• Title/Summary/Keyword: CC평가

Search Result 421, Processing Time 0.032 seconds

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

Thermal Characterization and Analysis of High Power Ceramic LED Package (고출력 세라믹 LED 패키지의 방열 특성 평가 및 해석 연구)

  • Cho, Hyun-Min;Choi, Won-Kil;Jung, Bong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.315-316
    • /
    • 2009
  • 본 논문에서는 1W 급 이상의 고출력 LED 용 패키지로서 세라믹 LTCC 적층 패키지의 방열 특성을 평가하고 열해석 결과와의 차이에 대해 고찰하였다. 특히, 세라믹 패키지의 방열 특성을 향상시키기 위해 Thermal Via와 Heat slug를 LED Chip 하단부에 위치시켰을 때 방열 특성을 평가하기 위해 Transient Thermal Test를 이용하여 각각의 경우에 대한 열저항을 평가하여 방열 특성의 항상 정도를 확인하였으며, 열해석 시뮬레이션을 통해 얻은 결과와 비교하였다. 평가 결과 Heat slug를 배치한 패키지가 열저항이 $8^{\circ}C/W$로서 가장 우수한 특성을 보여주었으며, 열해석 결과와의 차이에 대해서는 광출력으로 방출된 전력을 계산하여 보정함으로써 $1^{\circ}C$ 이하의 편차를 보여주는 결과를 얻을 수 있었다.

  • PDF

The Implementation of SEED Cipher Algorithm Test Module Applied CMVP Test (CMVP 테스트를 적용한 SEED 암호 알고리즘 모듈 구현)

  • Park, Seong-Gun;Jeong, Seong-Min;Seo, Chang-Ho;Kim, Il-Jun;Shin, Seung-Jung;Kim, Seok-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05c
    • /
    • pp.1937-1940
    • /
    • 2003
  • 정보보호 평가는 크게 시스템 평가인 CC(Common Criteria)평가와 암호모듈 평가인 CMVP(Cryptographic Module Validation Program)평가로 나눌 수 있다. 본 논문은 국내 표준 암호 알고리즘 SEED를 북미의 CMVP의 3가지 블록 알고리즘 시험방법인 KAT(Known Answer Test), MCT(Monte C미개 Test), MMT(Multi-block Message Test)를 JAVA환경에 적용하여 시범 구현하였다. 테스트 방법으로 CMVP의 MOVS, TMOVS, AESAVS를 선정하여 FIPS 표준을 적용하였다. 구현 환경으로는 JCE기반의 Cryptix를 채택하여 CMVP의 블록 암호 알고리즘 테스트 시스템 중 일부를 구현하였다.

  • PDF

Development of evaluation factors for SW education in elementary and secondary schools (초·중등 SW교육의 평가요소 개발)

  • Park, Juyeon;Kim, Jonghye;kim, Sughee;Lee, HyunSook;Kim, Soohwan
    • The Journal of Korean Association of Computer Education
    • /
    • v.20 no.6
    • /
    • pp.47-59
    • /
    • 2017
  • The Goal of SW education is to cultivate creative and convergent human resources with computational thinking ability. The content and methods of SW education are diverse, and it is difficult for the students to properly evaluate what they have learned. In order to appropriately evaluate the learning contents, SW education evaluations should be able to easily evaluate the core content of the SW education. The purpose of this study is to provide a systematic framework that can be used to develop evaluation factors to evaluate the effectiveness of SW education in elementary and secondary schools. We conducted a literature review, a field suitability review through FGI, an expert consultation, and a Delphi survey. As a result, the metrics of the cognitive domain were developed with 17 keywords in three categories: Computational Materials & Outputs (CMO), Computational Concepts (CC), and Computational Practices (CP). Also, metrics of the affective domain were developed with 13 sub-areas in four categories: value, attitude, computational thinking efficacy, and interest. The SW education evaluation factors developed in this study can be used as a framework to develop the evaluation contents in accordance with the contents of education.

Effect of Calcium Extracted from Salted Anchovy (Engraulis japonicus) on Calcium Metabolism of the Rat (멸치젓에서 추출한 칼슘이 흰쥐의 칼슘대사에 미치는 영향)

  • Kim, Hyang Suk;Choi, Eun Ok;Kim, Man Do;Choi, Yung Hyun;Kim, Byung Woo;Kim, Soo Yeon;Hwang, Hye Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.2
    • /
    • pp.182-187
    • /
    • 2013
  • This study was conducted to examine the effect of calcium extracted from salted anchovy (Engraulis japonicus) on the calcium metabolism of rats. Sprague-Dawley male rats were fed low-calcium diets (0.15%) for 2 weeks after the adjustment period. Rats were divided into five groups and were fed experimental diet for four weeks. Experimental diets were low calcium (LC, 0.15% $CaCO_3$), 0.5% $CaCO_3$ (CC), seaweed calcium (SC), calcium lactate (LC), anchovy calcium (AC). The low-calcium diet group (LC) showed the lowest weight gain and had no differences among the groups with adequate calcium intake. Calcium retention was lowest in the LC group and higher in the CL, SC, AC groups than in SC groups. Serum alkaline phosphatase (ALP) level was highest in LC group, and significantly low in the CC and AC groups (p<0.05). Parathyroid hormone and osteocalcin levels showed no differences among experimental groups. The urine deoxypyridinoline (DPD) level was lower in AC and CC groups compared to the LC group (p<0.05). The dry weight of the femur showed no significant differences among normal calcium groups. The bone mineral density of the femur in AC and CC group were significantly higher than the LC group (p<0.05). From these results, calcium extracted from salted anchovy can be useful as a calcium supplement comparable with calcium carbonate.

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

A Case Study on Applying Common Criteria to improve security of Software Products (소프트웨어 제품 보안성 개선을 위한 공통평가기준 적용사례)

  • Kim, Sang-He;Leem, Choon-Seong;Kim, Jae-Sung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11c
    • /
    • pp.1747-1750
    • /
    • 2003
  • IT 제품 및 시스템의 보안성 평가를 위한 국제표준(ISO/IEC15408)인 공통평가기준(CC)은 해당 평가 보증등급(EAL, Evaluation Assurance Level)의 요구사항에 따라 평가대상 제품(TOE, Target of Evaluation), 제품의 개발 및 운영 문서를 포함하는 평가제출물을 요구하고 있다. 개발자가 공통평가기준을 적용하여 제품의 보안성을 개선하고 성공적으로 평가인증서를 받기 위해서는 상당한 노력이 요구된다. 대부분의 개발자는 제품 개발 완료 후 제품의 보안성을 검토하고 평가를 준비하므로 리엔지니어링 등 추가적인 비용과 시간을 투입해야 하는 문제가 있다. 본 논문에서는 BSD(Berkeley Software Distributions) 4.4 기반의 운영체제인 MTOS(Mitretek)를 개발한 사례를 통하여 개발과정과 요구사항 및 평가준비를 위한 평가제출물 작성과의 연계성을 제시하였다. 개발자는 본 논문에서 제시한 연계성을 활용하여 소프트웨어 제품의 개발과정에 공통평가기준을 적용하여 제품의 보안성을 제고하고 보안성 평가를 준비하는데 시간과 노력을 절감할 수 있다.

  • PDF

Complexity Metrics for Analysis Classes in the Unified Software Development Process (Unified Process의 분석 클래스에 대한 복잡도 척도)

  • 김유경;박재년
    • The KIPS Transactions:PartD
    • /
    • v.8D no.1
    • /
    • pp.71-80
    • /
    • 2001
  • Object-Oriented (OO) methodology to use the concept like encapsulation, inheritance, polymorphism, and message passing demands metrics that are different from structured methodology. There are many studies for OO software metrics such as program complexity or design metrics. But the metrics for the analysis class need to decrease the complexity in the analysis phase so that greatly reduce the effort and the cost of system development. In this paper, we propose new metrics to measure the complexity of analysis classes which draw out in the analysis phase based on Unified Process. By the collaboration complexity, is denoted by CC, we mean the maximum number of the collaborations can be achieved with each of the collaborator and detennine the potential complexity. And the interface complexity, is denoted by IC, shows the difficulty related to understand the interface of collaborators each other. We prove mathematically that the suggested metrics satisfy OO characteristics such as class size and inheritance. And we verify it theoretically for Weyuker' s nine properties. Moreover, we show the computation results for analysis classes of the system which automatically respond to questions of the it's user using the text mining technique. As we compared CC and IC to CBO and WMC, the complexity can be represented by CC and IC more than CBO and WMC. We expect to develop the cost-effective OO software by reviewing the complexity of analysis classes in the first stage of SDLC (Software Development Life Cycle).

  • PDF

Relationship between Physical Properties and Sensibility Obtained from the Rustling Sounds of Silk Fabrics and Their Transformed Colors (실크 직물의 스치는 소리와 변환된 색채의 물리량과 감성간의 관계)

  • 김춘정;최계연;김수아;조길수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.1-4
    • /
    • 2001
  • 본 연구에서는 실크 직물 7종의 마찰음을 녹음한 후, 색채 변환시켜 소리와 변환색채에 e한 감성을 평가함으로써 시각과 청각을 만족시킬 수 있는 의류소재 개발에 대한 기초자료를 제공하고자 하였다. 피험자 30명을 대상으로 소리와 변환색채를 차례로 제공한 후 감성을 평가하도록 하였다. 물리량은 소리의 경우 LPT, $\Delta$L, $\Delta$f, ARC를 색채의 경우 RP, GP, BP, CC를 계산하여 감성과의 관계를 조사하였다. 소리와 색채에 대한 감성차원으로는 '우아함', '활동감', '터프함'의 세요인이 도출되었다. 각 감성차원에 대한 소리와 색채 물리량과의 관계를 살펴보면, LPT와 $\Delta$L이 작을수록, 홍색비율이 크고 색채빈도수가 적을수록 우아함차원으로 평가하였으며, LPT와 $\Delta$L의 값이 클수록, 녹색비율이 크고 색채빈도수가 많을수록 활동감차원으로 평가하였다. 또한 ARC값이 작을수록, 홍색비율이 클수록 터프함차원으로 나타났다. 직물별 소리와 색채에 대한 선호도는 전통적인 수자직 직물이 가장 높게 나타났다.