• Title/Summary/Keyword: CAM System

Search Result 1,015, Processing Time 0.025 seconds

Comparison of marginal gap of monolithic CAD/CAM-generated crowns according to the ceramic materials for CEREC system (CEREC system에서 사용하는 세라믹 소재로 가공된 CAD/CAM 전부도재관의 변연간격 비교분석)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.119-125
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the marginal gap of all-ceramic crowns fabricated by CEREC$^{(R)}$ in-office CAD/CAM system. Methods: The mandibular first molar was selected as the abutment for the experiments. Thirty working models were prepared. VITA Mark II(VM) and VITA Enamic(VE), LAVA Ultimate(LU) blocks were milled using CEREC MCXL with CEREC 3D system to construct 10 crowns for each groups. To measure marginal gap, milled restorations were examined under digital microscope with scale under 160x magnifications. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There was no significant difference in the marginal gap regarding to ceramic materials(p>0.05). Conclusion: Single crowns fabricated using CEREC in-office CAD/CAM system provided clinically acceptable marginal gap. This confirmed that the type of ceramic material used does not determine the precision of fit of a prosthesis.

The use of complementary and alternative medicine in children with common neurologic diseases

  • Yeon, Gyu-Min;Nam, Sang Ook
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.8
    • /
    • pp.313-318
    • /
    • 2016
  • Complementary and alternative medicine (CAM) is a phrase used to describe additional health care methods such as mind/body practices and natural products not regarded as treatments by conventional medicine. The use of CAM in children with common neurologic diseases is more frequent than its use in healthy children (24%-78% vs. 12%). However, less than half of patients report such use to their physicians. The preferred modalities of CAM vary in different countries due to their different cultures and traditions. The most common factor significantly associated with the use of CAM is parental CAM use in most studies. The frequency of the use of CAM in children and adults with neurologic diseases is similar, and both rates are higher than the rates in those without these conditions. The preferred modalities of CAM in adults are diverse, and megavitamins and mind/body therapy (prayer and chiropractic care) are included. The most common factor significantly associated with the use of CAM in adults with neurologic diseases is high educational level. Physicians need to be concerned with patients' use of CAM and provide correct information about CAM so that patients may make the right decisions. Further study is needed to determine the evidence-based efficacy of CAM use in children with common neurologic diseases.

A Study on Optimum Cam Profile Extraction Considering Dynamic Characteristics of a Cam-Valve System (밸브 기구의 동특성을 고려한 캠 형상 설계에 관한 연구)

  • 박경조;전혁수;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.29-39
    • /
    • 1989
  • In this work, a numerical and experimental study was done to get an optimum cam profile considering dynamic characteristics of a cam-valve system. First of all, a four degree of freedom dynamic model was set up for an OHV type cam-valve acceleration while not modifying original cam shape greatly. Also another optimization which aims to enlarge the valve displacement area while reducing the peak valve acceleration, was tried. The optimized cam profile was tested experimentally and found that the measured valve displacement and pushrod force show only very small error from the analytically predicted model simulation results.

An Experimental Study on the Tappet Spin for a Direct Acting Valve Train System (직접 구동형 밸브 트레인 시스템의 태핏 회전에 관한 실험적 연구)

  • Cho, Myung-Rae;Kim, Hyung-Jun;Moon, Tae-Seon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1179-1184
    • /
    • 2003
  • The technique for measuring the rotational speed of tappet in direct acting type valve train system has been developed. The optic signal monitoring system with laser and optic fiber was designed to follow the signal of tappet rotation. The system was based on ON/OFF signal generation from the additional encoder teeth under the tappet with optic fibers attached photo transistor. The data showed that tappet rotation was affected by offset, oil temperature and cam shaft operating speed. Also it was found that tappet rotation increases with oil temperature. Tappet spin was delayed 10∼s20$^{\circ}$ cam angle after valve opening. The instantaneous rotational speed of tappet was reciprocal to cam shaft speed and the tappet and the cam angle ratio was located in the range of 0.1∼0.3.

Study on Development of Parallel-Typed Tilting Table and RAD Tool Program (병렬기구형 틸팅 테이블 및 RAD Tool 프로그램 개발에 관한 연구)

  • 김태성;박성민;원동희;이민기;박근우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.284-289
    • /
    • 2002
  • In this paper, we develop a six-axes machining center tool(MCT) and CAD/CAM system based RAD Tool Program. The MCT consists of two mechanical parts, i.e., a X-Y-Z Cartesian coordinate typed MCT and a parallel-typed tilting table. Kinematics and singularity are accomplished to design the parallel-typed tilting table, and RAD Tool Program Is developed for the six-axes MCT, which requires the commands of position as well as orientation for machining of complex shape. In RAD Tool, the CAD/CAM system has a tool path generator, NC code generator and a graphic simulator. This paper designs the parallel-typed tilting table to meet the desired specification and presents the results of CAD/CAM system based RAD Tool Program.

  • PDF

3-Dimensional Model using Feature Recognition Rules from Orthographic Views for CAD/CAM Interface (CAD/CAM 인터페이스를 위한 정사영도면의 형상인식을 이용한 3차원 모델링)

  • 정구섭;이형국;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.443-448
    • /
    • 1994
  • As a basic step of interfacing CAD and CAM, it is required to convert thedrawing data into manufacturing information automatically. In this study the developed system carries out feature recognition from the orthographic views of press mold containing various pockets. Using rhe recognized output data, 3 dimension- al model is built using ADS and AME in order to check the result of recognition. The system consists of 4 main parts, suchas, Preprocessing, Coordinate handling, Feature recognition and 3D-modeling. The system shows a good application example which can interface the design and manufacturing stage in CAD/CAM system on PC level

  • PDF

Understanding and trends of esthetic treatment in prosthodontics : part 2. Zirconia (심미보철 치료의 경향과 이해 : part 2. 지르코니아)

  • Kang, Jung-In;Heo, Yu-Ri;Lee, Myeong-Seon;Son, Mee-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.617-622
    • /
    • 2014
  • With the explosive increase of esthetic demands by patients, many dental materials for the esthetic restoration have been introduced. Recently, zirconia based restorations are using for the cases of single crown, bridges, implant prostheses etc. Zirconia have superior mechanical properties and biocompatibility. Owing to the properties of high strength, zirconia has to be manufactured by CAD/CAM system. Dental CAD/CAM system is a futuristic treatment and technical system which makes it possible to produce the precision and uniform prosthesis and also standardize the treatments. This article introduces the characteristics of zirconia, fabrication procedure using CAD/CAM system and procedure for the cementation of zirconia based restoration.

Development of a Dedicated CAM System for Human Bust Machining (흉상환조가공 전용 CAM 시스템 개발)

  • 정회민;박준철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.7-10
    • /
    • 2001
  • We have developed a prototype dedicated CAM system for machining a human bust that is not a relief. The input is STL file format, and the output is NC-codes for machining on a 3-axis general purpose CNC milling machine with an index table attached. Main modules are STL import, STL transformation, modeling jig/fixture, master model generation, and calculation of machining area. System architecture is proposed and main modules are briefly described. We adopted the angle between tool-axis and the surface normal vector to calculate machining area, and tested at several degrees.

  • PDF

A study on development of CAD/CAM system for plasma-arc cutting process (플래즈머 아크절단용 CAD/CAM 시스템 개발에 관한 여구)

  • 엄두간;노태정;한국찬;나석주;나규환
    • Journal of Welding and Joining
    • /
    • v.9 no.3
    • /
    • pp.52-61
    • /
    • 1991
  • In the recent years the computer-numerical controlled cutting process such as a plasma arc cutting and a laser cutting is widely applied to reduce the time and cost expense for generating NC part program of the parts to be cut. In the present study, a CAD system(C-CAD) was developed to generate automatically the NC part programs with CLDAT(Cutter Location Data)for the CNC plasma arc cutting system. The NC part programs are composed of the 2-dimensional drawing of the parts to be cut and the technological data. The shape data of the parts drawn in the Auto-CAD can be also used in the C-CAD, since the data file generated by the C-CAD is compatible with that by the Auto-CAD. In order to check its applicability, the C-CAD and CAM system were applied to cut the parts, and which showed the satisfactory results.

  • PDF

Study on Development of Parallel-Typed Tilting Table (병렬기구형 틸팅 테이블의 개발에 관한 연구)

  • Lee, Won-Chul;Kim, Tae-Sung;Park, Kun-Woo;Lee, Min-Ki
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.734-739
    • /
    • 2001
  • In this paper, we develop a six-axes machining center tool(MCT) and CAD/CAM system. The MCT consists of two mechanical parts, i.e., a X-Y-Z Cartesian coordinate typed MCT and a parallel-typed tilting table. Kinematics and singularity are accomplished to design the parallel-typed tilting table, and CAD/CAM system is developed for the six-axes MCT, which requires the commands of position as well as orientation for machining of complex shape. The CAD/CAM system has a tool path generator, a NC code generator and a graphic simulator. This paper designs the parallel-typed tilting table to meet the desired specification and presents the results of tool path, NC code and graphic simulation.

  • PDF