• 제목/요약/키워드: CM Function

검색결과 1,483건 처리시간 0.03초

드롭착지 동작 시 체간모델에 따른 척추분절운동이 자세안정성 해석에 미치는 영향 (The Effect Analysis of Postural Stability on the Inter-Segmental Spine Motion according to Types of Trunk Models in Drop Landing)

  • 유경석
    • 한국운동역학회지
    • /
    • 제24권4호
    • /
    • pp.375-383
    • /
    • 2014
  • The purpose of this study was to assess the inter-segmental trunk motion during which multi-segmental movements of the spinal column was designed to interpret the effect of segmentation on the total measured spine motion. Also it analyzed the relative motion at three types of the spine models in drop landing. A secondary goal was to determine the intrinsic algorithmic errors of spine motion and the usefulness of such an approach as a tool to assess spinal motions. College students in the soccer team were selected the ten males with no history of spine symptoms or injuries. Each subject was given a fifteen minute adaptation period of drop landing on the 30cm height box. Inter-segmental spine motion were collected Vicon Motion Capture System (250 Hz) and synchronized with GRF data (1000 Hz). The result shows that Model III has a more increased range of motion (ROM) than Model I and Model II. And the Lagrange energy has significant difference of at E3 and E4 (p<.05). This study can be concluded that there are differences in the three models of algorithm during the phase of load absorption. Especially, Model III shows proper spine motion for the inter-segmental joint motion with the interaction effects using the seven segments. Model III shows more proper observed values about dynamic equilibrium than Model I & Model II. The findings have shown that the dynamic stability strategy of Model III toward multi-directional spinal motion supports for better function of the inter-segmental motor-control than the Model I and Model II.

High Performance GaN-Based Light-Emitting Diodes by Increased Hole Concentration Via Graphene Oxide Sheets

  • Jeong, Hyun;Jeong, Seung Yol;Jeong, Hyun Joon;Park, Doo Jae;Kim, Yong Hwan;Kim, HyoJung;Lee, Geon-Woong;Jeong, Mun Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.244.1-244.1
    • /
    • 2013
  • The p-type GaN which act as a hole injection layer in GaN-based LEDs has fundamental problems. The first one arises from the difficulty in growing a highly doped p-GaN (with a carrier concentration exceeding ~1018 $cm^{-3}$). And the second one is the absence of appropriate metals or conducting oxides having a work function that is larger than that of p-type GaN (7.5 eV). Moreover, the LED efficiency is decreases gradually as the injection current increases (the so-called 'efficiency droop' phenomenon). The efficiency droop phenomenon in InGaN quantum wells (QWs) has been a large obstacle that has hindered high-efficiency operation at high current density. In this study, we introduce the new approaches to improve the light-output power of LEDs by using graphene oxide sheets. Graphene oxide has many functional groups such as the oxygen epoxide, the hydroxyl, and the carboxyl groups. Due to nature of such functional groups, graphene oxide possess a lot of hole carriers. If graphene oxide combine with LED top surface, graphene oxide may supply hole carriers to p-type GaN layer which has relatively low free carrier concentration less than electron concentration in n-type GaN layer. To prove the enhancement factor of graphene oxide coated LEDs, we have investigated electrical and optical properties by using ultra-violet photo-excited spectroscopy, confocal scanning electroluminescence microscopy.

  • PDF

롤투롤 스퍼터 시스템을 이용하여 PET 기판위에 성막 시킨 ITO 박막의 특성 연구 (Characteristics of Indium Tin Oxide Films Grown on PET Substrate Grown by Using Roll-to-Roll (R2R) Sputtering System)

  • 조성우;최광혁;배정혁;문종민;정진아;정순욱;박노진;김한기
    • 한국재료학회지
    • /
    • 제18권1호
    • /
    • pp.32-37
    • /
    • 2008
  • The electrical, optical, structural and surface properties of an indium tin oxide (ITO) film grown on a flexible PET substrate using a specially designed roll-to-roll (R2R) sputtering system as a function of the DC power, $Ar/O_2$ flow ratio, and rolling speed is reported. It was observed that both the electrical and optical properties of the ITO film on the PET substrate were critically dependent on the $Ar/O_2$ flow ratio. In addition, x-ray diffraction examination results showed that the structure of the ITO film on the PET substrate was an amorphous structure regardless of the DC power and the $Ar/O_2$ flow ratio due to a low substrate temperature, which was maintained constant by a main cooling drum. Under optimized conditions, ITO film with resistivity of $6.44{\times}10^{-4}{\Omega}-cm$ and transparency of 86% were obtained, even when prepared at room temperature. Furthermore, bending test results exhibited that R2R-grown ITO film had good flexibility which would be applicable to flexible displays and solar cells.

담결석(膽結石)의 한의학적(韓醫學的) 문헌적고찰(文獻的考察) (A Oriental Medical study on the Gallstone therapeutics)

  • 김명동;박용인
    • 동의생리학회지
    • /
    • 제14권2호통권20호
    • /
    • pp.23-41
    • /
    • 1999
  • The disease of cholelith is common world widely. As life expectancy gets extended and life environment and dietary life change, increased to gallstone in Korea. On the case that elimination surgery is inapplicable and for the aged patients. recently the dissolution therapy of cholelith is studied world widely. From the view of oriental medicine, the causes of gallstone, treatment methods and the effects of therapy are as follows ; 1. The attack of gallstone is by the stagnation and disturbance of qi in the body. 2. The causes of gallstone are classified into three types. 1).The type of stagnation of qi. 2).The type of damp-heat. 3).The type of noxious heat. 3. The treatment effect is high in the damp-heat type. 4. Medical treatment of gallstone, considering the function of the intestines, are lithodialysis and removol of gallstone, soothing the liver and regulating the cerculation of qi, clearing away heat and elininating dampness. 5. The dissolution therapy of gallstone effected to the size within the diameter of 1.5cm 6. Through the oriental medicine therapy, besides excretion and dissolution of gallstone, the interval extention and elimination of spasm, the prevention of relapse and aftere effect are to be expected. The study which can improve the treatment rate of cholelith through the combination therapy of oriental and western is needed and deep study on oriental medicine diagnostic and classification according to the observation based on symptoms is necessary.

  • PDF

Ceftriaxone과 연관된 소아의 담도 오니(biliary sludge) 1례 (A Case of Ceftriaxone Associated Biliary Sludge)

  • 윤재균;이현희;신영규;정지태;독고영창
    • Pediatric Infection and Vaccine
    • /
    • 제4권2호
    • /
    • pp.308-313
    • /
    • 1997
  • Ceftriaxone, an effective third generation cephalosporin with a wide range of antimicrobial activity, has become widely used by pediatricians for a variety of bacterial infections including meningitis. It has been associated with the development of sludge or stone in the gallbladder of some patients treated with this drug. Ceftriaxone associated biliary sludge has unusual acoustic characteristics and resembles gallstone. The sludge can cause symptoms such as cramping abdominal pain, and disappears after stopping ceftriaxone administration. Because of these seemingly confusing observations, it is important for the clinicians to recognize these findings that ceftriaxone treatment can cause. We report a case of ceftriaxone associated biliary sludge in Korean children. A 6-year-old girl who was treated for meningitis with ceftriaxone (100mg/kg/day) developed cramping upper abdominal pain from 5th hospital day. Physical examination, liver function tests and X-ray revealed no specific abnormal findings. But abdominal ultrasound revealed high amplitude echogenic sludge with prominent post-acoustic shadow in gallbladder and its diameter was 1.5cm. We stopped ceftriaxone administration and tried conservative care. Abdominal cramping pain subsided after 3 days of ceftriaxone removal. Second abdominal ultrasound confirmed the disappearance of sludge at 3 weeks later.

  • PDF

흉배혈관 천공분지에 기초한 유리피판술의 임상적 이용 (Clinical Experience of Thoracodorsal Perforator Based Free Flap)

  • 남영오;고성훈;어수락
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권2호
    • /
    • pp.105-111
    • /
    • 2005
  • Perforator flaps have become increasingly popular in microsurgery nowadays and are being used widely for many cases of reconstruction after trauma and cancer ablation. And thoracodorsal perforator based free flap is one of them having the merits of carrying a large skin paddle with leaving intact innervation and function of the remaining latissimus dorsi muscle. We made a homogeneous thin flap excluding the main muscle with a long vascular pedicle and tried to decrease the donor site morbidity. But, it needs a long learning-curve and we have met marginal flap necrosis frequently. Besides, prolonged operation time for complete perforator dissection may be a tedious job to the microsurgeon. To overcome these disadvantages, we usually included very small portion of the latissimus dorsi muscle during this flap elevation around the pedicled 2-3 thoracodorsal perforators during this flap elevation. We performed 3 cases of thoracodorsal perforator based free flap at Hallym university sacred heart hospital between May and August 2005 for the soft tissue defect of the scalp and feet. The average flap size was $8{\times}14\;cm$. Although it is not a true perforator flap, we can get the reliability for the flap survival with much better blood circulation and save the time of one or two hours to dissect the perforators completely. All cutaneous flaps survived completely without any complication except one fatty female who had the very small superficial fat necrosis due to flap bulkiness. We believe the thoracodorsal perforator based free flap can be extended its versatility and reliability by including the very small portion of the muscle around the perforators.

  • PDF

Mechanical properties of expanded polystyrene beads stabilized lightweight soil

  • Li, Mingdong;Wen, Kejun;Li, Lin;Tian, Anguo
    • Geomechanics and Engineering
    • /
    • 제13권3호
    • /
    • pp.459-474
    • /
    • 2017
  • To investigate the mechanical properties of Expanded Polystyrene (EPS) Beads Stabilized Lightweight Soil (EBSLS), Laboratory studies were conducted. Totally 20 sets of specimens according to the complete test design were prepared and tested with unconfined compressive test and consolidated drained triaxial test. Results showed that dry density of EBSLS ($0.67-1.62g/cm^3$) decreases dramatically with the increase of EPS beads volumetric content, while increase slightly with the increase of cement content. Unconfined compressive strength (10-2580 kPa) increases dramatically in parabolic relationship with the increase of cement content, while decreases with the increase of EPS beads volumetric content in hyperbolic relationship. Cohesion (31.1-257.5 kPa) increases with the increase of cement content because it is mainly caused by the bonding function of hydration products of cement. The more EPS beads volumetric content is, the less dramatically the increase is, which is a result of the cohesion between hydration products of cement and EPS beads is less than that between hydration products of cement and sand particles. Friction angle ($14.92-47.42^{\circ}$) decreases with the increase of EPS beads volumetric content, which is caused by the smoother surfaces of EPS beads than sand grains. The stress strain curves of EBSLS tend to be more softening with the increase of EPS beads content or the decrease of cement content. The shear contraction of EBSLS increases with the increase of $c_e$ or the decrease of $c_c$. The results provided quantitative relationships between physico-mechanical properties of EBSLS and material proportion, and design process for engineering application of EBSLS.

The Effects of Running Shoes' Midsole Properties on Impact and Lower Extremity Joint's Dynamic Stability

  • Ryu, Sihyun;Gil, Ho-Jong
    • 한국운동역학회지
    • /
    • 제31권4호
    • /
    • pp.290-296
    • /
    • 2021
  • Objective: The purpose of this research is to examine the effects of three types of different running shoes with different properties on impact variables (PVRGF and VLR) and the lower extremity joint's dynamic stability variables (LyEs of DPA, IEA, FEA, DPAV, IEAV, and FEAV) during running. Method: The participants in this research were 12 males (Age: 22.0 ± 3.3 years, Height: 177.2 ± 4.1 cm, Weight: 74.3 ± 9.6 kg). One type of N company's running shoes and two types (FA, FB) of F company's running shoes were used. As for the properties of the running shoes, thickness (mm), dwell time (ms), peak acceleration (m/s2), and energy return (%) were measured. The motions running at 3.5 m/s on a treadmill (Instrumented treadmill, Bertec, USA) wearing each type of running shoes were analyzed. Results: Although the VLR of the thick running shoes (FB) was smaller than that of the other running shoes (N, FA), the LyEs of PVGRF and DPA were larger (p<.05). Even though the running shoes' dwell time (i.e., impact absorption time) and peak acceleration showed a positive correlation with the LyEs of DPAV, IEAV, and FEAV, the energy return showed a negative correlation (p<.05). Conclusion: Our results indicated that the running shoes with excellent impact absorption function are predicted to be suitable for running beginners who need to reduce the burden of the lower extremity joint during running. The running shoes with excellent energy return are expected to be suitable for mid-and long-distance running elite athletes or marathoners to whom stability and consistency are essential during running.

실내실험 및 수치해석을 통한 Carbon Nanotube의 콘크리트슬래브 열전달 효과 검증 (Integrated Experimental-Numerical Approach to Investigate the Heat Transferring Effect of Carbon Nanotube on the Concrete Slab)

  • 김희수;반호기
    • 한국지반환경공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.51-56
    • /
    • 2019
  • 본 연구에서는 염화물, 전열선 등을 이용한 기존 결빙방지기술의 문제점인 도로 및 주변 구조물 내구성 저하, 많은 인력과 유지비용이 필요로 하는 등을 해소하고자 Carbon nanotube(CNT)를 이용한 결빙방지기술에 대한 기초자료로 실내실험과 수치해석 방법을 제시하였다. 이를 위해 실내실험과 수치해석을 통한 검증을 수행하였다. 실내실험은 CNT를 콘크리트 실험체 중심에 1개 삽입 후 냉동 Chamber를 이용하여 주변온도 및 실험체의 내부온도를 $-10^{\circ}C$로 유지하였으며, CNT를 $60^{\circ}C$로 발열시켰다. 콘크리트 표면 온도를 측정하여 발열체로부터 $0^{\circ}C$까지의 거리인 유효발열거리를 확인하였다. 또한 열 중첩에 의한 CNT 간의 간격을 결정하기 위해 CNT를 150, 200, 300mm의 간격으로 삽입하여 총 4가지의 Case로 실내실험을 진행하였다. 실내실험과 함께 콘크리트 실험체의 열전도도 분석을 위한 수치해석을 수행하였다.

Lateral arthroplasty along with buccal fat pad inter-positioning in the management of Sawhney type III temporomandibular joint ankylosis

  • Malhotra, Vijay Laxmy;Singh, Virendra;Rao, JK Dayashankara;Yadav, Sunil;Gupta, Pranav;Shyam, Radhey;Kirti, Shruti
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권3호
    • /
    • pp.129-134
    • /
    • 2019
  • Objectives: The objective of this study was to highlight the role of lateral arthroplasty along with interposition of the buccal fat pad (BFP) in the management of Sawhney type III temporomandibular joint (TMJ) ankylosis. Materials and Methods: Ten patients with TMJ ankylosis (7 unilateral and 3 bilateral, total of 13 joints) were treated with lateral arthroplasty and BFP interposition. The bony bridge of the ankylotic mass on the lateral aspect was resected, leaving a distance of 1.5 to 2.0 cm from the base of the skull to the neck of the condyle. The condyle was left intact. Coronoidectomy was performed on the ipsilateral side via the same approach in all cases. The inter-incisal opening was measured at that time, and if it was less than 35 mm, contralateral coronoidectomy was performed by using the intra-oral approach. After satisfactory inter-incisal mouth opening (${\geq}35mm$) was achieved, the TMJ surgical site was revisited, and BFP was retrieved and used to cover the lateral aspect of the medially placed condyle. Results: With lateral arthroplasty, the medially displaced condyle can be left in-situ to maintain the mandibular ramal height and function and to act as a growth center in children. Interposition of the BFP prevents reformation of the lateral bony bridge that was removed. Conclusion: Lateral arthroplasty along with interpositioning of the BFP is a novel technique for managing Sawhney type III ankylosis that achieves management goals while avoiding complex and advanced reconstructive surgical procedures.