• Title/Summary/Keyword: CM Function

Search Result 1,490, Processing Time 0.038 seconds

Effects of Alginic Acid, Cellulose and Pectin Level on Bowel Function in Rats (알긴산과 셀룰로오스 및 펙틴 수준이 흰쥐의 대장기능에 미치는 영향)

  • 이형자
    • Journal of Nutrition and Health
    • /
    • v.30 no.5
    • /
    • pp.465-477
    • /
    • 1997
  • The purpose of this article is to know the effects on bowel function of the kind of fiber and the amount of fiber in SD-rats. To do this experiment, we select of $\alpha$-cellulose as n insoluble cellulose source and alginic acid and pectin as soluble cellulose source. The rats diets contained callolose camcentrations of 1.0%, 3.6%, 6.0% and 10.0%. After that, we raised the SD-rats for 4weeks and measured the amount of food intake, body weight, the food effciency ratio, the length of liver and stomach the weight of the intestines, the transit time through the intestines, pH in feces, and the amount of bile acid and Ca, Mg, pp. 1) The amount of food intake was 15.75-31.00g/day. It was highest in the 10.0% cellulose group and the lowest in the 3.6% and 6.0% alginic acid group (p<0.05). The body weights of rats were 277.50-349.809. It was highest in the 1.0% pectin group and lowest in the 3.6% alginic acid group, 6.0% cellulose group, and 10.0% pectin group. It had differences according to the content fiber and the kind of dietary(p<0.01). The food efficiency ratio was (p<0.01). The higher the content of dietary fiber, the lower the calory and the food efficiency ratio. 2) Transit time was 446.0-775.0 minutes and it showed signidicant ifferences according to the content and kind of dietary fiber(p<0.01). It was long in the 1.0% cellulose group and 1.0% pectin group but short in the 10.0% alginic acid group. As the content of dietary fiber increased, the transit time through the intestines was shortened. The length of small intestine was 101.03-120.40cm and there were no difference cegardloss of the content and kind of fiber. The length of the large intestine was 20.92-25.42cm and there were significant differences according to the content and kind of the fiber. High-fiber diets resulted in increases in the length of the large intestine. 3) The weight of the liver was 8.68-10.96g and there were no differences according to the content and kind of fiber. The weight of stomach was 1.28-1.74g and there were no differences resulting from the kind of dietary fiber, but it was highest in the 10.0% alginic acid group. The weight of the small intestine was 5.52-8.04g with no difference resulting from to the kind of fiber. It was highest in the 10.0% the alginic acid group and lowest in the 1.0% alginic acid group(p<0.05). The weight of large intestine was 2.50-3.30g with no differences related to the kind of dietary fiber. It was heaviest in the 6.0% and 10.0% alginic acid groups and in the 10.0% pectin group with differences related to the content of fiber(p<0.05). 4) The pH of the feces was 5.82-6.86 according to the kind of dietary fiber, alginic acid group was high at 6.66, the cellulose group was 6.26. but the pectin group was low at 6.30. There were difference according to the content of fiber, but no consistency. The content of bile acid was 6.25-34.77umol per 1g of dry feces. According to the kind of dietary fiber, the alginic acid group was low at 12.91umol, cellulose group was 18.64umol and, the pectin group was the highest at 27.78umol(p<0.001). Based on the content of dietary fiber, alginic acid group was low at 1.0%, but high at 3.6% pectin group(p<0.001). 5) The amount of feces was 1.00-5.10g/day. The weight of rat feces was 2.23g/day in the alginic acid goup, 2.75g/day in the cellulose group, and 1.82g/day in the pectin group. According to the content of fiber, cellulose group was high at 10.0% but alginic acid group was 1.0%, and there were significant difference according to the dietary fiber. The more the content of fiber, the more increase the content of feces in alginic acid, cellulose and pectin group. The content of Ca in the feces was 80.10-207.82mg/1g of dry feces. In the dietary fiber, alginic acid group was 193.08mg, cellulose group was 87.5mg, pectin group was 138.16mg. In the content of fiber, alginic acid group was high at 1.0% and 3.6% but low at 10.0% of Pectin group. The content of Mg was 19.15-44.72mg/1g of dry feces. According to the kind of dietary fiber, alginic acid group was 35.33mg, cellulose group was 23.60mg, and pectin was 36.93mg. According to the content of fiber, pectin group was high at 1.0% and low at 10.0% of cellulose group. The content of P was 1.65-4.65mg/1g of dry feces. According to the kind of dietary fiber, alginic acid group 2.23mg/g dry feces, cellulose group was 2.29mg/g, pectin group wa 4.08mg/g dry feces. In the content of fiber, pectin group was high at 6.0% and low at 6.0% alginic acid group, but there were significant difference among the analysis value. The conetnt of Ca and MG was higher in soluble alginic acid group and pectin group than in insoluble cellulose group. The high the content of the dietary fiber, the lower the food efficiency ratio and the short the transit time through intestine with the increase of the length of large intestin as well as the higher level of the stomach, the small intestine and the large intestine. According to the content of the dietary fiber, the amount of the feces, Ca, Mg and P was increased but the length the small intestin, the weight of liver, pH of the feces and the amount of bile acid showed no differences and consistency.

  • PDF

Dose Response Relationship in Local Radiotherapy for Hepatocellular Carcinoma (원발성 간암의 국소 방사선치료 시 선량반응 관계)

  • Park Hee Chul;Seong Jinsil;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Song Jae Seok;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.118-126
    • /
    • 2001
  • Purpose : In this study, it was investigated whether dose response relation existed or not in local radiotherapy for primary hepatocellular carcinoma. Materials and Methods : From January 1992 to March 2000, 158 patients were included in present study. Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two thirds of the entire liver, and performance status on the ECOG scale of more than 3. Radiotherapy was given to the field including tumor with generous margin using 6, 10-MV X-ray. Mean tumor dose was $48.2{\pm}7.9\;Gy$ in daily 1.8 Gy fractions. Tumor response was based on diagnostic radiologic examinations such as CT scan, MR imaging, hepatic artery angiography at $4\~8$ weeks following completion of treatment. Statistical analysis was done to investigate the existence of dose response relationship of local radiotherapy when it was applied to the treatment of primary hepatocellular carcinoma. Results : An objective response was observed in 106 of 158 patients, giving a response rate of $67.1\%$. Statistical analysis revealed that total dose was the most significant factor in relation to tumor response when local radiotherapy was applied to the treatment of primary hepatocellular carcinoma. Only $29.2\%$ showed objective response in patients treated with dose less than 40 Gy, while $68.6\%\;and\;77.1\%$ showed major response in patients with $40\~50\;Gy$ and more than 50 Gy, respectively. Child-Pugh classification was significant factor in the development of ascites, overt radiation induced liver disease and gastroenteritis. Radiation dose was an important factor for development of radiation induced gastroduodenal ulcer. Conclusion : Present study showed the existence of dose response relationship in local radiotherapy for primary hepatocellular carcinoma. Only radiotherapy dose was a significant factor to predict the objective response. Further study is required to predict the maximal tolerance dose in consideration of liver function and non-irradiated liver volume.

  • PDF

Preparation of Soluble Dietary Fiber from Oak Wood (Quercus Mongolica) and Its Physiological Function in Rat Fed High Cholesterol Diets (참나무 (Quercus Mongolica)로부터 수용성 식이섬유소의 제조 및 기능성 검증)

  • 채영미;임부국;이종윤;김영희;이순재
    • Journal of Nutrition and Health
    • /
    • v.36 no.1
    • /
    • pp.9-17
    • /
    • 2003
  • The preparation method of a soluble dietary fiber from oak wood (Quercus mongolica) and the effect of the soluble dietary fiber on physiological function in rat fed high cholesterol diets was investigated. The best condition for steam explosion method was 25 kgf/㎤ pressure for 6 min. The exploded samples were delignified by the filtration treatment with 1% NaOH for several times, which is the best condition. The enzymatic hydrolysis of Cellusoft cellulase was more effective than Onozuka R-10 cellulase. The manufactured soluble dietary fiber was assayed using gel permeation chromatography (GPC) and it was dissolved in water. Average molecular weight distribution of manufactured soluble dietary fiber was about 348-1,200 and it was assumed the oligomer form fraction. In order to compare the manufactured soluble dietary fiber with commercial soluble dietary fiber (pectin) on the physiological function, Sprague-Dawley male rats weighing 100$\pm$10 g were randomly assigned to one normal diet and five high cholesterol diet containing 1% cholesterol. The high cholesterol diet groups were classified to fiber free diet (FF group), 5% pectin (5P group), 10% pectin (l0P group), 5% manufactured soluble dietary fiber (5M group) and 10% manufactured soluble dietary fiber (10M group). Body weight gains in all soluble dietary fiber groups were lower than FF group. Food intakes were increased in all soluble dietary fiber groups than that of FF group. Food efficiency ratio (FER) was significantly decreased in all soluble dietary fiber groups than that of the FF group, and it was especially was highest in 10% supplemented soluble dietary fiber group. The weight of liver of the soluble dietary fiber supplemented groups were lower than those of the FF group, but weights of cecum and small intestine of all supplemented soluble dietary fiber groups were significantly increased, compared with that of FF group. The weights and water contents in feces were significantly increased by the soluble dietary fiber. The activity of the glutamic oxaloacetic transaminase in soluble dietary fiber groups were significantly decreased than those of FF group. The hepatic glutathione S-transferase activity in all soluble dietary fiber supplemented groups were higher than that of FF group. The physiological effects of the manufactured soluble dietary fiber are the same as the commercial soluble dietary fiber (pectin). The preparation method of the soluble dietary fiber from the oak chips suited to its purpose. (Korean J Nutrition 36(1) : 9~17, 2003)

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

A Reliability Analysis of Shallow Foundations using a Single-Mode Performance Function (단일형 거동함수에 의한 얕은 기초의 신뢰도 해석 -임해퇴적층의 토성자료를 중심으로-)

  • 김용필;임병조
    • Geotechnical Engineering
    • /
    • v.2 no.1
    • /
    • pp.27-44
    • /
    • 1986
  • The measured soil data are analyzed to the descriptive statistics and classified into the four models of uncorrelated-normal (UNNO), uncorrelated-nonnormal (VNNN), correlatedonnormal(CONN), and correlated-nonnormal(CONN) . This paper presents the comparisons of reliability index and check points using the advanced first-order second-moment method with respect to the four models as well as BASIC Program. A sin91e-mode Performance function is consisted of the basic design variables of bearing capacity and settlements on shallow foundations and input the above analyzed soil informations. The main conclusions obtained in this study are summarized as follows: 1. In the bearing capacity mode, cohesion and bearing-capacity factors by C-U test are accepted for normal and lognormal distribution, respectively, and negatively low correlated to each other. Since the reliability index of the CONN model is the lowest one of the four model, which could be recommended a reliability.based design, whereas the other model might overestimate the geotechnical conditions. 2. In the case of settlements mode, the virgin compression ratio and preccnsolidation pressure are fitted for normal and lognormal distribution, respectively. Constraining settlements to the lower ones computed by deterministic method, The CONN model is the lowest reliability of the four models.

  • PDF

The Effect of the Histidine-Tryptophan-Ketoglutarate (HTK) Solution on Myocardial Protection in Isolated Rat Heart (흰쥐의 적출심장에서 HTK 용액의 심근보호 효과)

  • 송원영;장봉현;김규태
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.632-643
    • /
    • 2004
  • Background: The Histidine-Tryptophan-Ketoglutarate (HTK) solution has been shown to provide the excellent myocardial protection as a cardioplegia. The HTK solution has relatively low potassium as an arresting agent of myocardium, and low sodium content, and high. concentration of histidine biological buffer which confer a buffering capacity superior to that of blood.. Since HTK solution has an excellent myocardial protective ability, it is reported to protect myocardium from ischemia for a considerable time (120 minutes) with the single infusion of HTK solution as a cardioplegia. The purpose of this study is to evaluate the cardioprotective effect of HTK solution on myocardium when the ischemia is. exceeding 120 minutes at two different temperature (10 to 12$^{\circ}C$, 22 to 24$^{\circ}C$) using the Langendorff apparatus, Material and Method: Hearts from Sprague-Dawley rat, weighing 300 to 340 g, were perfused with Krebs-Henseleit solution at a perfusion pressure of 100 cm $H_2O$. After the stabilization, the heart rate, left ventricular developed pressure (LVDP), and coronary flow were measured. Single dose of HTK solution was infused into the ascending aorta of isolated rat heart and hearts were preserved at four different conditions. In group 1 (n=10), hearts were preserved at deep hypothermia (10∼12$^{\circ}C$) for 2 hours, in group 2 (n=10), hearts were preserved at moderate hypothermia (22∼24$^{\circ}C$) for 2 hours, in group 3 (n=10), hearts were preserved at deep hypothermia for 3 hours, and in group 4 (n=10), hearts were preserved at moderate hypothermia for 3 hours. After the completion of the preservation, the heart rate, left ventricular developed pressure, and coronary flow were measured at 15 minutes, 30 minutes, and 45 minutes after the initiation of reperfusion to assess the cardiac function. Biopsies were also done and mitochondrial scores were counted in two cases of each group for ultrastructural assessment. Result: The present study showed that the change of heart rate was not different between group 1 and group 2, and group 1 and group 3. The heart rate was significantly decreased at 15 minutes in group 4 compared to that of group 1 (p<0.05 by ANCOVA). The heart rate was recovered at 30 minutes and 45 minutes in group 4 with no significant difference compared to that of group 1. The decrease of LVDP was significant at 15 minutes, 30 minutes and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). Coronary flow was significantly decreased at 15 minutes, 30 minutes, and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). In ultrastructural assessment, the mean myocardial mitochondrial scores in group 1, group 2, group 3, and group 4 were 1.02$\pm$0.29, 1.52$\pm$0.26, 1.56$\pm$0.45, 2.22$\pm$0.44 respectively. Conclusion: The HTK solution provided excellent myocardial protection regardless of myocardial temperature for 2 hours. But, when ischemic time exceeded 2 hours, the myocardial hemodynamic function and ultrastructural changes were significantly deteriorated at moderate hypotherma (22∼ 24$^{\circ}C$). This indicates that it is recommended to decrease myocardial temperature when myocardial ischemic time exceeds 2 hours with single infusion of HTK solution as a cardioplegia.

An Experimental Study on Real Time CO Concentration Measurement of Combustion Gas in LPG/Air Flame Using TDLAS (TDLAS를 이용한 LPG/공기 화염 연소가스의 실시간 CO 농도 측정에 관한 연구)

  • So, Sunghyun;Park, Daegeun;Park, Jiyeon;Song, Aran;Jeong, Nakwon;Yoo, Miyeon;Hwang, Jungho;Lee, Changyeop
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • In order to enhance combustion efficiency and reduce atmosphere pollutants, it is essential to measure carbon monoxide (CO) concentration precisely in combustion exhaust. CO is the important gas species regarding pollutant emission and incomplete combustion because it can trade off with NOx and increase rapidly when incomplete combustion occurs. In the case of a steel annealing system, CO is generated intentionally to maintain the deoxidation atmosphere. However, it is difficult to measure the CO concentration in a combustion environment in real-time, because of unsteady combustion reactions and harsh environment. Tunable Diode Laser Absorption Spectroscopy (TDLAS), which is an optical measurement method, is highly attractive for measuring the concentration of certain gas species, temperature, velocity, and pressure in a combustion environment. TDLAS has several advantages such as sensitive, non-invasive, and fast response, and in-situ measurement capability. In this study, a combustion system is designed to control the equivalence ratio. Also, the combustion exhaust gases are produced in a Liquefied Petroleum Gas (LPG)/air flame. Measurement of CO concentration according to the change of equivalence ratio is confirmed through TDLAS method and compared with the simulation based on Voigt function. In order to measure the CO concentration without interference from other combustion products, a near-infrared laser at 4300.6 cm-1 was selected.

Diversity, Spatial Distribution and Ecological Characteristics of Relict Forest Trees in South Korea (한국 산림유존목의 다양성, 공간 분포 및 생태 특성)

  • CHO, Hyun-Je;Lee, Cheol-Ho;Shin, Joon-Hwan;Bae, Kwan-Ho;Cho, Yong-Chan;Kim, Jun-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.401-413
    • /
    • 2016
  • Forest resources utilization and variable disturbance history have been affected the rarity and conservation value of forest relict trees, which served as habitat for forest biodiversity, important carbon stock and cultural role include human and natural history in South Korea. This study was conducted to establish the baseline data for forest resources conservation by clarifying species diversity, spatial distribution and ecological characteristics (individual and habitat) of forest relict trees (DBH > 300 cm) based on the data getting from mountain trail, high resolution aerial photos and field professionals and field survey. As results, 54 taxa (18 family 32 genus 48 species 1 subspecies 3 variety and 2 form) as about 22% of tree species in Korea was identified in the field. 837 individuals of forest relict trees were observed and the majority of the trees was in Pinaceae, deciduous Fagaceae and Rosaceae, which families are abundant in population diversity. High elevation area was important to relict trees as mean altitudinal distribution was 1,200 m a.s.l as likely affected by human activity gradients and mid-steep slope and North aspect was important environment for the trees remain. Many individuals exhibited 'damage larger branch' (55.6%) and consequent relatively lower mean canopy coverages (below 80%). Synthetically, present diversity and abundance of relict forest trees in South Korea were the result of complex process among climate variation, local weather and biological factors and the trees of big and old were estimated to important forest biodiversity elements. In the future, clarifying the role and function of relict trees in forest ecosystem, in- and ex- situ programmes for important trees and habitat, and activities for building the background of conservation policy such as "Guideline for identifying and measurement of forest relict trees".

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF