• Title/Summary/Keyword: CAD-CAM denture

Search Result 86, Processing Time 0.023 seconds

Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report (적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례)

  • Kim, Hyun-Ah;Lim, Hyun-Pil;Kang, Hyeon;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.483-489
    • /
    • 2019
  • With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.

Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review (국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰)

  • Yi, Yuseung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.370-378
    • /
    • 2021
  • Purpose. The purpose of this study was to evaluate the currently published literatures investigating the accuracy of computer-aided design and computer-aided manufacturing removable partial denture (CAD-CAM RPD) framework with different manufacturing techniques and methods. Materials and methods. A comprehensive search for literatures was conducted in PubMed database using specific keywords with the patient, intervention, comparison, and outcome (PICO) question, "Is there a difference in accuracy of RPD frameworks manufactured using digital workflow according to the manufacturing process and methods?" Results. A total of 7 articles were selected. Two studies compared intraoral scanning and laboratory scanning for RPD frameworks and had heterogenous results. In the studies using different manufacturing process, RPD frameworks had clinically acceptable accuracy in both subtractive and additive manufacturing. Polyetheretherketone (PEEK)-milled RPD frameworks showed higher fit accuracy than traditionally casted or 3D printed RPDs. Direct milling method showed a higher accuracy than indirect milling method. However, in rapid prototyping, indirect method showed higher accuracy than direct method. Conclusion. The RPD frameworks fabricated using CAD-CAM technology showed a clinically acceptable level of accuracy regardless of manufacturing process or techniques. Consistent results have not been reported regarding the digital impression methods, which were intra oral scanning or laboratory scanning, and further studies are needed.

Restoration of partial removable dental prosthesis after fabricating of surveyed crowns utilizing electronic surveying: a case report (전자 서베잉을 이용한 서베이드 크라운 제작 후 국소의치 수복: 증례보고)

  • Min, Byungkwee;Jun, Daejeon;Yang, Hongso;Park, Sangwon;Lim, Hyunpil;Yun, Kwidug;Park, Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.135-142
    • /
    • 2017
  • Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology (치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례)

  • Kim, Yuyeon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.330-338
    • /
    • 2022
  • For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Rehabilitation of edentulous maxilla with implant-supported milled bar overdenture using CAD/CAM customized abutment: A case report (CAD/CAM 맞춤형 지대주를 이용한 milled-bar 피개의치 증례)

  • Ji, Woon;Chang, Jae-Seung;Kwon, Joo-Hyun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • In patients with fully edentulous maxilla, fabrication of implant-supported overdenture can be a viable treatment option, when a minimum of six implants were strategically placed. Among several attachment systems used for implant-supported overdentures, milled-bars prevent rotational movement of denture, thus showing great stability, and have the advantage of splinting multiple implants with each other. In this case report, a milled-bar supported overdenture was fabricated for a patient suffering from condition of fully edentulous maxilla with severe ridge resorption in the anterior residual ridge. Seven implants composed of three different systems were effectively utilized by CAD/CAM customized abutment and cement-retained milled bar.

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

Fabrication of surveyed crown and repairing the artificial teeth for existing removable partial denture using digital technology: a case report (디지털 방식을 이용한 기존 국소의치 맞춤 보철 제작과 심미적인 인공치 수리 증례)

  • Ina Kim;Eunji Oh;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.82-90
    • /
    • 2024
  • It often happens that a removable partial denture needs to be repaired due to tissue changes in the remaining alveolar ridge, fracture of the denture, or fracture of the abutment tooth. There are several advantages to retrofitting a customized surveyed crown under the existing RPD. Retrofitting a crown to the RPD decreases the economic burden to the patient and avoids the need for several appointments to fabricate a new RPD. It is difficult for artificial teeth used to repair dentures due to fractured natural teeth to have a shape similar to that of natural teeth, and to repair aesthetic artificial teeth, it is necessary to manufacture customized artificial teeth similar to the shape of each patient's teeth. Recently, CAD/CAM technology has been used to fabricate customized prosthetics on existing RPD to achieve high retention and fitness accuracy, and by manufacturing customized artificial teeth, more aesthetic and harmonious artificial tooth repair is possible. This is a case in which a denture was repaired using a digital method to fabricate a customized prosthesis on an existing partial denture and customized artificial teeth that mirrored the adjacent dentition, saving time and cost, simplifying the process, and achieving aesthetically and functionally satisfactory results.