• Title/Summary/Keyword: CFD

Search Result 5,741, Processing Time 0.032 seconds

Coal Ash Combustion Simulation for 500-MW Coal-firing Boiler (500MW급 화력발전 보일러의 석탄회 연소 시뮬레이션)

  • Hwang, Min-Young;Jeon, Chung-Hwan;Song, Ju-Hun;Kim, Gyu-Bo;Kim, Seung-Mo;Park, Myung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.939-946
    • /
    • 2011
  • In thermal power generation companies, the recycling of refined ash (LOI < 6%) obtained from a PC-firing furnace is beneficial for the companies, e.g., it can be used for making lightweight aggregates. However, ash having a high LOI, which cannot be reused, is still buried in the ground. To obtain refined ash, the re-burning of high-LOI ash (LOI > 6%) in a PC-firing furnace can be an alternative. In this study, a numerical analysis was performed to demonstrate the effects of ash re-burning. An experimental constant value was decided by TGA (thermo-gravimetric analysis), and a DTF (drop-tube furnace) was used in the experiment for calculating the combustion of ash. On the basis of the trajectory of the moving particles of coal and ash, it was concluded that supplying ash near the burner, which is located high above the ground, is appropriate. On the basis of numerical results, it was concluded that an ash supply rate of 6 ton/h is suitable for combustion, without affecting the PC-firing boiler.

Analysis of the Structural Safety in a Non-heating Greenhouse with a Single Cover for Citrus Cultivation in Jeju (제주지역 감귤재배용 단일피복 무가온하우스의 구조안전성 분석)

  • Yum Sung Hyun;Kim Hak Joo;Chun Hee;Lee Si Young;Kang Yun Im;Kim Young Hyo;Kim Yong Ho
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.166-173
    • /
    • 2005
  • This study was carried out to evaluate the structural stability in a non-heating greenhouse with a single cover for Citrus cultivation which was built up in Jeju on the basis of the drawing designed by Jejudo Agricultural Research & Extension Services and also to make use of the data for developing a standardized non-heating greenhouse in Jeju. The analysis of a structural stability was conducted by using CFX-5.7 and ANSYS under the design condition of a maximum accumulated snow-depth of 19.1 cm as well as an instantaneous maximum wind velocity of $36.6\;m{\cdot}s^{-1}$ which was set up on the basis of meteorological statistics in Jeju. As a result, the maximum von-Mises stress applied on pipes under the wind velocity of $36.6\;m{\cdot}s^{-1}$ showed a value of $250\;N{\cdot}mm^{-2}$ which was greater than the allowable stress of the pipe with a value of $235.4\;N{\cdot}mm^{-2}$ (=$2,400\;kg{\cdot}cm^{-2}$) and also $53.8\;N{\cdot}mm^{-2}$ under the snow-depth of 19.1 cm, respectively. This result suggested that the greenhouse be unstable under the design condition of an instantaneous wind velocity of $36.6\;m{\cdot}s^{-1}$ so that it was necessary for the greenhouse to be reinforced to secure the structural stability.

Optimal arrangement of multiple wind turbines on an offshore wind-wave floating platform for reducing wake effects and maximizing annual energy production (다수 풍력터빈의 후류영향 최소화 및 연간발전량 극대화를 위한 부유식 파력-해상풍력 플랫폼 최적배치)

  • Kim, Jong-Hwa;Jung, Ji-Hyun;Kim, Bum-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.209-215
    • /
    • 2017
  • A large floating offshore wind-wave hybrid power generation system with an area of 150 m2 and four 3 MW class wind turbine generators was installed at each column top. In accordance with the wind turbine arrangement, the wake generated from upstream turbines can adversely affect the power performance and load characteristics of downstream turbines. Therefore, an optimal arrangement design, obtained through a detailed flow analysis focusing on wake interference, is necessary. In this study, to determine the power characteristics and annual energy production (AEP) of individual wind turbines, transient computational fluid dynamics, considering wind velocity variation (8 m/s, 11.7 m/s, 19 m/s, and 25 m/s), was conducted under different platform conditions ($0^{\circ}$, $22.5^{\circ}$, and $45^{\circ}$). The AEP was calculated using a Rayleigh distribution, depending on the wind turbine arrangement. In addition, we suggested an optimal arrangement design to minimize wake losses, based on the AEP.

Study on Methanol Conversion Efficiency of Steam-Methanol Reforming on Pipe Shape and Flow Rate Variation in Curved Channel (수증기-메탄올 개질기의 곡유로 채널형 관 형태 변화에 따른 메탄올 전환율 및 유동 특성에 관한 수치해석적 연구)

  • Seong, Hong Seok;Lee, Chung Ho;Suh, Jeong Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.173-179
    • /
    • 2016
  • This is a numerical study on the curved channel type of hydrogen reformer using the commercial code of fluid dynamics. We numerically compared the numerical model in a previous study model and the modelling of a tube type curved channel. In the result of numerical analysis on 4 types of curved channel reformers, the methanol conversion efficiency of type 1~4 were 45.0%, 45.3%, 45.6%, 45.6% respectively, and there was hardly any difference by ${\pm}0.6%$. In light of flow characteristics, the rectangle type tube and the type 2 with $45^{\circ}$ turn showed most uniform flow characteristics and concentration distribution of methanol, and the circular type tube and the type 3 with $90^{\circ}$ turn had most un-uniform flow characteristics and concentration distribution of methanol. We concluded that the design for curved channel reformer has to have rectangle type tube with curve of almost $45^{\circ}$ as in the type of curved pipe with $45^{\circ}$ turn.

Numerical Study of Turbulent Heat Transfer in Helically Coiled Tubes (나선형 튜브내의 난류 열전달에 대한 수치적 연구)

  • Yoon, Dong-Hyeog;Park, Ju-Yeop;Seul, Kwang-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.783-789
    • /
    • 2012
  • In this study, turbulent flow and heat transfer characteristics in a helically coiled tube have been numerically investigated. Helically coiled tubes are commonly used in heat exchange systems to enhance the heat transfer rate. Accordingly, they have been widely studied experimentally; however, most studies have focused on the pressure drop and heat transfer correlations. The centrifugal force caused by a helical tube increases the wall shear stress and heat transfer rate on the outer side of the helical tube while decreasing those on the inner side of the tube. Therefore, this study quantitatively shows the variation of the local Nusselt number and friction factor along the circumference at the wall of a helical tube by varying the coil diameter and Reynolds number. It is seen that the local heat transfer rate and wall shear stress greatly decrease near the inner side of the tube, which can affect the safety of the tube materials. Moreover, this study verifies the previous experimental correlations for the friction factor and Nusselt number, and it shows that the correlation between the two in a straight tube can be applied to a helical tube. It is expected that the results of this study can be used as important data for the safety evaluation of heat exchangers and steam generators.

Design of Retrieval API to Analyze Web based Simulation Execution Data (웹기반 시뮬레이션 수행 데이터 검색 API 설계)

  • Jung, Young Jin;Seo, Jerry Hyeon;Yu, Jung-Lok;Jin, Du-Seok;Lee, Jun-Hyung;Lee, JongSuk Ruth;Cho, Kumwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.708-710
    • /
    • 2013
  • Web based simulation service is utilized to computationally analyze various phenomena in real world according to the progress of network and computing technology. To provide suitable simulation service, web based simulation service will be improved by analyzing execution data. Especially, an API for data retrieval is designed, because every analyst needs different data. In this paper, we design the retrieval API for a user to analyze the web based simulation execution data, which is used on CFD (Cumputational Fluid Dynamics) and Chemistry. The designed retrieval API provides an simulation execution data depending on an user requirement such as a user type, an execution period, and an affiliation, which is based on the core information such as an user, a simulation program, and a cyberlab. Besides, a developer can provides a suitable information for a user to execute a simulation well such as a simulation statistics, an execution trend, and a frequent error.

  • PDF

Numerical Study for Flow Uniformity in Selective Catalytic Reduction(SCR) Process (SCR 공정에서 반응기 내부의 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4666-4672
    • /
    • 2011
  • Performance of NOx removal in SCR(Selective Catalytic Reduction) process depends on such various factors as catalyst factors (catalyst composition, catalyst form, space velocity, etc.), temperature of exhaust gas, and velocity distribution of exhaust gas. Especially the flow uniformity of gas stream flowing into the catalyst layer is believed to be the most important factor to influence the performance. In this research, the flow characteristics of a SCR process at design stage was simulated, using 3-dimensional numerical analysis method, to confirm the uniformity of the gas stream. In addition, the effects of guide vanes, baffles, and perforated plates on the flow uniformity for the inside and catalyst layer of the reactor were studied in order to optimize the flow uniformity inside the SCR reactor. It was found that the installation of a guide vane at the inlet duct L-tube part and the installation of a baffle at the upper part is very effective in avoiding chaneling inside the reactor. It was also found that additional installation of a perforated plate at the lower part of the potential catalyst layer buffers once more the flow for very uniform distribution of the gas stream.

A Study of Improving Fuel Droplet Movement with Sonic Wave Radiation (음파를 이용한 연료 입자 운동성 향상에 관한 연구)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.608-613
    • /
    • 2019
  • NOx (Nitrogen oxide) in the exhaust gas from vehicle engines is considered one of the most harmful substances in air pollution problems. NOx is made when combustion occurs under high temperature conditions and EGR (exhaust gas recirculation) is normally used to lower the combustion temperature. As the EGR ratio increases, the NOx level becomes low, but a high EGR ratio makes the combustion unstable and causes further air pollution problems, such as CO and unburned hydrocarbon level increase. This study showed that fuel droplets could move more freely by the radiation of sonic wave for the stable combustion. In addition, the engine performance improved with increasing EGR ratio. As a basic study, the effect of sonic wave radiation on the velocity of fuel droplets was studied using CFD software. The results showed that the velocity of small droplets increased more under high frequency sonic wave conditions and the velocity of the large droplets increased at low frequency sonic wave conditions. In addition, an engine analysis model was used to study the effects of the increased combustion stability. These results showed that a 15% increase in EGR ratio in combustion resulted in a 45% decrease in NOx and a 10% increase in thermal efficiency.

A Study on Cooling Condition for Quality Improvement of Rotary Molding Machine (회전성형기의 품질 향상을 위한 냉각 조건에 관한 연구)

  • Kang, Jeong-Seok;Kim, In;Lee, Myungjae;Yoon, Jai-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.367-371
    • /
    • 2019
  • The molding for hollow products used widely in industry is rotational molding by heating and cooling. Uniform cooling is required to improve the quality of the product, and rapid cooling is required to improve the productivity. In this paper, the cooling condition is largely classified into the case of no forced cooling by the fan and forced cooling by the fan. In addition, when forced cooling by the fan is not performed, the condition for stopping the molding machine horizontally and the condition for stopping the molding machine vertically were classified. To confirm the forced cooling by the fan, the conditions were set such that only the molding machine rotates while the fan is not running and the upper and lower fans operate when only the lower fan is operated. The surface temperature of the rotary molding machine was analyzed by the STAR-CCM+ program for the case of air-cooling. The temperature distribution of the rotary molding machine was analyzed for five conditions and the temperature distribution for cooling was compared under each condition. Among the five cases, Case 4 was lowest at approximately 35 ℃ after 900sec.

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.