DOI QR코드

DOI QR Code

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology

치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례

  • Kim, Yuyeon (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center) ;
  • Lee, Younghoo (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center) ;
  • Hong, Seoung-Jin (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University) ;
  • Paek, Janghyun (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University) ;
  • Noh, Kwantae (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University) ;
  • Kim, Hyeong-Seob (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University) ;
  • Kwon, Kung-Rock (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University) ;
  • Pae, Ahran (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University)
  • 김유연 (경희대학교치과병원 보철과) ;
  • 이영후 (경희대학교치과병원 보철과) ;
  • 홍성진 (경희대학교 치과대학 치과보철학교실) ;
  • 백장현 (경희대학교 치과대학 치과보철학교실) ;
  • 노관태 (경희대학교 치과대학 치과보철학교실) ;
  • 김형섭 (경희대학교 치과대학 치과보철학교실) ;
  • 권긍록 (경희대학교 치과대학 치과보철학교실) ;
  • 배아란 (경희대학교 치과대학 치과보철학교실)
  • Received : 2022.07.08
  • Accepted : 2022.08.22
  • Published : 2022.10.31

Abstract

For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

과두 골절 및 형태 이상으로 인해 불안정한 하악 운동 및 비정상적인 안모를 갖는 무치악 환자의 경우 환자의 안정된 하악위를 찾는 것이 중요하다. 본 증례에서는 flat table 치료의치를 이용하여 환자의 안모개선, 하악 운동의 안정, 의치의 안정성이 향상시켰다. 또한 flat table 치료의치의 수직고경 및 구순 지지도를 유지하고자 CAD-CAM 기술을 이용하여 제작한 총의치 수복을 통해 환자의 불편감을 개선하는 양호한 결과를 얻었기에 이를 보고하는 바이다.

Keywords

References

  1. Choi KY, Yang JD, Chung HY, Cho BC. Current concepts in the mandibular condyle fracture management part I: overview of condylar fracture. Arch Plast Surg 2012;39:291-300. https://doi.org/10.5999/aps.2012.39.4.291
  2. Ellis E, Throckmorton GS. Treatment of mandibular condylar process fractures: biological considerations. J Oral Maxillofac Surg 2005;63:115-34. https://doi.org/10.1016/j.joms.2004.02.019
  3. Choi IH, Kim SA, Kim NH, Lee YS. Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption and condyle fracture using gothic arch tracing and closed mouth impression technique: A case report. J Korean Acad Prosthodont 2020;58:145-52. https://doi.org/10.4047/jkap.2020.58.2.145
  4. Inada M, Yamazaki T, Shinozuka O, Sekiguchi G, Tamamori Y, Ohyama T. Complete denture treatments for a cerebral palsy patient by using a treatment denture. A case report. J Med Dent Sci 2002;49:171-7.
  5. Watanabe Y. Observation of horizontal mandibular positions in an edentulous patient using a digital gothic arch tracer: a clinical report. J Prosthet Dent 2004;91:15-9. https://doi.org/10.1016/j.prosdent.2003.10.009
  6. Abe J. Clinical mandibular position of edentulous patient. The utility and clinical methods of treatment denture. Nippon Dent Rev 2001;61:109-16.
  7. Han SR, Jeong CM, Yun MJ, Huh JB, Lee SH, Lee HJ. Fabrication of dentures for a patient with unstable mandibular movements: A case report. J Korean Acad Prosthodont 2020;58:378-84. https://doi.org/10.4047/jkap.2020.58.4.378
  8. Kim JY, Park C, Vang MS, Yang HS, Lim HP, Park SW. Fabrication of complete dentures using treatment dentures for a patient with erratic mandibular movements: A case report. J Korean Acad Prosthodont 2015;53:359-65. https://doi.org/10.4047/jkap.2015.53.4.359
  9. McGarry TJ, Nimmo A, Skiba JF, Ahlstrom RH, Smith CR, Koumjian JH. Classification system for complete edentulism. The American College of Prosthodontics. J Prosthodont 1999;8:27-39. https://doi.org/10.1111/j.1532-849X.1999.tb00005.x
  10. Slade GD. Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol 1997;25:284-90. https://doi.org/10.1111/j.1600-0528.1997.tb00941.x
  11. Baba NZ, Goodacre BJ, Goodacre CJ, Muller F, Wagner S. CAD-CAM complete denture systems and physical properties: a review of the literature. J Prosthodont 2021;30:113-24. https://doi.org/10.1111/jopr.13243
  12. Cha HS, Park JM, Kim TH, Lee JH. Wear resistance of 3D-printed denture tooth resin opposing zirconia and metal antagonists. J Prosthet Dent 2020;124:387-94. https://doi.org/10.1016/j.prosdent.2019.09.004
  13. Ahn JJ, Huh JB, Choi JW. In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods. J Korean Acad Prosthodont 2019;57:110-7. https://doi.org/10.4047/jkap.2019.57.2.110