신냉매용 자동차 공조 시스템에서 블록식 팽창밸브의 설계

A Design of the Block Type Expansion Valve in Automotive Air Conditioning System using HFC-134a

  • 김경훈 (경희대학교 기계ㆍ산업시스템공학부) ;
  • 박상훈 (자동차부품연구원) ;
  • 강우 (자동차부품연구원)
  • Kim, K.H. (College of Advanced Technology Kyung Hee University) ;
  • Park, S.H. (KATECH(Korea Automotive Technology Institute)) ;
  • Kang, W. (KATECH(Korea Automotive Technology Institute))
  • 발행 : 2003.07.01

초록

This study was performed to design the optimal block type expansion valve through analyzing the characteristics of the block type expansion valve in automotive air conditioning system using HFC-134a. Because an alternative refrigerant (HFC-l34a) is being used instead of CFC-12 for automotive air conditioning system, newly designed air conditioning components are necessary due to changes in characteristics. The performance tests were accomplished through the test bench, that is manufactured based on the study. And then it was carried out to measure the variation of temperature and pressure at each part of the air conditioning system according to the compressor speed.

키워드

참고문헌

  1. SAE 97010 Development of Sub-Cool System Y.Yamanaka;H.Matsuo;K.Tuzuki;T.Tsuboko
  2. Int. J. Thermophys v.10 no.3 Thermo-physical Properties of 1,1,1,2-Tetrafluoroethane(R-134a) R.S.Basu;D.P.Wilson https://doi.org/10.1007/BF00507981
  3. ASHRAE Transactions v.97 Thermodynamic Charts, Table and Equations for Refrigerant HFC-134a A.Kamei;C.Piao;H.Sato;K.Watanable
  4. SAE 910218 Performance Evaluation of an Automotive Air Conditioner with Expansion Valve Control Using CFC-12 & HFC-134a Refrigerants R. EI-Bourini;K.Hayashi;T.Adashi
  5. SAE 900214 Automotive Air Conditioning System Performance with HFC-134a Refrigerant R. EI-Bourini;T.Adachi;K.Tajima
  6. SAE 870029 Improvement of Refrigerant Flow Control Method in Automotive Air Conditioners M.Mitsui
  7. Journal of KSAE v.16 no.2 The State of the Automotive Air-Conditioning Systems Using HFC-134a Y.G.Song
  8. J of Mitsubishi Heavy Co. v.28 no.2 Study on Automotive Air Conditioner System to Cope with CFCs Regulations K.Gano;L.A.Guntly;N.F.Costello
  9. N.A.C.A. no.369 Effect of Orifice Length-Diameter Ratio on the Coefficient of Discharge of Fuel-Injection Nozzles A.G.Gelalles;G.T.Marsh
  10. Proceeding of ILASS-Korea 2nd Asian Conference A Design of the Block Type Expansion Valve in Automotive Air Conditining System S.H.Lee;K.H.Kim;Y.G.Song
  11. Transactions of KSAE v.4 no.6 Optimum Design Scheme of Receiver Dryer in an Automotive Air-Conditioning System using HFC-134a Refrigerant Y.H.Song;K.H.Kim;Y.G.Song
  12. Fluent 5 User's Guide
  13. 1998 KSAE Spring Conference Proceeding A Design of the Block Type Expansion Valve in Automotive Air Conditioning System using HFC-134a S.H.Lee;K.H.Kim;S.H.Park;W.Kang
  14. KATECH-NR 0691-97 Development of Expansion Valve and Receiver Dryer in a Automotive Air-Conditioning System using HFC-134a Refrigerant Y.H.Song;K.H.Kim;S.H.Park;H.W.Rho;W.Kang