• Title/Summary/Keyword: CFC11

Search Result 49, Processing Time 0.022 seconds

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.

Physical Properties of Rigid Polyurethane Foams Prepared by Co-Blowing Agents (Co-blowing agent에 따른 경질 폴리우레탄 폼의 물성 변화 연구)

  • Kim Sang Bum;Koh Sung Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.1-7
    • /
    • 2004
  • The physical properties of rigid polyurethane foam(PUF) synthesized using various types of blowing agents such as water, HFC-365mfc, HFC-245fa, HCFC-l4lb, CFC-11 and n-pentane were studied. The blending effect of blowing agents were also studied. The thermal conductivity, reaction rate, and cell morphology of the PUF with various blending ratio of blowing agents were investigated. The PUF blown by water shows the highest compressive strength among other single blowing agents. The thermal conductivity of PUFs blown by HFC-245fa and HFC-365mfc are close to that of PUFs blown by CFC-11. When HFC-365mfc was mixed with HFC-245fa(30mo1e$\%$) as coblowing agent, the mechanical property shows the highest value among other coblowing agents. It is that the thermal conductivity of PUFs depends on cell size of PUFs as well as thermal conductivity of blowing agent in gaseous form.

  • PDF

A Study on the Fluorination of Pentachloroethane (Pentachloroethane의 불소화 반응에 관한 연구)

  • Park, Kun-You;Kwon, Young-Soo;Kim, Hoon-Sik;Lee, Sang-Deuk;Lee, Byung-Gwon
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.318-323
    • /
    • 1993
  • Pentachloroethane($CHCl_2CCl_3$) was synthesized and reacted with hydrogen fluoride using antimony pentahalide catalyst($SbCl_xF_y$) in order to manufacture HCFC-123$(CF_3CHCl_2)$, a potential CFC-11$(CFCl_3$) substitute candidate. Products analyses showed the fluorination proceeds through fluorine-chlorine exchanges between $HF/SbCl_xF_y$ and $SbCl_xF_y/CCl_3CHCl_2$ respectively. The degree of fluorination of $CCl_3$ group in pentachloroethane was greatly affected on the reaction temperature, but the effect of catalyst concentration was relatively small. Mechanistic study was also performed to elucidate the pathway to the formation of side-products such as $CCl_3CFCl_2$, $CFCl_2CFCl_2$ and $CF_2ClCFCl_2$.

  • PDF

Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube (HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

A Study on the Decomposition of CFC-113 by Catalyst (CFC-113의 촉매분해에 관한 연구)

  • 李宇根;平岡正勝
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.131-136
    • /
    • 1995
  • The experiment for decomposing CFF-113 by a honeycomb catalyst was carried out in this study. Benzene and water were used as decomposing agents. The reaction of decomposition was from 600 .deg.C to 900.deg.C. Benzene was injected at 900.deg.C and then the catalyst was heated to 1100.deg.C by the heat of combustion of it. The electric power of the reactor was turned off when the combustion was started. The reaction temperature, however, was main trained and the decomposition of CFC-113 continued at that time. It was found that the highest decomposition efficiency was 80% at the ratio of benzene/CFC-113 of 20/1 in this experiment.

  • PDF

A Study on the condensate Retention at Horizontal Integral-Fin tubes (낮은 핀을 가진 수평관의 응축액 억류에 관한 연구)

  • 한규일;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.151-165
    • /
    • 1996
  • Relation between condensate retention and heat transfer performance is studied for condensation of CFC-11 on horizontal integral-fin tubes. Eight tubes with trapezoidally shaped integral fin density from 738fpm to 1654fpm and 10, 30 grooves are tested. The liquid retention angles are measured by the height gauge, and each tube is tested under static(non-condensing) condition (CFC-11, water) and under dynamic(condensing) condition (CFC-11). The analytical model predicts the amount of liquid retention on a horizontal integral-fin tubes within+10 percent over most of the data. Average retention angle increases as both surface tension-to-density ratio($\sigma/\rho$) and fin density(fpm) increase, The tube having a fin density of 1299~1654fpm has the best heat transfer performance. The amount of surface flooding must keep below of 40 percent for best heat transfer performance at condensation. The tube having low number of fin density must be used for fluids having high values of $\sigma/\rho$(water, (TEX)$NH_3$, ect.) and the tube having high number of fin density must be used for the fluid having low values of $\sigma/\rho$(R-11, R-22, etc.)

  • PDF

A Dscussion for the Performance Improvement of Actual Regregeration Compressors (실용 냉동압축기의 성능향상 고찰)

  • 유동수;신승훈
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.979-984
    • /
    • 1993
  • 압축기는 냉동 . 공조 사이클에서 냉매를 압축하여 순환시키는 기능을 한다. 냉동 . 공조 사이클 에서 압축기의 효율 COP는 압축기 모터 입력에 대한 증발기에서의 냉각 능력의 비로서 정의 된다. 따라서 압축기 자체의 특성도 중요하지만 냉매의 열역학적 물성도 중요한 역할을 한다. 압축기의 효율향상문제가 최근에 대두되게 된 것은 첫 째, 몬트리올 협정에 의해 CFC의 사용이 제한되면서 새로 검토하게 된 대체냉매들의 열물성이 CFC보다 불리한 점과 둘째, 에너지 소비를 줄이려는 인식이 환경 측면에서 확산되고 있기 때문이다. 이 글에서는 압축기 효율을 결정하는 주요요소에 대하여 알아보고 최근 국내외에서 이루어지고 있는 효율향상 성과에 대하여 소개하 기로 한다.

  • PDF

Effect of the polyols and blowing agents on properties of rigid polyurethane foam (폴리올과 발포제에 따른 경질 폴리우레탄 폼의 물성 변화 연구)

  • Kim S. B.;Son Y. J.;Kim Y H.;Lee Y B.;Choi S. H.;Choe K. H.;Kim W. N.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.79-84
    • /
    • 2001
  • In this study, the effect of polyol structure(OH-value, functionality) on the reactivity, mechanical property and cell morphology of polyurethane foam and the possibility of replacing HFC-36smfc was examined by evaluating how each blowing agent(CFC-11, HCFC-l4lb, HFC-36smfc) affects the reactivity, mechanical property and cell morphology. Results of the experiment showed that as the functionality and OH-value of polyol increased, there was an increase in the temperature profile, reaction rate, density and compressive strength. However. as the functionality and OH-value increased. the ceil size became smaller The use of different kinds of blowing agents did not appear to have and significant influence on the temperature profile, reaction rate, density and compressive strength. The foam using HFC-365mfc produced more uniform cells compared to the foam using HCFC-l4lb.

  • PDF