• Title/Summary/Keyword: CM

Search Result 34,861, Processing Time 0.054 seconds

Effects of Planting Density on Growth Characters, Forage Yield and Feed Value of Jeju Native Soybean (제주 재래대두의 재식밀도에 따른 생육형질, 수량 및 사료가치에 미치는 영향)

  • 조남기;강영길;송창길;윤상태;조영일;김동현
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.3
    • /
    • pp.135-142
    • /
    • 2003
  • Jeju native soybean was grown at five plant densities(30${\times}$30cm, 30${\times}$25cm, 30${\times}$20cm, 30${\times}$15cm, 30${\times}$10cm) from May 11 to September 10 in 2002 in Jeju island to determine the optimum plant density. Days to flowering was delayed from 94 days to 98 days as increasing of plant density. Plant height was 103cm at 30${\times}$30cm plot, as plant density increased, was 117cm at 30${\times}$10cm plot. As plant density increased, the number of branches and leaves, stem diameter, weight of plant, root length and weight of root grew low. As plant density increased from 30${\times}$30cm to 30${\times}$15cm, fresh forage, dry matter, crude protein and TDN yield increased 23.3∼36.5MT/ha, 5.1∼8.0MT/ha, 0.8∼1.4MT/ha and 2.9∼4.8MT/ha respectively, but decreased at 30${\times}$10cm plot. As plant density increased, crude protein, crude fat, NFE and TDN content increased 16.2∼17.9%, 2.7∼3.7%, 37.6∼40.7% and 56.1∼60.0% respectively. In contrast with this, crude fiber and crude ash decreased 34.9 ∼30.8% and 8.6∼7.2% respectively. To reach the climax of forage yield was estimated optimum plant density to be 30${\times}$15cm.

A Study on the transition of Explosion to Eire of LPG and Its' Prevention (LP가스 폭발 후 화재 전이 현상 및 전이 방지에 관한 연구)

  • 오규형;이성은
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.20-26
    • /
    • 2004
  • The purpose of this study is to investigate the transition mechanism and prevention mechanism of gas explosion to fire. Transition phenomena of explosion to fire of LPG in the explosion vessel of its size of TEX>$100 cm {\times} 60 cm {\times} 45 cm$ was visualized using the high speed video camera and the mechanism was analysed from the videograph. Newspaper size of $30cm {\times} 20cm$ was used for combustible sample in this experiments and LPG-air mixture was ignited by 10 ㎸ electric spark. Experimental parameter was gas concentration, size of vent area and position of combustible solid. Size of vent area were varied as $10cm {\times} 9cm, 13cm {\times} 10cm, 27cm {\times} 20cm, 40cm {\times} 27cm$, and the position of combustible was varied in 4 point. Carbon dioxide was used to study the prevention mechanism of explosion to fire transition of LPG. Based on this experiment we can find that transition possibility of explosion to fire on solid combustible from explosion is depends on concentration of LPG-air mixture and the exposure time of solid combustibles in high temperature atmosphere of flame and burnt gas. And cooling or inerting of the atmosphere after explosion can be prevent the transition of explosion to fire on solid combustibles from gas explosion.

Effect of Planting Density and a Silicate Fertilizer on Strength of Stem in Chrysanthemum 'Baekma' (국화 'Baekma' 줄기경도에 미치는 재식밀도와 규산질비료 엽면시비 효과)

  • Choi, Seong Youl;Lee, Young Ran;Hur, Eun Joo;Shin, Hak Ki
    • FLOWER RESEARCH JOURNAL
    • /
    • v.17 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • The research was carried out a solution to prevent the breakage of stem resulted from stem cavity in the Dendranthema grandiflorum Ramat. 'Baekma'. Stem cavity occurred in the lower parts of stem for about 5 cm long as the stem grew to 20 cm, and the breakage increased to about 60 cm as the stem grew to 80 cm. Plant height, stem diameter, and flower stalk length were the highest in the planting density of $11cm{\times}11cm$. The light interception by plants increased as the planting density decreased (47, 99 and 143%). The strength and hardness values were the greatest, $567kg{\cdot}cm^{-2}$ and $1,339kg{\cdot}cm^{-2}$ in the planting density of $11cm{\times}11cm$. Plant height and plant weight increased in the foliage fertilization of one time, but the plants in the control flowered earlier. The strength and hardness increased in the foliage fertilization treatments and the greatest in the treatment of one time application of $60mg{\cdot}L^{-1}$ Silicate fertilization. The Si content of stems increased as the fertilization concentration and treatment time increased. The Si content in $30mg{\cdot}L^{-1}$ silicate treated twice was two times as high as that of the control.

A Study on the Development of Ignition Trans applied to Gas Boiler (가스보일러에 적용되는 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Kim, Jang-Won;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.6
    • /
    • pp.467-472
    • /
    • 2021
  • In this paper, the ignition trans used in the gas boiler was produced to measure current, power factor, and power consumption. As a result of measuring the power factor, the self-made ignition trans was higher than that of foreign products and the power consumption was lower. The ignition gap was fixed to 2 m, and when the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 3.45A, 14.5A, and 16.2A. When the ignition gap was fixed to 4mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.8A, 10.1A, and 13.2A. When the ignition gap was fixed at 6mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.73A, 10.2A, and 32.6A. When the ignition gap was fixed at 8 mm and the ignition rod length was 30 cm, 500cm, and 1000cm, it was measured as 3.13A, 9.37A, and 21.4. The ignition gap was fixed at 10 mm, and when the ignition rod length was 30cm, it was measured as 3.4A, 14.4 A, and 25.6A. In conclusion, as the length of the ignition rod increased, the current also increased.

Responses of Castanea crenata to Injection Wound for Oxytetracycline(OTC) (옥시테트라사이크린(OTC) 수간주입 상처에 대한 밤나무의 반응)

  • Cha, Byeong-Jin;Yun, Jeong-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Chestnut(Castanea crenata) were trunk-injected by two methods to check the changes around the injection wound. In September 1993, high concentration of oxytetracycline(OTC) was injected through the injection wound of 1cm diameter and low concentration of OTC through 0.5cm diameter. Trunk diameter of injected trees ranged from 10cm to 20cm. All trees were in their vigorous conditions. Tree reaction was examined in June, 1994. None of them showed any sign of decay by the time. However, under the bark, sapwood was remarkably discolored. But, more severe discoloration was found in 1cm-injection wound than in 0.5cm one. Sapwood of some trees split from the injection wound, and the split was longer in 1cm-injection wounded trees than in 0.5cm trees. From the split, callus grew out and the split was closing. In this kind of trunk injection, the damage was more severe in 1cm-injection wound than in 0.5cm-injection wound.

  • PDF

Diagnostic Analysis and Influential Factors of CM Fee Estimation (CM 대가 산정방식의 문제점 분석에 대한 연구 -문화예술회관 사례를 중심으로-)

  • Yoo, Byeong-Gi;Jung, Chan-Young;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.132-140
    • /
    • 2006
  • On December, 1996, Construction Management(CM) was introduced in Korean construction industry due to its managerial efficiency proven in the international construction industries. However, It have had serious problems with many regulations, standards, manuals and details of practices considering its constituents and industry conditions. Especially, there were controversial points in the CM fee estimate; difference between the fee on the owner's view point and that from contractor's that impedes appropriate CM services. Therefore, this paper is to analyze public construction projects into Cm fee calculation such as fee as a percent of construction cost, cost plus fixed fee and contract price, and analyzed what is irrationality and why irrationality is made. So it makes a contribution to a study on standards for paper CM fee calculation.

A Review of the Improvement of Construction Management (CM) System and the CM Policy for the Public Construction Works (공공사업의 CM제도 개선 및 정책방향)

  • Jang Kie-Chang
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.207-212
    • /
    • 2002
  • The Construction Management(CM) System in Korea is systematized both in name and reality by being prescribed in Construction Industry Act('97) and Construction Management Act('01) through various discussions considering reformation of construction industry structure and enhancement of construction technology competitiveness. Specially in the public construction works, CM Pilot Project is promoted by central government for the activation of CM system introduced for efficiency of public construction project. The promotion of Pilot Project is not only the settlement and activation of CM system but also the process to embody and diversify the CM system. Now we should develop various CM application type such as Owner type, PM type and type for private capital project in doing so. And with this efforts, we could expect that CM system should play an important role to enhance the efficiency of public construction works and should affect private construction sector.

  • PDF

The Temporal Coordination of the Lower Extremity by Increasing High-heel Height during Walking (보행 시 하이힐 굽 높이 증가에 따른 하지의 시간 협응성)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.593-601
    • /
    • 2009
  • The goal of this study was to investigate the lower extremity's coordination determined by temporal relations with increasing high-heel (3, 7, 9cm) while walking on a treadmill. Twelve healthy women who walked on a treadmill under three conditionswearing 3cm high-heel shoes, 7cm, and 9cm-while kinematic data were collected using a six-cameras (240Hz) Qualisys ProReflex System. From these data, knee flexion, tibia internal rotation, and foot eversion were calculated in Euler technique and found the time for occurring the maximum angle of these movements. The maximum angle of these movements occurred almost simultaneously in 3cm high-heel walking, but not in 7cm and 9cm. The ratio of time for maximum angle of the foot eversion to tibia internal rotation converged to 1 in 3cm high-heel walking, but were less than 1 in 7cm and 9cm. In conclusion, it was indicated that 3cm high-heel walking had better the lower extremity's coordination compared with 7, 9cm high-heel walking.

Effects of Row Width and Plant Spacing Within Row on Yield in Scutellaria baicalensis George (재식밀도 차이가 황금의 수량에 미치는 영향)

  • 권병선;신종섭;현규환;신정식
    • Korean Journal of Plant Resources
    • /
    • v.15 no.1
    • /
    • pp.77-80
    • /
    • 2002
  • This study was investigated to find out the optimum planting densities of Scutellaria baicalensis George about growth characters, yield components and yield at 3 planting densities by direct sowing cultivated after barley. Stem length was long in dense planting of 20$\times$l0cm and short in spacious planting of 30$\times$l0cm and 40$\times$10cm by direct sowing cultivated after barley. Stem diameter was thick in spacious planting of 30$\times$10cm and 40$\times$10cm and was thin in dense planting of 20$\times$10cm by direct sowing cultivated after barley. Length and dry weight of root per plant were decreased in dense planting of 20$\times$ 10cm and were increased in spacious planting of 30$\times$10cm and 40$\times$10cm by direct sowing cultivated after barley. Yield of dry root was highest in optimum planting density(30$\times$10cm:33 plants/㎡) by direct sowing cultivated after barley. The correlation coefficient between number of planting plant and stem length showed highly positive correlation. These characters of stem diameter, number of branches, main root length and yield of dry root mentioned above showed negative correlations with planting plants.

Study on skin cold spot distributions of Korean adult (성인남녀의 피부 냉점 분포에 관한 연구)

  • Choi, Jeong-wha;Seol, Hyang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.5
    • /
    • pp.667-671
    • /
    • 1999
  • The purpose of this study was to determine the number of skin cold receptor in Korean adult as a part of the study to investigate thermal physiological characteristics of Korean. For this 10 healthy subjects were placed in a climatic chamber and received cold stimulation of 1$0^{\circ}C$ on skin surface of each measuring site with a thermo-stimulator. As a result of cold spot measurement we found 23 points/cm2 at face 13. points/cm2 at chest 16 points/cm2 at abdomen 11 points/cm2 at back 14 points/cm2 at upper arm 16 points/cm2 at forearm 18 points/cm2 at back of the hand 15 points/cm2 at thigh 8 points/cm2 at leg 12 points/cm2 at dorsum of foot 8 points/cm2 at sole of foot in male subjects and in female subjects we fund 18 points/cm2 at face 13 points/cm2 at forearm 11 points/cm2 at at back of the hand 8 points/cm2 at palm 9 points/cm2 at thigh 6 points/cm2 at leg 8 points/cm2 at dorsum of foot 2 points/cm2 at sole of foot. The distributions of cold spots varied in different regions of the body surface and was exceptionally dense in the facial skin. There were some differences among other researchers' results but the cause of those differences are not yet known those are due to individual or methodological difference.

  • PDF