• Title/Summary/Keyword: CHIP

Search Result 7,329, Processing Time 0.041 seconds

Micro fluxgate magnetic sensor using multi layer PCB process (PCB 다층 적층기술을 이용한 마이크로 플럭스게이트 자기 센서)

  • Choi, Won-Youl;Hwang, Jun-Sik;Choi, Sang-On
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.72-78
    • /
    • 2003
  • To observe the effect of excitation coil pitch on the micro fluxgate magnetic sensor, two sensors are fabricated using multi layer board process and the pitch distance of excitation coil are $260\;{\mu}m$ and $520\;{\mu}m$, respectively. The fluxgate sensor consists of five PCB stack layers including one layer of magnetic core and four layers of excitation and pick-up coils. The center layer as magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ${\sim}100,000$ and has a rectangular-ring shape to minimize the magnetic flux leakage. Four outer layers as excitation and pick-up coils have a planar solenoid structure and are made of copper foil. In case of the fluxgate sensor having the excitation coil pitch of $260\;{\mu}m$, excellent linear response over the range of $-100\;{\mu}T$ to $+100\;{\mu}T$ is obtained with sensitivity of 780 V/T at excitation sine wave of $3V_{p_p}$ and 360 kHz. The chip size of the fabricated sensing element is $7.3\;{\times}\;5.7\;mm^2$. The very low power consumption of ${\sim}8\;mW$ is measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.

Studies on the Gemini Type Amphipathic Surfactant(5) - Preparation and Properties of Double Chain Surfactant with Two Sulfonate Groups Derived from N-Acyldiethanolamines - (제미니형 양친매성 계면활성제에 관한 연구(제5보) - 함질소 장쇄아실디에탄올아민으로부터 유도된 두 개의 술폰산 염기를 갖는 화합물의 합성 및 계면특성 -)

  • Yun, Young-Kyun;Jeong, Hwan-Kyeong;Jeong, Noh-Hee;Nam, Ki-Dae
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.565-568
    • /
    • 1998
  • Amphipathic compounds (bis-sulfonate Gemini type) with double or triple long chain alkyl groups were prepared by the reaction of N-(long chain acyl)diethanolamine diglycidyl ethers with fatty alcohols, followed by the reaction with propanesultone. All these new Gemini type surfactants were soluble in water and showed much better micelle forming ability and lowering surface tension than sodium dodecyl sulfonate with one sulfonate group. cmc and ${\Upsilon}$ cmc values of the triple-chain compounds were still much smaller than those of the corresponding double-chain compounds with two common alkyl groups. The efficiency of adsorption at the water/air interface ($pC_{20}$) of these surfactants was very high. Their foaming properties, wetting ability toward a felt chip, and lime-soap dispersing requirement (LSDR) were measured. Their initial foaming properties were high but showed good low foam stability, wettability and LSDR.

  • PDF

Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods (비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The aim of this study is to develop a label-free immunosensor for microbial detection and to evaluate its applicability to Pseudomonas aeruginosa detection in various food samples. The antibodies used were a polyclonal antiserum from rabbit (polyvalent type) and a monoclonal antibody raised against the flagella of P. aeruginosa. Antibody immobilization was done by a thiolated antibody chemisorption onto one gold electrode of a piezoelectric quartz crystal with a thiol-cleavable, heterobifunctional cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. To the Stomacher-treated samples from various raw and processed foods under cold storage, comprising sirloin, cod and pettitoes, spiking and enrichment culture were done to prepare the model samples, followed by the measurements of the frequency shifts after sample injections. The frequency shifts obtained by the sample matrices themselves were in the range of 52~89 Hz. The injections of the spiked samples caused the frequency shifts of 108~200 Hz, whereas the enriched samples decreased the steady-state resonant frequencies by 162~222 Hz. All sample measurements including baseline stabilization, sample injection and acquisition of the steady-state response were accomplished within 30 min.

LED Source Optimization for the LED Chip Array of the LED Luminaires (LED 조명기구에서 LED 칩 배치에 따른 광원 최적화)

  • Yoon, Seok-Beom;Chang, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.419-424
    • /
    • 2016
  • In this paper, we studied a light distribution for the LED chips arrangement using an optical design software. The structures of the edge type LED luminaires are reflector plane, LGP(lighting guide plane) and diffuse plane. The reflector plane is on the middle of the overall structure. We had simulation that placing LED chips on the reflector center of the reflector edge by changing the position of LED chips above the reflector center at 1mm, 2mm, and 3mm respectively. In the case, when LED chips are on the center of the reflector, it shows the light distribution of the general diffuse illumination, the semi-direct distribution with 0.56 efficiency and the direct distribution with 0.31 efficiency. And the wedge type LGP shows more efficiency than the flat type. Gradually increasing shape of semi-spherical type by 0.015mm has power of 1.02W, efficiency of 0.25, and maximum luminous intensity of 0.104W/sr, it also and shows the better optical characteristics than the reflector plane that have no patterns. This semi-spherical type shows the better optical characteristics than the reflector plane that have no patterns.

Cu Electroplating on the Si Wafer and Reliability Assessment of Low Alpha Solder Bump for 3-D Packaging (3차원 실장용 실리콘 웨이퍼 Cu 전해도금 및 로우알파솔더 범프의 신뢰성 평가)

  • Jung, Do Hyun;Lee, Joon Hyung;Jung, Jae Pil
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.123-123
    • /
    • 2012
  • 최근 연구되고 있는 TSV(Through Silicon Via) 기술은 Si 웨이퍼 상에 직접 전기적 연결 통로인 관통홀을 형성하는 방법으로 칩간 연결거리를 최소화 할 수 있으며, 부피의 감소, 연결부 단축에 따른 빠른 신호 전달을 가능하게 한다. 이러한 TSV 기술은 최근의 초경량화와 고집적화로 대표되는 전자제품의 요구를 만족시킬 수 있는 차세대 실장법으로 기대를 모으고 있다. 한편, 납땜 재료의 주 원료인 주석은 주로 반도체 소자의 제조, 반도체 칩과 기판의 접합 및 플립 칩 (Flip Chip) 제조시의 범프 형성 등 반도체용 배선재료에 널리 사용되고 있다. 최근에는 납의 유해성 때문에 대부분의 전자제품은 무연솔더를 이용하여 제조되고 있지만, 주석을 이용한 반도체 소자가 고밀도화, 고 용량화 및 미세피치(Fine Pitch)화 되고 있기 때문에, 반도체 칩의 근방에 배치된 주석으로부터 많은 알파 방사선이 방출되어 메모리 셀의 정보를 유실시키는 소프트 에러 (Soft Error)가 발생되는 위험이 많아지고 있다. 이로 인해, 반도체 소자 및 납땜 재료의 주 원료인 주석의 고순도화가 요구되고 있으며, 특히 알파 방사선의 방출이 낮은 로우알파솔더 (Low Alpha Solder)가 요구되고 있다. 이에 따라 본 연구는 4인치 실리콘 웨이퍼상에 직경 $60{\mu}m$, 깊이 $120{\mu}m$의 비아홀을 형성하고, 비아 홀 내에 기능 박막증착 및 전해도금을 이용하여 전도성 물질인 Cu를 충전한 후 직경 $80{\mu}m$의 로우알파 Sn-1.0Ag-0.5Cu 솔더를 접합 한 후, 접합부 신뢰성 평가를 수행을 위해 고속 전단시험을 실시하였다. 비아 홀 내 미세구조와 범프의 형상 및 전단시험 후 파괴모드의 분석은 FE-SEM (Field Emission Scanning Electron Microscope)을 이용하여 관찰하였다. 연구 결과 비아의 입구 막힘이나 보이드(Void)와 같은 결함 없이 Cu를 충전하였으며, 고속전단의 경우는 전단 속도가 증가할수록 취성파괴가 증가하는 경향을 보였다. 본 연구를 통하여 전해도금을 이용한 비아 홀 내 Cu의 고속 충전 및 로우알파 솔더 볼의 범프 형성이 가능하였으며, 이로 인한 전자제품의 소프트에러의 감소가 기대된다.

  • PDF

A Bibliometric Analysis on LED Research (계량서지적 기법을 활용한 LED 핵심 주제영역의 연구 동향 분석)

  • Lee, Jae-Yun;Kim, Pan-Jun;Kang, Dae-Shin;Kim, Hee-Jung;Yu, So-Young;Lee, Woo-Hyoung
    • Journal of Information Management
    • /
    • v.42 no.3
    • /
    • pp.1-26
    • /
    • 2011
  • The domain of LED is analyzed for describing the current status of Korea's R&D in the domain comparing with those of others quantitatively. Fourteen sub-domains of LED manufacturing technology are selected and the time span for analysis is ten-year: 2001-2010. Bibiliometric analysis is performed by the unit of publication, core researcher, institution and country. Strategical diagram is also produced with devised two indicators: NGI and NPI. As a result, Korea is competitive in the area of Chip Scale Package, but R&D supports in another promising areas, such as large-caliber sapphire wafer, are necessary. It is also revealed that research activities are expanded dominantly in academia, but practical technologies are developed in industrial circle. It is suggested that to support core corporate and to encourage industrial-academic collaboration is essential for systematical technology development and high achievement in prominent areas.

The Effect of Tomographic Angles on the Osteophytic Lesion Detectability of the Mandibular Condyle (단층촬영 각도의 변화가 하악과두의 골 증식성 병소의 인식에 미치는 영향)

  • Han Sang-Sun;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.309-325
    • /
    • 1999
  • Purpose: To find out the effects that different tomographic angles have on the osteophytic lesion detectability of condyle head by comparison the individualized lateral tomographic image with the various tomographic angled images using SCANORA/sup (R)/. Materials & Methods: This study is performed to simulate osteophytic lesions by a series of dentin chips placed at six locations on condyle head. The control angle is 15° and from this angle. tomographic angle were varied with -10°, +10°, +20°. All the images with each sized dentin chip were scored by three dental radiologists with the use of confidence levels for presence or absence of the lesion, each examiner viewed one of the images twice. A rating scale from 0 to 2 (0, lesion definitely not present; 1. uncertain if lesion is present; 2, lesion definitely present). Responses were assessed by Tukey' s multiple comparison method and kappa value. Results: 1. The lesion size of 0.3 mm could not be detected in all the tomographic angles. As the size of the lesion increased the average value of lesion detectability also increased. 2. In the lesion sizes of 0.7 mm there was statistically significant difference between the 15° control angle and the altered tomographic angles (p<0.05). In 1.0 mm lesion there was no significant difference in the ±10° altered angles (p >0.05). but there was significant difference in the altered angle (p<0.05). In the lesion sizes of 0.3 mm and 2.0 mm there was no significant difference between the 15° control angle and all the altered angles (p >0.05). 3. In the anteromedial. anterosuperior, anterolateral area there was no significant difference between the 15° control angle and the ±10° altered angle (p >0.05), but in the comparison with the +20° altered angle there was significant difference (p<0.05). Conclusion: When imaging the lateral tomography of the temporomandibular joint used by SCANORA/sup (R)/, it can be considered that in the osteophytic lesion size of 2 mm and above, the tomographic angle difference within +20° to the horizontal angle of the condyle. has little effect on the lesion detectability. And in the lesion size of 1 mm, the altered angle within ±10° also has little effect on the lesion detectability.

  • PDF

The study on the capacity of synchronous CDMA return link for a Ka band satellite communication system (Ka 대역을 사용하는 동기화 CDMA 위성 시스템 리턴링크의 수용용량에 관한 연구)

  • 황승훈;이용한;박용서;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1797-1806
    • /
    • 1998
  • Future satellite communication systems will be developed at Ka-band (20/30 GHz) owing to the relatively wide frequency allocation and current freedom from terrestrial interference for multimedia services. A serious disadvantage of the Ka-band, however, is the very high atmospheric attenuation in rainy weather. Synchronous CDMA drastically redces the effect of self-noise with several interesting features of CDMA for mobile communications such as fixible freuqncy rese, the capability of performin soft-handover and a lower sensitivity to interference. This paper evaluates the performance of a synchronous CDMA reture link for a Ka-band geostationary satellite communication system. For a fixed satellite channel whose characteristics depend on weather conditions, the signal envelope and phase for this channel is modelled as Gaussian. The bit error and outage probability, and the detection loss due to imperfect chip timing synchronization is analytically evaluated and the system capacity degaradation due to the weather condition is estimated. The two cases consist of the general case in which all users are affected by rain condition, and the worst case in which the reference user is only affected by rain attenuation. the results for two cases of rain condition clearly show that synchronous CDMA eases the power control requirements and has less sensitivity to imperfect power control.

  • PDF

Design of a Full-Printed NFC Tag Using Silver Nano-Paste and Carbon Ink (은 나노 분말과 카본 잉크를 이용한 완전 인쇄형 NFC 태그 설계)

  • Lee, Sang-hwa;Park, Hyun-ho;Choi, Eun-ju;Yoon, Sun-hong;Hong, Ic-pyo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.716-722
    • /
    • 2017
  • In this paper, a fully printed NFC tag operating at 13.56 MHz was designed and fabricated using silver nano-paste and carbon ink. The proposed NFC tag has a printed coil with an inductance of $2.74{\mu}H$ on a PI film for application to an NFC tag IC with an internal capacitance of 50 pF. Screen printing technology used in this paper has advantages such as large area printing for mass production, low cost and eco-friendly process compared to conventional PCB manufacturing process. The proposed structure consists of a circular coil implemented as a single layer using silver nano-paste and carbon ink, a jumper pattern for chip mounting between the outer edge and the center of the coil, and an insulation pattern between the coil and the jumper pattern. In order to verify the performance of the proposed NFC tag, we performed the measurements of the printing line width, thickness, line resistance, adhesion and environmental reliability, and confirmed the suitability of the NFC tag based on the full-printed manufacturing method.

A Study on the Estimation of Energy Expenditure and falls measurement system for the elderly (고령자를 위한 에너지 소비 추정 및 낙상 측정 시스템에 관한 연구)

  • Lim, Chae-Young;Jeon, Ki-Man;Ko, Kwang-Cheol;Koh, Kwang-Nak;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • As we are turnning into the aged society, accidents by falling down are increasing in the aged people's group. In this paper, we design the system with the 3-Axis acceleration sensor which is composed by a single chip. The body activity signal is measured with the signal detector and RF communicator in this proposed system and the and falling by the entering signal pattern analysis with 3-Axis acceleration sensor. For the RF communication, we are using nRF24L01p and 8bits ATmega uC for the processor. The error of energy expenditure estimation between motor driven treadmill and proposed a body activity module was 7.8% respectively. Human activities and falling is monitored according to analyze and judge the critical value of the Signal Vector. as falled down if they don't turn off the alarm after specific period and the aged person's after falling down activities are their position and more.