• Title/Summary/Keyword: CC 평가

Search Result 421, Processing Time 0.027 seconds

Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography (유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가)

  • Uhm, Hyon-Ja;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

Proposal of Flooding Time Nomograph (FTN) for Prediction of Flood Occurrence Time in Urban Stream: A Case Study of Dorimcheon Basin (도시하천의 홍수발생시간 예측을 위한 Flooding Time Nomograph (FTN) 제안: 도림천 유역을 중심으로)

  • Moon, Hyeon-Tae;Yoon, Sun-Kwon;Yoon, Jun-Seo;Moon, Young-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.345-345
    • /
    • 2022
  • 기후변화의 영향으로 도시하천의 홍수피해가 증가추세이며, 여름철 돌발호우 발생으로 하천내 고립사고 피해가 빈번히 발생하고 있다. 특히 중·소규모 도시하천은 홍수유출 도달시간이 매우 짧고 수위가 급격히 상승하여 돌발호우에 매우 취약하므로, 정확한 홍수발생 가능성 및 시점 예측을 통한 신속한 홍수 예·경보가 필요하다. 따라서 본 연구에서는 강우강도, 강우시간분포, 강우지속시간 등에 따른 홍수발생여부 뿐만 아니라 홍수발생시간을 예측할 수 있는 Flooding Time Nomograph (FTN)를 개발하였다. 본 연구의 대상유역은 도림천 유역으로, FTN 개발을 위하여 도시하천의 강우-유출모의에 적합한 XP-SWMM 모형을 구축하여 활용하였다. 또한 Huff의 4분위 강우분포를 이용한 다양한 형태의 가상 강우시나리오를 설정하여 강우유출모의를 수행하였으며, 모의결과를 기반으로 강우강도와 홍수발생시간의 관계식을 산정하여 FTN을 생성하였다. 실제 호우 사상에 대한 관측 홍수발생시간과의 비교를 통해 FTN의 적용성을 평가한 결과, 상관계수 CC=0.8, NSE=0.6 이상으로 높은 정확도를 보이는 것으로 나타났으며, 강우발생 시 둔치수위 도달 홍수위 기준 최대 30분의 사전 대피시간 확보가 가능함을 확인하였다. 따라서 본 연구에서 개발한 FTN을 이용한 도시하천의 홍수 예·경보 시스템 구축의 경우, 강우정보에 따른 홍수발생여부 및 홍수발생시간을 합리적으로 판단할 수 있어, 둔치 수위 예·경보 등 보다 신속한 상황대응이 가능할 것으로 사료된다.

  • PDF

Evaluation of Fracture Toughness Characteristics of Pultruded CFRP Spar-Cap Materials with Non-woven Glass Fabric for Wind Blade (유리섬유 부직포가 삽입된 풍력 블레이드 인발 성형 스파캡 소재의 파괴인성 특성 평가)

  • Young Cheol Kim;Geunsu Joo;Jisang Park;Woo-Kyoung Lee;Min-Gyu Kang;Ji Hoon Kim
    • Journal of Wind Energy
    • /
    • v.14 no.3
    • /
    • pp.83-90
    • /
    • 2023
  • The purpose of this study is to evaluate the inter-laminar fracture toughness characteristics of CFRP pultrusion spar cap materials reinforced with non-woven glass fabric. Test specimens were fabricated by the infusion technique. A non-woven glass fabric and artificial defects were embedded on the middle surface between two pultruded CFRP panels. Double cantilever beam (DCB) and End Notched Flexure (ENF) tests were performed according to ASTM standards. Fracture toughness and crack propagation characteristics were evaluated with load-displacement curves and delamination resistance curves (R-Curve). The fracture toughness results were calculated by compliance calibration (CC) method. The initiation and propagation values of Mode-I critical strain energy release rate value GIc were 1.357 kJ/m2 and 1.397 kJ/m2, respectively, and Mode-II critical strain energy release rate values GIIc were 4.053 kJ/m2 for non-precracked test and 4.547 kJ/m2 for precracked test. It was found that the fracture toughness properties of the CFRP pultrusion spar-cap are influenced by the interface between the layers of CFRP and glass fiber non-woven.

Analysis of dosimetric leaf gap variation on dose rate variation for dynamic IMRT (동적 세기조절방사선 치료 시 선량률 변화에 따른 선량학적엽간격 변화 분석)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • To evaluate the position accuracy of the MLC. This study analyzed the variations of the dosimetric leaf gap(DLG) and MLC transmission factor to reflect the location of the MLC leaves according to the dose rate variation for dynamic IMRT. We used the 6 MV and 10 MV X-ray beams from linear accelerator with a Millennium 120 MLC system. We measured the variation of DLG and MLC transmission factor at depth of 10 cm for the water phantom by varying the dose rate to 200, 300, 400, 500 and 600 MU/min using the CC13 and FC-65G chambers. For 6 MV X-ray beam, a result of measuring based on a dose rate 400 MU/min by varying the dose rate to 200, 300, 400, 500 and 600 MU/min of the difference rate was respectively -2.59, -1.89, 0.00, -0.58, -2.89%. For 10 MV X-ray beam, the difference rate was respectively ?2.52, -1.69, 0.00, +1.28, -1.98%. The difference rate of MLC transmission factor was in the range of about ${\pm}1%$ of the measured values at the two types of energy and all of the dose rates. This study evaluated the variation of DLG and MLC transmission factor for the dose rate variation for dynamic IMRT. The difference of the MLC transmission factor according to the dose rate variation is negligible, but, the difference of the DLG was found to be large. Therefore, when randomly changing the dose rate dynamic IMRT, it may significantly affect the dose delivered to the tumor. Unless you change the dose rate during dynamic IMRT, it is thought that is to be the more accurate radiation therapy.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry (소조사면에서의 불균질 물질 보정 계산의 평가)

  • Shin, Hun-Joo;Kang, Young-Nam;Jang, Ji-Sun;Seo, Jae-Hyuk;Jung, Ji-Young;Choi, Byung-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.

  • PDF

Treatment of Refractory Lateral Epicondylitis with Platelet-Rich Plasma (불응성 주관절 외상과염에 대한 혈소판 풍부 혈장 주입 치료의 임상적 결과)

  • Ko, Sang-Hoon;Lee, Chae-Chil;Kang, Byeong-Seong;Lee, Ki-Jae;Lee, Seon-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • Purpose: To evaluate clinical results of a single percutaneous injection of platelet-rich plasma in patients with refractory lateral epicondylitis. Materials and Methods: Between Jan and Dec 2009, fifteen patients (5 male, 10 female) received a diagnosis of lateral epicondylitis of the elbow and were evaluated in this study. Their average age was 43.5 years. All patients were initially given a variety of non-surgical treatments for more than 1year. All patients were considering surgery. These patients were given a single percutaneous injection of 3cc of platelet-rich plasma. To assess pain, we used a visual analogue scale (VAS) at rest and during work & the Patient-Rated Tennis Elbow Evaluation (PRTEE) score. We compared the score before treatment with scores 4 and 12 weeks after treatment. Results: Average VAS scores at rest improved from 4.6 before treatment to 2.5 at week 4, and 1.8 at week 12. The average VAS score while working also improved from 7.8 before treatment to 6.2 at week 4, and 4.25 at week 12. The average PRTEE score improved from 60.13 before treatment to 46.12 at week 4 and 24.6 at week 12. Conclusion: Treatment using a single percutaneous injection of platelet-rich plasma in patients with refractory lateral epicondylitis appears to be an effective treatment modality. Platelet-rich plasma should be considered before surgical intervention.

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Evaluation of Embolization Effect of Hepatocellular Carcinoma by Hepatic Arterial Flow Study with $^{99m}Tc$-MAA SPECT (간암에서 색전술의 효과를 평가하는데 있어서 $^{99m}Tc$-MAA SPECT를 이용한 간동맥 혈류 검사의 의의)

  • Lee, Byung-Hee;Yoo, Hyung-Sik;Lee, Jong-Doo;Chung, Jin-Ill;Park, Chang-Yun;Lee, Jong-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.62-68
    • /
    • 1994
  • This study was aimed to compare the density of the functional microcirculation of hepatocellular carcinoma (HCC) with normal liver and to investigate the effect of hepatic-arterial oily chemoembolization (HAE) by radionuclide examination. Methods : Eight patients with HCC proven by biopsy in five, and clinically and radiologically in three were included. The mixture of 2 cc normal saline with three to four mCi of $^{99m}Tc$-MAA was infused through a hepatic-arterial catheter for a minute. Dynamic images were obtained at a rate of 4 sec per frame for a minute, and static images and SPECT were followed. Results : In three patients who underwent hepatic arterial angiography (HAA) alone, radioactivity was markedly increased in tumors compared to the adjacent liver immediately after infusion of $^{99m}Tc$-MAA. The ratios of tumoral and extratumoral up-take (T/E ratio) were above 6.5 (range; $6.5{\sim}l9$, mean; 12.5). In four of the five patients who under-went superselective HAE, T/E ratio were remark-ably decreased ($0.5{\sim}1.3$). The areas of embolization were better delineated in radionuclide study than in postembolization HAA. In the other one who was considered to be embolized completely on HAA, strong radiouptake in the tumor was disclosed (T/E ratio; 7.0). Conclusions : Therefore hepatic-arterial flow study with radionuclide imaging using $^{99m}Tc$-MAA can be a valuable method to assess the accurate embolization effect in HCC.

  • PDF