summarized as follow: 1. The effects of elastic foundation is considerable for plates with small flexural rigidity. 2. As the Winkler's constant increases, the bending moment in the plate becomes localized near the loading point. 3. The stresses evaluated by the conventional method not correct even for rigid ground such as rock. 4. If the relative stiffness of the plate is very large, for example the plate thickness is larger than 100cm, the conventional analysis method can be justified for the design purposes. 5. On assumption the flexural rigidity of the plate is infinite, the interaction of soil and plate can be ignored in design consideration. The numerical examples in this paper show that when the plate thickness is more than 100cm, the effects of elastic foundation almost disappear. In practical design, soil-plate interaction should be taken into account, because the 100cm-thickness of the plate will not be practical value in usual sites.

  • PDF