• Title/Summary/Keyword: CFC

Search Result 271, Processing Time 0.024 seconds

A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22 (R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교)

  • Pak, H.Y.;Park, K.W.;Park, Y.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

A Study of Performance Improvement of CFCS SW Using HPC (HPC를 활용한 지휘무장통제체계 SW 성능향상 연구)

  • Baek, Chi-Sun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.1-2
    • /
    • 2017
  • 본 논문에서는 지휘무장통제체계(이하 CFCS) 소프트웨어의 성능 향상 기법으로 고성능 컴퓨팅(이하 HPC) 시스템 활용 기법을 제안한다. 이 기법으로 본 논문에서는 HPC 분야인 멀티코어 프로세서를 활용하는 방법을 제안한다. 복잡한 반복연산을 하는 작업이 많은 CFCS의 특정 SW모듈에 대해 멀티코어 프로세싱 아키텍처를 이용한 병렬처리를 적용하여 기존 순차처리 대비 작업실행시간을 단축함으로써 작업 응답시간을 상당히 줄일 수 있다. 본 논문에서는 CFCS 시험 환경의 일부 특정 SW모듈 상에서 기존의 순차처리 방식으로 수행한 연산 결과와 다중 처리 프로그래밍 API인 OpenMP를 적용하여 수행한 연산 결과를 비교하여 CFCS에서의 멀티코어 프로세싱이 체계 전반의 성능 향상 면에서 효율적으로 사용될 수 있음을 보인다.

  • PDF

The Theoretical Investigation on the Stability of Solid/Liquid Dispersion (고/액간 계면에 있어서 분산의 안정성에 관한 이론적 고찰)

  • Kim, Tae-Young;Cho, Kyoung-Haeng;Nam, Kie-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1995
  • In this outline, the stability of solid/liquid dispersion was theoretically investigated the matter from all angles by using the modified DLVO theory. The stability was handled various considerations such as a production and characteristics of electrical double layer, total interaction$(V_T)$ that consisting of attractive force$(V_A)$ and repulsion$(V_R)$. coagulation, the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ etc. It was possible for us to examine with the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ that may estimation of stability of solid/liquid dispersion experimentally.

The Study on Performance Characteristics of Superheating the Suction Vapor in $NH_3$ Refrigeration System ($NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구)

  • 권일욱;하옥남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.756-761
    • /
    • 2004
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the NH$_3$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 14.5 bar to 16.0 bar by 0.5 bar and for superheat temperature from $0^{\circ}C$ to 1$0^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

Performance Simulation for the Optimal Design of Automotive Air-Conditioning System (자동차용 냉방시스템의 최적설계를 위한 성능시뮬레이션)

  • 김제봉;신기열;김수연;정평석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.570-580
    • /
    • 2000
  • The performance simulation of refrigeration system for the automotive vehicles was peformed, in which the refrigerant was HFC-l34a as an alternative to CFC-12. The coefficient of performance of the system for HFC-l34a was lower than that for CFC-12 operated in the same operating and design conditions. The optimal design conditions were obtained as a function of optimum capacity ratios of condenser and evaporator.

  • PDF

$CO_2$ 냉매용 가스쿨러의 열전달 특성

  • 장영근;강병하
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.7
    • /
    • pp.24-28
    • /
    • 2002
  • 1987년의 몬트리얼 의정서에 의한 CFCs와 HCFCs의 규제에 이어 1999년의 교토의정서에 의한 지구온난화 물질에 대한 규제는 CFCs와 HCFCs의 대체물질로 준비되어온 HFCs의 사용에 제동을 걸게 되었다. 아울러 환경론자들은 냉동공조 업계가 HFCs를 사용하지 말고 탄화수소, 이산 화탄소, 암모니아, 물 및 공기와 같은 보다 환경친 화적인 자연냉매를 사용할 것을 요구하고 있으며, 최근 학계의 자연냉매에 대한 고무적인 연구결과는 자연냉매의 사용에 대한 산업계의 관심을 고조 시키고 있다. 본 고에서는 최근 주목을 받고있는 이 산화탄소를 냉매로 하는 냉방시스템 중의 한 요소인 가스쿨러에 대한 연구개발 현황분석 및 향후 과제에 대하여 살펴보기로 한다.