• Title/Summary/Keyword: CC14

Search Result 405, Processing Time 0.029 seconds

Repair of Large Spinal Soft Tissue Defect Resulting from Spinal Tuberculosis Using Bilateral Latissimus Dorsi Musculocutaneous Advancement Flap: A Case Report (척추결핵으로 인한 광범위한 결손에 대해 양측 넓은등근전진피판술을 이용한 치험례)

  • Kim, Yeon-Soo;Kim, Jae-Keun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.695-698
    • /
    • 2011
  • Purpose: Since spinal tuberculosis is increasing in prevalence, it appears that a repair of spinal soft tissue defect as a complication of spinal tuberculosis can be a meaningful work. We report this convenient and practical reconstructive surgery which use bilateral latissimus dorsi musculocutaneous advancement flap. Methods: Before the operation, $13{\times}9.5$ cm sized skin and soft tissue defect was located on the dorsal part of a patient from T11 to L3. And dura was exposed on L2. Under the general endotrachel anesthesia, the patient was placed in prone position. After massive saline irrigation, dissection of the bilateral latissimus dorsi musculocutaneous flaps was begun just upper to the paraspinous muscles (at T11 level) by seperating the paraspinous muscles from overlying latissimus dorsi muscles. The plane between the paraspinous muscles fascia and the posterior edge of the latissimus dorsi muscle was ill-defined in the area of deformity, but it could be identified to find attachment of thoracolumbar fascia. The seperation between latissimus dorsi and external oblique muscle was identified, and submuscular plane of dissection was developed between the two muscles. The detachment from thoracolumbar fascia was done. These dissections was facilitated to advance the flap. The posterior perforating vasculature of the latissimus dorsi muscle was divided when encountered approximately 6 cm lateral to midline. Seperating the origin of the latissimus dorsi muscle from rib was done. The dissection was continued on the deep surface of the latissimus dorsi muscle until bilateral latissimus dorsi musculocutaneous flaps were enough to advance for closure. Once this dissection was completely bilateraly, the bipedicled erector spinae muscle was advanced to the midline and was repaired 3-0 nylon to cover the exposed vertebrae. And two musculocutaneous units were advanced to the midline for closure. Three 400 cc hemovacs were inserted beneath bilateral latissimus dorsi musculocutaneous flaps and above exposed vertebra. The flap was sutured with 3-0 & 4-0 nylon & 4-0 vicryl. Results: The patient was kept in prone and lateral position. Suture site was stitched out on POD14 without wound dehiscence. According to observative findings, suture site was stable on POD55 without wound problem. Conclusion: Bilateral latissimus dorsi musculocutaneous advancement flap was one of the useful methods in repairing of large spinal soft tissue defect resulting from spinal tuberculosis.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

STUDIES ON THE PROPAGATION OF ABALONE (전복의 증식에 관한 연구)

  • PYEN Choong-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.3
    • /
    • pp.177-186
    • /
    • 1970
  • The spawning of the abalone, Haliotis discus hannai, was induced In October 1969 by air ex-position for about 30 minutes. At temperatures of from 14.0 to $18.8^{\circ}C$, the youngest trochophore stage was reached within 22 hours after the egg was laid. The trochophore was transformed into the veliger stage within 34 hours after fertilization. For $7\~9$ days after oviposition the veliger floated in sea water and then settled to the bottom. The peristomal shell was secreted along the outer lip of the aperture of the larval shell, and the first respiratory pore appears at about 110 days after fertilization. The shell attained a length of 0.40 mm in 15 days, 1.39 mm in 49 days, 2.14 mm in 110 days, 5.20 mm in 170 days and 10.00 mm in 228 days respectively. Monthly growth rate of the shell length is expressed by the following equation :$L=0.9981\;e^{0.18659M}$ where L is shell length and M is time in month. The density of floating larvae in the culture tank was about 10 larvae per 100 co. The number of larvae attached to a polyethylene collector ($30\times20\;cm$) ranged from 10 to 600. Mortality of the settled larvae on the polyethylene collector was about $87.0\%$ during 170 days following settlement. The culture of Nauicula sp. was made with rough polyethylene collectors hung at three different depths, namely 5 cm, 45 cm and 85 cm. At each depth the highest cell concentration appeared after $15\~17$ days, and the numbers of cells are shown as follows: $$5\;cm\;34.3\times10^4\;Cells/cm^2$$ $$45\;cm\;27.2\times10^4\;Cells/cm^2$$ $$85\;cm\;26.3\times10^4\;Cells/cm^2$$ At temperatures of from 13.0 to $14.3^{\circ}C$, the distance travelled by the larvae (3.0 mm In shell length) averaged 11.36 mm for a Period of 30 days. Their locomation was relatively active between 6 p.m. and 9 p.m., and $52.2\%$ of them moved during this period. When the larvae (2.0 mm in shell length) were kept in water at $0\;to\;\~1.8^{\circ}C$, they moved 1.15cm between 4 p.m. and 8 p.m. and 0.10 cm between midnight and 8 a.m. The relationships between shell length and body weight of the abalone sampled from three different localities are shown as follows: Dolsan-do $W=0.2479\;L^{2.5721}$ Huksan-do $W=0.1001\;L^{3.1021}$ Pohang $W=0.9632\;L^{2.0611}$

  • PDF

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.

Effects of Partial Cervus elaphus Linne' Extract on Antitumoral Immune Response in Melanoma-induced Mice (부위별(部位別) 녹용(鹿茸)이 흑색종(黑色腫) 유발(誘發) 생쥐의 종양억제(腫瘍抑制)와 면역기능(免疫機能)에 미치는 영향(影響))

  • Oh Ha-Souk;Kim Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.39-78
    • /
    • 2000
  • Introduction: In order to investigate the effects of partial Cervus elaphus Linne' extract on antitumoral immunological, a group of mice are melanoma-induced and observed reponses in terms of the number of lymphocyte, CD4+ count, CD8+ count, CD4+/CD8+ ratio in blood and spleen, change in body weight, melanoma weight, spleen index, NK cell activity and productivity of IL-2 in each mouse Methodology: Male C57BL/6 mice were chosen as an experimental object and were divided into 5 groups randomly selection. The normal group did not receive any induction. The control group was treated with normal saline in melanoma-induced' mice. Sample I group induced the upper part of Cervus elaphus Linne' extract in melanoma-induced mice. Sample II group was induced the middle part of Cervus elaphus Linne' extract in melanoma-induced mice. Sample III group was induced the lower part of Cervus elaphus Linne' extract in melanoma-induced mice. The dosage of medication was 0.2cc daily for 14days. Results: 1. There was a significant difference in the number of lymphocyte in spleen in the sample I (upper part of Cervus elaphus Linne' extract induced) and the sample II (middle part of Cervus elaphus Linne' extract induced) compared to the control group and the sample III (lower part of Cervus elaphus Linne' extract induced). On the other hand, no significant difference was observed in the number of lymphocyte in blood in the control group and all sample groups. 2. In the CD4+ T cell ratio in blood, all three sample groups showed differences compared to the control group, though there was no significant difference between sample groups. In the CD4+ T cell ratio in spleen, there was a difference between the sample I and the control group, while the sample II and the sample III had significant difference to the control group. And also, it has been observed there were differences between the sample I and the other samples. 3. In the CD8+ T cell ratio in spleen, all three sample groups showed significant differences compared to the control group, while there was no difference between groups in the ratio in blood. 4. In the CD4+/CD8+ T cell ratio in blood, the sample I showed a significant difference compared to the control group, while the sample 1I and sample III showed differences compared to the control group. In the CD4+/CD8+ T cell ratio in spleen, all three samples showed a significant difference compared to the control group, when the sample I had a difference to the other sample groups. 5. The spleen index of the sample I and the sample II showed a significant difference compared to the sample III and the control group. In comparison between the sample groups, the sample I and the sample II showed a significant difference to the sample III. 6. In terms of the change in body weight and melanoma weight, all three sample groups showed a significant difference compared to the control group, while the comparison between the sample groups showed the sample and the sample II had a significant difference to the sample Ⅲ. 7. In comparison of NK cell activity, the sample I had a difference compared to the other groups when the effector to target cell ratio was 2.5:1. With the ratio of 5:1, the sample I and sample II showed significant differences compared to the control group, while the sample Ⅲ showed a difference. When the effector to target cell ratio was 10:1, there was no difference between groups. 8. In the productivity of IL-2, all three sample groups showed significant differences compared to the control group. In comparison between sample groups, there were significant differences between each sample groups in order of the sample I , the sample II and the sample Ⅲ. Conclusion: As one can witness from the above results, administration of partial Cervus elaphus Linne extract played important role in antitumoral immune response in melanoma-induced mice, and it could be suggested that sample I and sample II groups have prominent antitumoral immune effect.

  • PDF

철도기준점을 이용한 철도중심선형 좌표변환에 관한연구 - 호남고속철도 계획노선을 중심으로 -

  • Moon, Cheung-Kyun;Heo, Joon;Kang, Sang-Du;Kim, Sang-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1141-1151
    • /
    • 2007
  • In this paper through Honam high-speed railroad which is planned with the north and south axis, we will verify the feasibility of the coordinate conversion using railroad control points after regarding current planned-railroad as the linear central axises. From analysis, distortion of Y axis varies 21cm to 40cm diminishing to a gentle straight line, distortion of X axis varies 14cm to 29cm. Through a revision, the deviation value between the coordinates were 6mm to 9mm and it satisfied the allowable error of national geographic information institute which is following ITRF (International Terrestrial Reference Frame) and cadastral boundary survey(10cm). consequently the coordinate conversion is possible using railroad control points as common control points.

  • PDF

Susceptibility Loci Associations with Prostate Cancer Risk in Northern Chinese Men

  • Wang, Na-Na;Xu, Yong;Yang, Kuo;Wei, Dong;Zhang, Yao-Guang;Liu, Ming;Shi, Xiao-Hong;Liang, Si-Ying;Sun, Liang;Zhu, Xiao-Quan;Yang, Yi-Ge;Tang, Lei;Zhao, Cheng-Xiao;Wang, Xin;Chen, Xin;Hui, Juan;Zhang, Yu-Hong;Zhu, Ling;Yang, Fan;Zhang, Yu-Rong;Yang, Ze;Wang, Jian-Ye
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3075-3078
    • /
    • 2013
  • Background: KLK3 gene products, like human prostate-specific antigen (PSA), are important biomarkers in the clinical diagnosis of prostate cancer (PCa). G protein-coupled receptor RFX6, C2orf43 and FOXP4 signaling plays important roles in the development of PCa. However, associations of these genes with PCa in northern Chinese men remain to be detailed. This study aimed to investigate their impact on occurrence and level of malignancy. Methods: All subjects were from Beijing and Tianjin, including 266 cases with prostate cancer and 288 normal individuals as controls. We evaluated associations between clinical covariates (age at diagnosis, prostate specific antigen, Gleason score, tumor stage and aggressive) and 6 candidate PCa risk loci, genotyped by PCR- high resolution melting curve and sequencing methods. Results: Case-control analysis of allelic frequency of PCa associated with PCa showed that one of the 6 candidate risk loci, rs339331 in the RFX6 gene, was associated with reduced risk of prostate cancer (odds ratio (OR) = 0.73, 95% confidence interval (CI) =0.57-0.94, P = 0.013) in northern Chinese men. In addition, subjects with CX (CC+TC) genotypes had a decreased risk for prostrate cancer compared to those carrying the TT homozygote (OR =0.64, 95% CI = 0.45- 0.90, P = 0.008). The TT genotype of 13q22 (rs9600079, T) was associated with tumor stage (P=0.044, OR=2.34, 95% CI=0.94-5.87). Other SNPs were not significantly associated with clinical covariates in prostate cancer (P > 0.05). Conclusions. rs339331 in the RFX6 gene may be associated with prostate cancer as a susceptibility locus in northern Chinese men.

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.