• Title/Summary/Keyword: CFC11

Search Result 49, Processing Time 0.021 seconds

A Study on the Thermal Decomposition of Carbon Tetrachloride by Pyrolytic Incineration (사염화탄소의 열분해 소각에 관한 연구)

  • 이태호;정홍기
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 1996
  • This study was to decompose carbon tetrachloride and CFC with pyrolytic incineration unit because of prohibition of their usage sooner or later. We have investigated heating value and temperature versus decomposing rate, removal of $Cl_2$ and dust in the flue gas, The results obtained were as follows; 1. In combustion condition to decompose $CCl_4$ heating value was 3,300Kcal/Kg, retention time was 2,0 sec. incinerator exit temperature was $950^{\circ}C$. 2.The removal of HCI and $Cl_2$ in flue gas used NaOH as reagent, then molar ratio o of $Na^+/Cl^-$ was 1.07. 3. NaCI of dust component was more than 90 %, 2 stage venturi scrubber was used to remove dust, then removal rate of dust was 99% over at L/G of $1.7Vm^3$

  • PDF

Effects of Air Flow Nonuniformity on the Thermal Performance of a Compact Evaporator for Natural Working Fluids (밀집형 자연냉매 증발기의 열성능에 미치는 불균일 공기유동분포의 영향)

  • 박병규;김근오;김무근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1114-1124
    • /
    • 2001
  • The application of carbon dioxide as an attractive natural working fluid in air cooling and heating system is increasingly important in view of the CFC substitution problem. The thermal performance of compact evaporator was analyzed using section-by-section method. The effects of the two-dimensional nonuniformity of air flow through the evaporator is presented. The detrimental effect of the aid flaw nonuniformity on the thermal performance of the evaporator is found to be significant for many typical applications. It is shown that total heat transfer rate of evaporator using $CO_2$ is higher than that using R134a at the simulation conditions.

  • PDF

A Design of the Block Type Expansion Valve in Automotive Air Conditioning System using HFC-134a (신냉매용 자동차 공조 시스템에서 블록식 팽창밸브의 설계)

  • Kim, K.H.;Park, S.H.;Kang, W.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.196-203
    • /
    • 2003
  • This study was performed to design the optimal block type expansion valve through analyzing the characteristics of the block type expansion valve in automotive air conditioning system using HFC-134a. Because an alternative refrigerant (HFC-l34a) is being used instead of CFC-12 for automotive air conditioning system, newly designed air conditioning components are necessary due to changes in characteristics. The performance tests were accomplished through the test bench, that is manufactured based on the study. And then it was carried out to measure the variation of temperature and pressure at each part of the air conditioning system according to the compressor speed.

Performance and heat transfer characteristics of refrigeration system using R-502 alternatives (R-502의 대체냉매를 사용한 냉동시스템의 성능 및 열전달 특성)

  • 박창대;김민수;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.624-632
    • /
    • 1999
  • In order to replace CFC-502 which has been widely used in transportation and low temperature refrigeration system, performance tests using HFC-407A, HFC-404A and HFC-507 have been carried out. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$and $54.5^{\circ}C$ for each refrigerant. System performance characteristics and heat transfer characteristics of each refrigerant were obtained at several compressor speeds and evaporating temperatures ranging from$-25^{\circ}C$ to $-10^{\circ}C$ Test results show that the use of tested alternative refrigerants without changing system components offers the potential performance improvement of a refrigeration system.

  • PDF

Design of Incremental Model by Linear Regression and Local RBFNs (선형회귀와 국부적인 RBFN에 의한 점진적인 모델의 설계)

  • Lee, Myung-Won;Kwak, Keun-Chang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.471-473
    • /
    • 2010
  • 본 논문은 선형회귀(LR: Linear Regression)와 국부적인 방사기저함수 네트워크(RBFN: Radial Basis Function Networks)를 결합한 점진적인 모델(incremental model)의 설계와 관련되어진다. 전형적인 RBFN에 의한 모델링과는 달리, 제안된 방법의 근본적인 원리는 두 단계에 의해 고려되어진다. 첫째, 전체 모델의 설계과정에서 전역적인 모델로써 선형회귀에 의해 데이터의 선형부분을 구축한다. 다음으로, 모델링 오차는 오차가 존재하는 국부적인 공간에서 RBFN에 의해 보상되어진다. 여기서, 오차의 분포로부터 RBFN을 설계하기 위해 컨텍스트 기반 퍼지 클러스터링(CFC: Context-based Fuzzy Clustering)를 통해 정보입자의 형태로 구축되어진다. 실험은 자동차 mpg 연료소비량 예측과 부동산 가격예측문제를 통해 제안된 방법의 우수성을 증명한다.

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • 이종선
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.68-78
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • Jo, Dong Hyeon;Lee, Jong Seon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.65-65
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32℃ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

The Development of Korean Life Cycle Impact Assessment Index Based on a Damage Oriented Modeling (한국형 피해산정형 전과정 영향평가 지표 개발)

  • Park, Pil-Ju;Kim, Mann-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.499-508
    • /
    • 2010
  • This study proposed a life cycle impact assessment index that can indicate the environment-related information of the product in monetary value such that the national geographical, environmental, and social features are fully reflected based on a damage-oriented model. First, the estimation process was classified into characterization, damage assessment, and integration stages considering the six biggest impact categories: resource depletion, global warming, ozone depletion, acidification, eutrophication, and photochemical oxidant creation. Moreover, this study came up with the 16 category endpoints related to the 6 impact categories, and the damage function, to the 4 largest safeguard subjects. The integration indices of finally identified impact categories were KRW 21.8/kg Sb, KRW 6.19/kg$CO_2$, KRW 53,000/kg CFC-11, KRW 13,100/kg $SO_2$, KRW 2,310/kg ${PO_4}^{3-}$, and KRW 3,030/kg $C_2H_4$. Using the results of this research, environmental impacts based on the environmental load generated throughout the entire life cycle of a product can serve as a single index in monetary value; thus enhancing understanding and utilization of the results of life cycle impact assessments.

Life Cycle Assessment(LCA) of Rubber Recycling Process in Waste Tire (폐타이어 고무 재활용 공정의 전과정평가 연구)

  • Ahn, Joong Woo;Kim, Jin Kuk
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.74-83
    • /
    • 2018
  • This study conducted the Life Cycle Assessment(LCA) on waste rubber recycling technology for recovering rubber product from the waste tires. Environmental impacts were assessed for the five categories of impacts: global warming, resource depletion, acidification, eutrophication, photochemical oxide production, and ozone layer depletion. When recycling 1ton of waste tire containing rubber, global warming impact was 1.77E+02 kg $CO_2-eq.$, resource depletion impact was 1.23E+00 kg Sb-eq., acidification impact was 5.92E-01 kg $SO_2-eq.$, eutrophication impact was 1.23E-01 kg $PO{_4}^{3-}-eq.$, photochemical oxide production impact was 3.42E-01 kg $C_2H_4-eq.$, and ozone layer depletion impact was 1.87E-04 kg CFC11-eq. In terms of overall environmental impacts, carbon, softener and electricity the greatest impact, so it is necessary to compare the environmental impacts of the raw materials to replace carbon and softener, and a method to reduce the filler usage in the process is needed. In addition, it is necessary to improve energy efficiency, change to low-energy sources, and apply renewable energy.

Unprovoked seizures in children with complex febrile convulsion; short-term outcome (복합 열성 경련 후 간질 발생 환아의 임상적 고찰; 단기 추적 관찰 결과)

  • Choi, Ji Yeon;Cheon, Eun Jung;Lee, Young Hyuk
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.8
    • /
    • pp.757-760
    • /
    • 2007
  • Purpose : Febrile convulsions (FC) were considered to be a benign seizure syndrome that is distinct from epilepsy. But it is thought that children with complex features i.e., partial or prolonged seizures or multiple episodes of FC would bear a higher risk of developing unprovoked seizures. The aim of this study is to look into the relative significance of each criteria that define complex febrile convulsions (CFC) as a predictor of subsequent epilepsy. Methods : All children were retrospectively identified for a febrile seizure through pediatric departments of the Konyang University Hospital. Information was collected from medical records and interviews with parents. Patients with abnormal neurological examinations at presentation were excluded. Results : This study was performed from March 2000 to December 2003. Sixty-three out of 314 children (20.0%) with febrile convulsion fulfilled the criteria for CFC and forty-four children of them have been followed for 12 months or more. Ten of these (23.2%) had unprovoked seizures for 14-62 months (median $34.2{\pm}11.6$ months). The patients with partial FC showed a trend toward a higher risk (57.1%) of developing epilepsy than the patients with multiple or prolonged febrile convulsions (26.7%, 24.1% respectively). Conclusion : We found that the partial feature of febrile convulsion is associated with subsequent epilepsy.