• Title/Summary/Keyword: CM성과측정

Search Result 193, Processing Time 0.103 seconds

Comparison of clinical techniques to assess objectively accommodative response (타각적 조절 반응 평가의 임상 기술들의 비교)

  • Ryu, Dong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3406-3411
    • /
    • 2010
  • Assessment of the accommodative response is an essential part of the optometric examination. This study measured objectively the accommodation responses those were measured by Autorefractor, MEM retinoscopy and Nott dynamic retinoscopy, and investigate the correlation and difference the results. Twenty-seven college students with normal visual acuity aged 19 to 29 years (mean $22.7{\pm}2.43$ years) participated in this study. Their accommodative responses to accommodative demand of 4D (25cm) were measured with Shin-Nippon NVision-K 5001 Autorefractor, MEM retinoscopy and Nott dynamic retinoscopy. The accommodative responses to accommodative demand of 4D were $3.70{\pm}0.25D$ by Shin-Nippon NVision-K 5001 Autorefractor, $3.58{\pm}0.30D$ by MEM retinoscopy and $3.77{\pm}0.29D$ by Nott dynamic retinoscopy, respectively. There were high correlations among the three techniques (p<0.05). MEM retinoscopy was measured $0.19{\pm}0.13D$ lower than Nott dynamic retinoscopy (p<0.05) and it was measured $0.12{\pm}0.24D$ lower than Shin-Nippon NVision-K 5001 Autorefractor (p<0.05). There was no significant difference between Nott dynamic retinoscopy and Shin-Nippon NVision-K 5001 Autorefractor (p>0.05). MEM retinoscopy showed lesser accommodative responses than Nott dynamic retinoscopy and Shin-Nippon NVision-K 5001 Autorefractor. Author suggest that Nott dynamic retinoscopy may use Shin-Nippon NVision-K 5001 Autorefractor interchangeably to evaluate accommodative responses expect MEM retinoscopy.

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.

RF 플라즈마 아킹의 PM-tube를 이용한 광량 측정

  • Kim, Yong-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.125-126
    • /
    • 2010
  • 플라즈마 아킹은 PECVD, 플라즈마 식각 그리고 토카막과 같은 플라즈마를 이용하는 여러 공정과 연구 분야에서 문제점을 야기시켜왔다. 하지만, 이에 대한 연구는 아킹 현상의 불규칙성과 과도적인 행동으로 인해 미비한 상태이다. 특히, RF 방전에서의 아킹 연구는 DC 방전에서의 아킹 연구에 비해 많이 부족한 것이 현실이다. 플라즈마 아킹은 집단전자방출(collective electron emission)에 의한 스파크 방전(spark discharge)현상이다. 집단전자방출은 전계방출(field emission)이나 플라즈마와 쉬스를 두고 인접한 표면위에서의 유전분극(dielec emission)에 의해 발생한다. 이렇게 방출된 집단 전자들은 쉬스에서 가속되어 에너지를 얻게 되고 원자와의 충돌로 전자 아발란체를 일으킨다. 이렇게 배가된 전자들은 아킹 스트리머(arcing streamer)를 형성하게 되고 아킹 발생 시 높은 전류와 공정 실패의 원인이 된다. 우리는 $30cm{\times}20cm$ 크기의 사각 전극을 위 아래로 가진 챔버에서 Ar 가스를 RF(13.56 MHz)파워를 이용해 방전시켰다. 방전 전압과 전류는 파워 전극 압단에서 High voltage probe (Tektronix P6015A)와 Current probe (TCPA300 + TCP312)를 이용해 측정했다. 플라즈마 아킹시 변하는 플라즈마 플로팅 포텐셜은 챔버 중앙에 위치한 랑뮈프 프로브에 의해 측정되고 챔버 옆의 뷰포트 앞에 위치한 PM-tube를 이용해 아킹시 변하는 광량을 측정한다. RF 방전에서의 플라즈마 아킹은 아킹시 플로팅 포텐셜의 변화에 의해 크게 세부분으로 나눌 수 있다. 아킹 발생과 동시에 급격히 감소하는 감소부분 (약 2us) 그리고 감소한 포텐셜이 유지되는 유지부분 (약 0~10ms) 그리고 감소했던 포텐셜이 서서히 원래 상태로 회복되는 회복부분(약 100 us)이다. 아킹 초기시 방출된 집단 전자들과 원자들간의 충돌에 의해 형성된 아킹 스트리머는 플라즈마 전체를 단락시키게 되고 이로 인해 플로팅 포텐셜은 급격히 감소하게 된다. 이렇게 감소한 플로팅 포텐셜은 아킹 스트리머가 유지되는 한 계속 감소한 상태를 유지하게 된다. 그리고 플라즈마를 섭동했던 아킹 스트리머가 중단되면 플라즈마는 섭동전의 원래 상태로 돌아가려 하기 때문에 플로팅 포텐셜은 서서히 증가하면서 원래 상태로 회복된다. 플라즈마 아킹 발생시 생성되는 아킹 스트리머는 순간적으로 많은 전자들을 국소적으로 생성하게 되고 이 전자들에 의해 광량이 순간적으로 증가하게 된다. PM-tube (750.4 nm)에 의해 측정된 아킹시 광량은 정상방전 상태의 두배 가량이 된다. 그리고 이 순간적으로 증가된 광량은 시간이 지남에 따라 감소하게 되고 정상방전 일때의 광량이 된다. 광량이 증가한 후 정상방전 상태의 광량에 이르는 부분은 플로팅 포텐셜이 감소한 상태에서 유지되는 부분과 일치하고 이는 플로팅 포텐셜의 유지부분동안 아킹 스트리머가 발생하고 있다는 간접적인 증거가 된다. 그리고 정상 방전 상태 일때의 광량이 되면 아킹 스트리머가 중단되었다는 것이므로 그 시점부터 플로팅 포텐셜은 정산 방전상태 일 때의 포텐셜로 복구되기 시작한다. 이처럼 PM-tube를 이용한 아킹 광량 측정은 아킹 스트리머를 간접적으로 측정하게 하고 아킹 스트리머를 이용해 아킹시의 플로팅 포텐셜의 변화를 설명하게 해 준다. 응용적인 측면에서 아킹 광량 측정을 이용한 아킹 판독은 방전 전류와 방전 전압과 같은 전기적 신호를 이용한 아킹 판독에 비해 여러가지 장점을 가진다. 우선, 전기적 신호를 이용한 아킹 판독처럼 매칭 회로나 플라즈마를 섭동시키지 않는다. 그리고 원하는 부분의 아킹만을 판독하는 것도 가능하며 photo-diode를 이용할 경우 전기적 신호를 이용하는 것에 비해 경제적으로 유리하다.

  • PDF

Development of Water Soluble Tocopherol Emulsion Using Surfactants (계면활성제를 이용한 수분산 Tocopherol 유화물의 개발)

  • Lee, Eun-Hyun;Chang, Kyu-Seob;Lee, Kyong-Haeng
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1465-1471
    • /
    • 2008
  • This study was carried out to make water-soluble tocopherol emulsion which can be applicable directly in water. The molecular weight of tocopherol was 340 to 360 and tocopherol emulsion model was decided as O/O/W/W type. In correlation between stability of emulsion and surface tension, the stability in surface tension of emulsion was from 40 to 46 dyne/cm. In the case of lower than 40 dyne/cm of surface tension, the stability of the emulsion was lower. Lipophilic surfactants, especially for a polyglycerine polyricinoleate in 20%, 30% and 40% tocopherol emulsion, was the most effective in emulsion stability. A higher stability of the emulsion among hydrophilic surfactants in the tocopherol emulsion was obtained in the following order; polyglycerine monostearate> polyglycerine monooleate> polyoxyethylene (20) sorbitan monooleate$\geq$ polyoxyethylene (20) sorbitan monolaurate.

Experimental Study on Transient Response According to Variation of Rib Height at Fuel Cell Plate (연료전지용 분리판의 리브 높이 변화에 따른 응답성 변화에 관한 실험적 연구)

  • Nam, Ki Hoon;Yun, Sung Ho;Han, Sung Ho;Choi, Nam Hyeon;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1009-1014
    • /
    • 2013
  • In the present study, using a variation of rib height, the transient response and the performance are investigated. The cell voltage is acquired according to the current density change($0.8A/cm^2$ to $1.0A/cm^2$) under same stoichiometry and relative humidity. The different level of undershoots appeared at the different clamping pressure(1.5MPa and 2.0MPa) and different rib height. At 1.5MPa clamping pressure, rib manufactured cut at $100{\mu}m$ height goes to steady state faster than reference plate and has lower maximum undershoot voltage. But performance is lower than reference plate due to increasing contact resistance.

A Study on the Dielectric Properties and Electrical Conduction of PVDF Thin Films by Physical Vapor Deposition (진공 증착법으로 제작한 PVDF 박막의 유전 특성과 전기전도도에 대한 연구)

  • Gang, Seong-Jun;Lee, Won-Jae;Jang, Dong-Hun;Yun, Yeong-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.9-15
    • /
    • 2000
  • The 3 ${\mu}{\textrm}{m}$-thick PVDF (polyvinylidene fluoride) thin film have been prepared using physical vapor deposition with electric field, and its FT-IR spectrum, dielectric property and electric conduction phenomenon have been investigated. Since the characteristic peaks are detected at 509.45 [$cm^{-1}$ /] and 1273.6 [$cm^{-1}$ /]in the FT-IR spectrum, we are confirmed that the $\beta$ -phase is dominant in the PVDF thin film. In the results of dielectric properties, the PVDF thin film shows anomalous dispersion, i.e. gradual decrease of dielectric constant with increase of frequency, and also that the dielectric absorption point changes from 200 Hz to 7000 Hz with increasing temperature of thin film, which is consistent with the Debye's theory. The activation energy ( $\Delta$H) obtained from temperature dependence of dielectric loss is 21.64 ㎉/mole. We confirm that the electric conduction mechanism of PVDF thin film is dominated by ionic conduction by investigating the dependence of the leakage current of the thin film on the temperature and the electric field.

  • PDF

Distribution of Ultraviolet Intensity and UV Leaking of Commercial UV Sterilizers Used in Restaurants (음식점에서 사용하는 자외선 살균소독기 내 자외선 강도 분포 및 자외선 누출)

  • Mok, Chul-Kyoon;Lee, Nam-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.228-233
    • /
    • 2008
  • Ultraviolet sterilizers (UVS) are widely used in restaurants, cafeterias and catering businesses in Korea. The proper application of UVS, however, is still questionable since no studies have clearly identified their efficacy and safety, while regulations and regulatory management systems are yet to be established. In the present study, the efficacy of UVS were investigated by measuring spatial UV intensity inside five commercially operated UVS. The operating safety parameters were also checked by measuring leaked UV intensity. The UV intensities were inversely proportional to distance from the UV lamp within 25 cm, and to the square of the distance exceeding 25 cm. The UV intensities in commercial UVS varied with the distance from UV lamp and the incident angle, highlighting efficacy and stability concerns. Notable leakage was detected through the door gaps of a studied UVS, which also brought about safety concerns. Allowable working distances for the UV leaking UVS were suggested based on international standards.

Comparative Study on Physical Fitness and Fall Efficacy of Rural and Urban Female Elderly Participants in Continuous Rhythmic Exercise (지속적인 리듬운동에 참여하는 농촌과 도시 거주 노인 여성들의 체력 및 낙상효능감의 비교 연구)

  • Somi, Yun;Eunjin, Hwang
    • Advanced Industrial SCIence
    • /
    • v.1 no.2
    • /
    • pp.17-23
    • /
    • 2022
  • The purpose of this study is to analyze the health factors of the elderly according to the region by analyzing the physical fitness and fall efficacy of the female elderly living in rural and urban areas. The subjects of this study consisted of 98 female elderly people living in rural and urban areas who exercise health and cheerleading at least twice a week at the regional center(REG; n=46, 77.53±6.37 yrs, 151.81±5.26 cm, 60.00±9.42 kg, UEG; n=53, 73.57±2.70 yrs, 154.07±3.52 cm, 57.37±2.06 kg). Physical strength was measured for muscular endurance, cardiopulmonary endurance, and flexibility. Falling efficacy was measured using 10 items of Fall Efficacy Scale developed by Tinetti et al. Significant differences in flexibility and fall efficacy were found in urban older adults (p<.01, p<.05). There was no significant difference in muscular endurance and cardiac endurance (p>.05). In the future, studies to improve the imbalance of health factors of the elderly in the region should be continuously conducted.

Evaluation of Fatigue Endurance on Expansion Joint Manufactured Fe-Mn Damping Alloy (Fe-Mn 제진 금속을 적용한 신축이음장치의 피로 내구성 평가)

  • Kim, Ki-Ik;Kim, Young-Jin;Ahn, Dong-Geun;Kim, Cheol-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.483-489
    • /
    • 2009
  • The endurance of expansion joint manufactured the Fe-Mn damping alloy reducing noise and vibration is analyzed into FEM (Finite Element Method) and fatigue test. The fatigue test have been performed using the expansion joint manufactured Fe-Mn damping alloy and the hydraulic actuator (25tonf). And the results of fatigue test show that the maximum strength is 237.6 MPa. Also that is 56.6 percent of Fe-Mn damping alloy yield strength (420 MPa). The loading plate size is prepared $57.7cm{\times}23.1cm$ and the loading plate's set position is located on expansion joint. The expansion joint manufactured the Fe-Mn damping alloy had not presented breaking behavior against 2,000,000 times fatigue test and identified the fatigue endurance.

Slotted type copper ion laser (Slot형 구리 이온 레이저)

  • 송순달;홍남관
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.291-296
    • /
    • 1997
  • The slotted type of hollow copper cathode was constructed and tested for its geometric stability and usability for laser operation at 780nm. The peak output power of copper ion laser emission was measured for different operating conditions. The IR-laser power was dependent on the parameters of the geometry of the hollow cathodes, discharge current and gas fillings. The peak power decreased with increasing neon pressure over 60%. One reason for this decrease in output power may be conjectured as hier due to the decreasing population of the upper laser level. The copper ion laser transition at 780 nm populated at the 5p level. The hollow cathode copper ion laser is operated in He and Ne mixture by electric discharge excitation and could be operated for more than 100 hours with only a 35% drop in the output power(2.8mW cw for 9.6cm active length).

  • PDF