• 제목/요약/키워드: CD test

검색결과 619건 처리시간 0.021초

흰쥐 조직에서의 카드뮴 결합 고분자량 단백질 [Cd-BP(II)]의 유도 (Induction of Cd-binding High Molecular Weight Protein [Cd-BP(II)] in Rat Tissues)

  • 천기정;김봉희
    • 약학회지
    • /
    • 제43권5호
    • /
    • pp.591-597
    • /
    • 1999
  • The study was carried out on the biochemical characters of Cd-BP(II) after isolation and purification of the protein from the liver of rat ip injection with Cd. A continued study has been doing whether Cd-BP(II) could be induced by Cd or by the other metals such as Zn and Cu. Antisera were made against the antigen of Cd-BP(II) from New Zealand white rabbits. We carried out g-globulin purification, then Ouchterlony test and gel immunodiffusion test. Cd-BP(II) was also found in normal tissues of rat. It was induced up to a considerable level by Cd, whose induced level was higher than that Cu or Zn treatment. The level of induction by Cu or Zn pretreatment plus Cd treatment was lower than that by single treatment of Cu or Zn. Such a result was presumably related to the Cd toxicity.

  • PDF

흰쥐 조직에서의 카드뮴 결합 고분자량 단백질의 유도 (Induction of Cd-binding High Molecular Weight Protein in Rat Tissues)

  • 천기정;김봉희
    • 약학회지
    • /
    • 제41권3호
    • /
    • pp.352-358
    • /
    • 1997
  • The study was carried out on the biochemical characters of Cd-BP(I) after isolation and purification of the protein from the liver of rat injected intraperitoneally with Cd. A c ontinued study has been doing whether Cd-BP(I) could be induced by Cd or by other metals such as Zn and Cu. Antisera were made against the Cd-BP(I) from NewZealand white rabbits. Carried out were ${\gamma}$-globulin purification, then Ouchterlony test adn gel immunodiffusion test. Cd-BP(I) was also found in normal tissues of rat. It was induced up to a considerable level by Cd, whose induced level was higher than that of Cu or Zn treatment. The level of induction by Cu or Zn pretreatment plus Cd treatment was lower than that by simple treatment of Cu or Zn. Such a result was presumably related to the Cd toxicity.

  • PDF

형광 영상 기반 CD4 신속 검사법 개발을 위한 항원-항체 반응 조건 정량화 (Quantitation of Antigen-Antibody Reaction Condition for Development of Fluorescence Image-based CD4 Rapid Test)

  • 김수빈;김중경
    • 한국가시화정보학회지
    • /
    • 제13권1호
    • /
    • pp.35-42
    • /
    • 2015
  • CD4+ T-cell count determines the effectiveness for antiretroviral therapy (ART) in patients with human immunodeficiency virus (HIV). Although ART slows the progression of HIV to AIDS, rapid counting of CD4+ T lymphocytes with a drop of patient's blood sample is urgently needed to ensure timely ART treatment in rural areas. Recently point-of-care CD4 testing devices have been developed by using non-flow based imaging cytometer incorporated with a sample cartridge where CD4+ T cells are reacted with fluorescently tagged specific antibodies. Here we conducted an experimental study using a conventional fluorescence microscope-based imaging system to quantitate the interaction of CD4 antibodies with CD4+ T cells at different reaction conditions. We demonstrated that a fast and affordable point-of-care CD4 test is feasible with a far less amount of antibodies and a shorter incubation time compared with a conventional sample preparation protocol for flow cytometry. We also proposed a general method to evaluate and compare the detection limit across different CD4 counting platforms by using fluorescently labelled microbeads for intensity calibration.

CD-RW Drive의 낙하충격 손상평가 (Damage Evaluation of CD-RW Drive by Drop Test and Simulation)

  • 우재철;윤기원;석기영;김헌영;김상범
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.

Perception on the Traditional Korean Medicine According to the Existence of a Chronic Disease

  • Kim, Jihye;Park, Minjung;Sung, Angela Dong-Min;Kim, Kyeong Han;Sung, Soo-Hyun
    • 대한약침학회지
    • /
    • 제23권4호
    • /
    • pp.252-261
    • /
    • 2020
  • Objectives: Chronic diseases (CDs) continue to increase due to advances in medicine and increase in lifespan, affecting quality of life and resulting in economic loss through treatment costs. This study addressed the perception characteristics of the effectiveness of Korean medicine (KM) based on the existence of a CD to determine the national preference for KM treatment. Methods: Using data from the 2017 National Survey of KM Usage, we evaluated the perception on treatment effect of 16 diseases by dividing them into the CD group and the non-CD group. Response reliability was verified by applying the chi-square test (χ2-test) analysis method of the Statistical Package for the Social Sciences (SPSS) statistical program. Results: The analysis of the perception on effectiveness of KM for patients with CD (n = 1,050, 21.0%) and for patients with non-CD (n = 3,950, 79.0%) showed an overall similar trend for all the 16 diseases. The response rates of having some treatment effect were high for nine diseases namely, disc-related disease (CD: 70.7%, non-CD: 73.1%), osteoarthritis (CD: 72.3%, non-CD: 72.4%), frozen shoulder and shoulder pain (CD: 79.6%, non-CD: 81.4%), back pain (CD: 84.6%, non-CD: 85.0%), sprain (CD: 84.8%, non-CD: 84.1%), facial nerve paralysis (CD: 73.5%, non-CD: 71.7%), stroke (CD: 66.2%, non-CD: 62.8%), digestive disease (CD: 53.3%, non-CD: 50.0%), and common cold and rhinitis (CD: 44.7%, non-CD: 44.8%). Conclusion: The present results found that there was little difference in the perception on effectiveness of KM for each of the 16 diseases in patients with CD and non-CD, however, 70% or more of the respondents recognized some treatment effect on musculoskeletal disorders, regardless of the existence of CD. Preferential political support for KM treatment of chronic musculoskeletal disorders is recommended.

니켈카드뮴 축전지의 성능시험 분석 (An Analysis of Performance Test Results for Nickel-Cadmium Battery)

  • 온정근;김명룡;김원경;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.600-605
    • /
    • 2003
  • Battery of rolling stock is a very important device as power supply at starting and emergency control. This paper analyzes the quality of Ni-Cd battery by means of performance test. Ni-Cd battery have suitable and stable properties. That is very stable to discharge on low temperature state and very easy to manage and repair. This paper confirm the performance and property of Ni-Cd battery on low temperature environment by the performance test and estimate the life-cycle of Ni-Cd battery on board at rolling-stock by the life-test and the using-test.

  • PDF

주택매매 및 전세지수와 CD금리, 가산금리 간의 인과관계 분석 (An Analysis on the Casual Relationship among Housing Transaction Index, Jeonse Rental Index, CD Interest Rate and Spread)

  • 김은성;이상효;김재준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.265-268
    • /
    • 2009
  • The purpose of this study is to analyze the casual relationship among Housing Transaction Index, Jeonse Rental Index and Interest Rate. To analyze the influence of interest rate in more detail, CD Interest rate and Spread are used as variables. Granger Casualty Test is used as a analysis tool, As a result, Spread is the cause variable of the Housing Transaction Index and the Housing Transaction Index is the cause variable of the CD Interest Rate. And also, CD Interest rate influences the Jeonse Rental Index and the Jeonse Rental Index has influence on the other variables.

  • PDF

Weil-Dobke 합성단락시험로의 최적화 연구 (A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests)

  • 김맹현;고희석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

Al-Cu-Mn주조합금의 SCC특성에 미치는 Cd첨가의 영향 (Effect of Cd Addition on the SCC Properties of Al-Cu-Mn Cast Alloys)

  • 이찬희;김경현;김인배
    • 한국재료학회지
    • /
    • 제11권4호
    • /
    • pp.266-271
    • /
    • 2001
  • Al-Cu-Mn 주조합금의 응력부식균열 저항성에 미치는 Cd첨가의 영향을 C-ring test와 전기전도도 시험을 통하여 조사하였다. Cd첨가량이 증가함에 따라 전기전도도가 증가하였고 SCC 저항성도 증가하였다. SCC 시험결과 균열이 입계를 따라 전파되는 입계파괴가 일어났으며, 파면은 취성파괴양상을 나타내었고, 입계를 따라 조대 석출물과 무석출대가 나타난 것으로 보아서 이 합금의 SCC 기구는 anodic dissolution model이라고 판단된다. Cd을 첨가하지 않은 경우 최대경도값은 127Hv였으나, Cd을 첨가한 경우 최대경도값은 138∼146Hv로 증가하였다.

  • PDF

Cd처리가 느타리버섯 균사체 생장에 미치는 영향 (Effect of Cd treatment on the mycelial growth of Pleurotus ostreatus)

  • 박윤진;김태권;조용구;장명준
    • 한국버섯학회지
    • /
    • 제18권1호
    • /
    • pp.79-83
    • /
    • 2020
  • In this study, we determined the effect of different concentrations of Cd on the growth of Pleurotus ostreatus mycelia, which was confirmed using PDA, PDB, and a column test. The efficacy of treatment was evaluated using Cd at two concentrations, 10 ppm and 100 ppm. The extent of mycelial growth on PDA and PDB was similar to that observed in the untreated groups and those treated with 10 ppm Cd. However, it was found that the mycelial growth was suppressed in a system treated with Cd at concentrations of 100 ppm. Moreover, the extent of mycelial growth observed upon conducting a column test was similar to that obtained using PDA and PDB. When the composition of free amino acids in PDB was determined, their levels in the group treated with 100 ppm Cd were found to be similar to those of the control. However, the amounts of 15 amino acids in the group treated with 10 ppm of Cd had increased compared to those detected in the control.